The impact of sampling time on peak capacity and analysis speed in on-line comprehensive two-dimensional liquid chromatography

被引:58
作者
Potts, Lawrence W. [1 ]
Stoll, Dwight R. [1 ]
Li, Xiaoping [2 ]
Carr, Peter W. [2 ]
机构
[1] Gustavus Adolphus Coll, Dept Chem, St Peter, MN 56082 USA
[2] Univ Minnesota, Dept Chem, Minneapolis, MN 55455 USA
基金
美国国家卫生研究院;
关键词
2DLC; LC x LC; 2D on-line comprehensive chromatography; Multidimensional separations; Optimization; Peak capacity; Under-sampling; Re-equilibration; Cycle times; Sampling times; Peptides; Gradient elution; Isocratic elution; PARALLEL FACTOR-ANALYSIS; GRADIENT ELUTION; GAS-CHROMATOGRAPHY; X GC; TEMPERATURE; SEPARATIONS; PERFORMANCE; RESOLUTION; COLUMNS; OPTIMIZATION;
D O I
10.1016/j.chroma.2010.07.009
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Comprehensive two-dimensional liquid chromatography (2DLC) offers a number of practical advantages over optimized one-dimensional LC in peak capacity and thus in resolving power. The traditional "product rule" for overall peak capacity for a 2DLC system significantly overestimates peak capacity because it neglects under-sampling of the first dimension separation. Here we expand on previous work by more closely examining the effects of the first dimension peak capacity and gradient time, and the second dimension cycle times on the overall peak capacity of the 2DLC system. We also examine the effects of re-equilibration time on under-sampling as measured by the under-sampling factor and the influence of molecular type (peptide vs. small molecule) on peak capacity. We show that in fast 20 separations (less than 1 h), the second dimension is more important than the first dimension in determining overall peak capacity and conclude that extreme measures to enhance the first dimension peak capacity are usually unwarranted. We also examine the influence of sample types (small molecules vs. peptides) on second dimension peak capacity and peak capacity production rates, and how the sample type influences ptimum second dimension gradient and re-equilibration times. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:5700 / 5709
页数:10
相关论文
共 50 条
[11]   Metabolomics: Current analytical platforms and methodologies [J].
Dunn, WB ;
Ellis, DI .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (04) :285-294
[12]   Theoretical advantages and drawbacks of on-line, multidimensional liquid chromatography using multiple columns operated in parallel [J].
Fairchild, Jacob N. ;
Horvath, Krisztian ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (34) :6210-6217
[13]   MULTIWAVELENGTH DETECTION AND REITERATIVE LEAST-SQUARES RESOLUTION OF OVERLAPPED LIQUID-CHROMATOGRAPHIC PEAKS [J].
FRANS, SD ;
MCCONNELL, ML ;
HARRIS, JM .
ANALYTICAL CHEMISTRY, 1985, 57 (08) :1552-1559
[14]   TWO-DIMENSIONAL SEPARATIONS - CONCEPT AND PROMISE [J].
GIDDINGS, JC .
ANALYTICAL CHEMISTRY, 1984, 56 (12) :1258-&
[15]   CHROMATOGRAPHY WITH A TWO-DIMENSIONAL COLUMN [J].
GUIOCHON, G ;
GONNORD, MF ;
ZAKARIA, M ;
BEAVER, LA ;
SIOUFFI, AM .
CHROMATOGRAPHIA, 1983, 17 (03) :121-124
[16]   Parallel factor analysis (PARAFAC) of target analytes in GC x GC-TOFMS data: Automated selection of a model with an appropriate number of factors [J].
Hoggard, Jamin C. ;
Synovec, Robert E. .
ANALYTICAL CHEMISTRY, 2007, 79 (04) :1611-1619
[17]   Calculating optimal modulation periods to maximize the peak capacity in two-dimensional HPLC [J].
Horie, Kanta ;
Kimura, Hiroshi ;
Ikegami, Tohru ;
Iwatsuka, Akira ;
Saad, Nabil ;
Fiehn, Oliver ;
Tanaka, Nobuo .
ANALYTICAL CHEMISTRY, 2007, 79 (10) :3764-3770
[18]   Generation and Limitations of Peak Capacity in Online Two-Dimensional Liquid Chromatography [J].
Horvath, Krisztian ;
Fairchild, Jacob N. ;
Guiochon, Georges .
ANALYTICAL CHEMISTRY, 2009, 81 (10) :3879-3888
[19]   Optimization strategies for off-line two-dimensional liquid chromatography [J].
Horvath, Krisztian ;
Fairchild, Jacob ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (12) :2511-2518
[20]   Two-dimensional reversed-phase liquid chromatography using two monolithic silica C18 columns and different mobile phase modifiers in the two dimensions [J].
Ikegami, T ;
Hara, T ;
Kimura, H ;
Kobayashi, H ;
Hosoya, K ;
Cabrera, K ;
Tanaka, N .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1106 (1-2) :112-117