Electrical Resistivity of Freezing Clay: Experimental Study and Theoretical Model

被引:19
作者
Ming, F. [1 ]
Li, D. Q. [1 ]
Chen, L. [1 ,2 ]
机构
[1] Chinese Acad Sci, State Key Lab Frozen Soil Engn, Northwest Inst Ecoenvironm & Resources, Lanzhou, Peoples R China
[2] Univ Chinese Acad Sci, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
freezing soil; unfrozen watercontent; temperature; pore size distribution; resistivity model; WATER-CONTENT; POROUS-MEDIA; ARCHIES LAW; CONDUCTIVITY MEASUREMENTS; UNFROZEN WATER; PARAMETERS; FROZEN; TRANSPORT; SOILS; IONS;
D O I
10.1029/2019JF005267
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
Electrical resistivity of soil has become one of the most important indicators of compactness and compressive resistance. In previous studies, the temperature of soil tested was always above 0 degrees C. However, due to the phase change of pore water, the resistivity of freezing soils is different from that of unfrozen soils. Therefore, it is necessary to clarify the influence of temperature on electrical resistivity. To achieve this goal, according to the bundle of the cylindrical capillary model, pores in soil were treated as conducting tubes, and two simple lognormal functions were introduced to describe the distribution of the conducting tubes. Based on the conductivity theory, a new model considering the temperature and the pore size distribution was presented. Results show that only a part of the conducting tubes can be treated as the effective conducting tubes, which are determined by the soil temperature. Furthermore, a small portion of the pores with the smaller size controlled the electrical resistivity of the freezing clay. In other words, the change in the electrical resistivity of freezing clay was caused mainly by the change of unfrozen water content through the decrease in temperature. Based on the experimental results conducted on clay from Northeast China, the validity of the presented model was verified. The comparison results indicate that there was a good agreement between the calculated results and the experimental results. To expand the scope of the model, more laboratory tests are suggested to conduct to verify the applicability of the model to other clays.
引用
收藏
页数:18
相关论文
共 75 条
[31]   RESISTIVITY-POROSITY-PARTICLE SHAPE RELATIONSHIPS FOR MARINE SANDS [J].
JACKSON, PD ;
TAYLORSMITH, D ;
STANFORD, PN .
GEOPHYSICS, 1978, 43 (06) :1250-1268
[32]   Visualization technique for liquefaction process in chamber experiments by using electrical resistivity monitoring [J].
Jinguuji, Motoharu ;
Toprak, Selcuk ;
Kunimatsu, Sunao .
SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2007, 27 (03) :191-199
[33]   Electrokinetic geosynthetics in hydraulic applications [J].
Jones, Colin J. F. P. ;
Larnont-Black, John ;
Glendinning, Stephanie .
GEOTEXTILES AND GEOMEMBRANES, 2011, 29 (04) :381-390
[34]   ELECTRICAL-RESISTIVITY MEASUREMENTS FOR EVALUATING COMPACTED-SOIL LINERS [J].
KALINSKI, RJ ;
KELLY, WE .
JOURNAL OF GEOTECHNICAL ENGINEERING-ASCE, 1994, 120 (02) :451-457
[35]  
Keller G.V., 1966, ELECT METHODS GEOPHY, V10
[36]  
Kim JH, 2011, GEOTECH TEST J, V34, P668
[37]   Comparison of dehydration in kaolin and illite using DC conductivity measurements [J].
Kubliha, Marian ;
Trnovcova, Viera ;
Ondruska, Jan ;
Stubna, Igor ;
Bosak, Ondrej ;
Kaljuvee, Tiit .
APPLIED CLAY SCIENCE, 2017, 149 :8-12
[38]   The effect of water saturation degree on the electrical properties of cement-based porous material [J].
Li, Qinghua ;
Xu, Shilang ;
Zeng, Qiang .
CEMENT & CONCRETE COMPOSITES, 2016, 70 :35-47
[39]   Characterization of dual-structure pore-size distribution of soil [J].
Li, X. ;
Zhang, L. M. .
CANADIAN GEOTECHNICAL JOURNAL, 2009, 46 (02) :129-141
[40]  
[刘国华 Liu Guohua], 2004, [岩土工程学报, Chinese Journal of Geotechnical Engineering], V26, P83