Highly selective and sensitive detection of cadmium ions by horseradish peroxidase enzyme inhibition using a colorimetric microplate reader and smartphone paper-based analytical device

被引:29
作者
Attaallah, Raouia [1 ]
Amine, Aziz [1 ]
机构
[1] Hassan II Univ Casablanca, Fac Sci & Tech, Lab Proc Engn & Environm, PA 146 Mohammedia, Casablanca 20800, Morocco
关键词
Colorimetric assay; Cadmium ion; Enzyme inhibition; Paper-based analytical device; RAPID DETECTION; WATER SAMPLES; METAL-IONS; SENSOR; BIOSENSOR; MICROEXTRACTION; PLATFORM; KIDNEY; CD;
D O I
10.1016/j.microc.2021.106940
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
With the knowledge of the extent of damage caused by cadmium ions (Cd2+), it becomes imperative to detect the presence of Cd2+ in drinking water with a rapid, efficient, and selective analytical method. Herein, a facile and novel colorimetric method for detecting cadmium ions, based on the irreversible inhibition of horseradish peroxidase (HRP) enzyme was established. Alternatively, a low-cost and affordable paper-based analytical device integrated with a smartphone platform was further designed to visualize, on-site and quantitative detection of Cd2+. The method developed for Cd2+ detection is of great interest to ensure a rapid diagnosis of water quality. Under the optimal conditions, the limit of detection of cadmium ions was 0.1 ppb, which is much lower than the permissible limit of WHO (5 ppb) for human exposure. Interference measurements showed that the method exhibited good selectivity. The proposed method was successfully applied as a rapid screening for cadmium ions monitoring in drinking water.
引用
收藏
页数:8
相关论文
共 67 条
[1]   Combined Kinetin and Spermidine Treatments Ameliorate Growth and Photosynthetic Inhibition in Vigna angularis by Up-Regulating Antioxidant and Nitrogen Metabolism under Cadmium Stress [J].
Ahanger, Mohammad Abass ;
Aziz, Usman ;
Alsahli, Abdulaziz Abdullah ;
Alyemeni, Mohammed Nasser ;
Ahmad, Parvaiz .
BIOMOLECULES, 2020, 10 (01)
[2]   A colorimetric paper-based analytical device coupled with hollow fiber membrane liquid phase microextraction (HF-LPME) for highly sensitive detection of hexavalent chromium in water samples [J].
Alahmad, Waleed ;
Tungkijanansin, Nuttanee ;
Kaneta, Takashi ;
Varanusupakul, Pakorn .
TALANTA, 2018, 190 :78-84
[3]   Recent advances in biosensors based on enzyme inhibition [J].
Amine, A. ;
Arduini, F. ;
Moscone, D. ;
Palleschi, G. .
BIOSENSORS & BIOELECTRONICS, 2016, 76 :180-194
[4]   Analytical aspects of enzyme reversible inhibition [J].
Amine, Aziz ;
El Harrad, Loubna ;
Arduini, Fabiana ;
Moscone, Danila ;
Palleschi, Giuseppe .
TALANTA, 2014, 118 :368-374
[5]  
[Anonymous], 2016, J TROP LIFE SCI, DOI DOI 10.11594/jtls.06.02.01
[6]   Fast, sensitive and cost-effective detection of nerve agents in the gas phase using a portable instrument and an electrochemical biosensor [J].
Arduini, Fabiana ;
Amine, Aziz ;
Moscone, Danila ;
Ricci, Francesco ;
Palleschi, Giuseppe .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (5-6) :1049-1057
[7]  
Attaallah R., 2020, NANOBIOSENSORS BIOCL, DOI [10.1007/978-3-030-39246-8_5, DOI 10.1007/978-3-030-39246-8_5]
[8]   Amperometric inhibition biosensors based on horseradish peroxidase and gold sononanoparticles immobilized onto different electrodes for cyanide measurements [J].
Attar, Aisha ;
Cubillana-Aguilera, Laura ;
Naranjo-Rodriguez, Ignacio ;
Hidalgo-Hidalgo de Cisneros, Jose Luis ;
Maria Palacios-Santander, Jose ;
Amine, Aziz .
BIOELECTROCHEMISTRY, 2015, 101 :84-91
[9]  
BALLY RW, 1989, J CLIN CHEM CLIN BIO, V27, P791
[10]   Modified nanoporous carbon as a novel sorbent before solvent-based de-emulsification dispersive liquid-liquid microextraction for ultra-trace detection of cadmium by flame atomic absorption spectrophotometry [J].
Behbahani, Mohammad ;
Esrafili, Ali ;
Bagheri, Saman ;
Radfar, Sima ;
Bojdi, Majid Kalate ;
Bagheri, Akbar .
MEASUREMENT, 2014, 51 :174-181