Macular Choroidal Thickness and Volume in Normal Subjects Measured by Swept-Source Optical Coherence Tomography

被引:295
|
作者
Hirata, Masaya
Tsujikawa, Akitaka [1 ]
Matsumoto, Akiko [2 ]
Hangai, Masanori
Ooto, Sotaro
Yamashiro, Kenji
Akiba, Masahiro [2 ]
Yoshimura, Nagahisa
机构
[1] Kyoto Univ, Grad Sch Med, Dept Ophthalmol & Visual Sci, Sakyo Ku, Kyoto 6068507, Japan
[2] Topcon Corp, Tokyo, Japan
基金
日本学术振兴会;
关键词
CENTRAL SEROUS CHORIORETINOPATHY; ULTRAHIGH-RESOLUTION; 1050; NM; ENHANCED VISUALIZATION; PATHOLOGICAL MYOPIA; POSTERIOR SEGMENT; HUMAN RETINA; AXIAL SCANS; HIGH-SPEED; OCT;
D O I
10.1167/iovs.11-7729
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To study the choroidal thickness in healthy subjects by swept-source optical coherence tomography (SS-OCT) at longer wavelength. METHODS. The macular area of 31 eyes (31 healthy volunteers) was studied with an SS-OCT prototype system, which uses a tunable laser as a light source operated at 100,000 Hz A scan repetition rate in the 1-mu m wavelength region. Three-dimensional volumetric measurement comprised of 512 x 128 A scans was acquired in 0.8 second. From a series of OCT images, a chroidal thickness map of the macular area was created by manual segmentation. To evaluate interoperator reproducibility, the choroidal thickness in each section from 10 subjects was determined independently by two observers. RESULTS. SS-OCT at the 1-mu m wavelength region allowed visualization of the fine structure of the choroid as well as that of the retina. Mean choroidal thickness and volume in the macula area were, respectively, 191.5 +/- 74.2 mu m and 5.411 +/- 2.097 mm(3). The mean choroidal thickness of the outer nasal area was significantly thinner than that of all other areas (P < 0.05). The measurements by the two independent observers were significantly identical; the intraclass correlation coefficient in mean choroidal thickness was between 0.945 and 0.980 in each area. The macular choroidal thickness was significantly correlated with axial length after adjustment for age (P < 0.001), and with age after adjustment for axial length (P < 0.001). CONCLUSIONS. SS-OCT system at 1 mu m provides macular choroidal thickness maps and allows one to evaluate the choroidal thickness more accurately. (Invest Ophthalmol Vis Sci. 2011;52:4971-4978) DOI:10.1167/iovs.11-7729
引用
收藏
页码:4971 / 4978
页数:8
相关论文
共 50 条
  • [1] Macular Choroidal Thickness in Normal Pediatric Population Measured by Swept-Source Optical Coherence Tomography
    Ruiz-Moreno, Jose M.
    Flores-Moreno, Inaki
    Lugo, Francisco
    Ruiz-Medrano, Jorge
    Montero, Javier A.
    Akiba, Masahiro
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (01) : 353 - 359
  • [2] Macular Choroidal Thickness and Volume in Healthy Pediatric Individuals Measured by Swept-Source Optical Coherence Tomography
    Nagasawa, Toshihiko
    Mitamura, Yoshinori
    Katome, Takashi
    Shinomiya, Kayo
    Naito, Takeshi
    Nagasato, Daisuke
    Shimizu, Yukiko
    Tabuchi, Hitoshi
    Kiuchi, Yoshiaki
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (10) : 7068 - 7074
  • [3] Macular choroidal thickness in normal Egyptians measured by swept source optical coherence tomography
    Magdy Moussa
    Dalia Sabry
    Wael Soliman
    BMC Ophthalmology, 16
  • [4] Macular choroidal thickness in normal Egyptians measured by swept source optical coherence tomography
    Moussa, Magdy
    Sabry, Dalia
    Soliman, Wael
    BMC OPHTHALMOLOGY, 2016, 16
  • [5] Macular Choroidal Thickness Profile in a Healthy Population Measured by Swept-Source Optical Coherence Tomography
    Ruiz-Medrano, Jorge
    Flores-Moreno, Ignacio
    Pena-Garcia, Pablo
    Montero, Javier A.
    Duker, Jay S.
    Ruiz-Moreno, Jose E. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (06) : 3532 - 3542
  • [6] Macular choroidal thickness profile in healthy population measured by swept-source optical coherence tomography
    Moreno, J. M. Ruiz
    Ruiz-Medrano, J.
    Flores-Moreno, I.
    Pena-Garcia, P.
    Montero, J. A.
    ACTA OPHTHALMOLOGICA, 2013, 91
  • [7] Macular Choroidal Thickness and Volume of Eyes With Reticular Pseudodrusen Using Swept-Source Optical Coherence Tomography
    Ueda-Arakawa, Naoko
    Ooto, Sotaro
    Ellabban, Abdallah A.
    Takahashi, Ayako
    Oishi, Akio
    Tamura, Hiroshi
    Yamashiro, Kenji
    Tsujikawa, Akitaka
    Yoshimura, Nagahisa
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (05) : 994 - 1004
  • [8] Measurement of the Choroidal Thickness in Normal Eyes with Swept-Source Optical Coherence Tomography
    Fagundes Fujihara, Fernanda Mari
    Farias, Lucas Brandolt
    Oliveira, Monica
    Lavinsky, Daniel
    Lavinsky, Fabio
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [9] Macular Choroidal Thickness and Volume in Eyes With Angioid Streaks Measured by Swept Source Optical Coherence Tomography
    Ellabban, Abdallah A.
    Tsujikawa, Akitaka
    Matsumoto, Akiko
    Ogino, Ken
    Hangai, Masanori
    Ooto, Sotaro
    Yamashiro, Kenji
    Akiba, Masahiro
    Yoshimura, Nagahisa
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 153 (06) : 1133 - 1143
  • [10] Choroidal thickness in the era of swept-source optical coherence tomography
    Agarwal, Aniruddha
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (02) : 256 - 257