Relationship of indoor and outdoor air pollutants in a naturally ventilated historical building envelope

被引:60
作者
Lopez-Aparicio, S. [1 ]
Smolik, J. [2 ]
Maskova, L. [2 ,3 ]
Souckova, M.
Grontoft, T. [1 ]
Ondrackova, L. [2 ]
Stankiewicz, J. [4 ]
机构
[1] Norwegian Inst Air Res, NO-2027 Kjeller, Norway
[2] Acad Sci Czech Republ, Inst Chem Proc Fundamentals, Lab Aerosol Chem & Phys, CR-16502 Prague 6, Czech Republic
[3] Charles Univ Prague, Fac Sci, Inst Environm Studies, Prague 12801 2, Czech Republic
[4] Natl Lib Czech Republ, Prague 11000 1, Czech Republic
关键词
Indoor/outdoor ratio; Natural ventilation; Ammonia; Library; Organic acids; VOLATILE ORGANIC-COMPOUNDS; NITROGEN-DIOXIDE; QUALITY; ACID; AMMONIA; HEALTH; OZONE; OFFICE; MUSEUM; PENETRATION;
D O I
10.1016/j.buildenv.2011.01.013
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concentrations of NO2, O-3, SO2, acetic and formic acids, HNO3 and NH3 were measured inside and outside a historical building, the Baroque Library Hall (BLH) in the National Library in Prague (Czech Republic). The naturally ventilated system of the building, the restriction of personnel access, reduced groups of visitors and absence of activities which could influence indoor pollutant concentrations are characteristics that make the Baroque Library Hall a suitable location to study the influence of outdoor environment on the indoor air quality. The relationship between indoor and outdoor (I/O) concentration was investigated to assess the infiltration of outdoor generated pollutants. Outdoor and indoor pollution sources were determined and, infiltration of ammonium nitrate and a shift of the equilibrium to the gas phase were the reason for the high concentration of ammonia measured inside the BLH. A significant seasonal variation was observed and interpreted as a consequence of different infiltration regime associated with indoor-outdoor temperature differences, which in addition drives dilution processes of indoor generated pollutants. Based on the indoor air quality assessment performed in the BLH with regard to human and material exposure, there is reason for concern about material preservation and in particular paper at the BLH. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1460 / 1468
页数:9
相关论文
共 67 条
[1]  
*ACGIH, 2004, AM C GOV IND HYG TLV
[2]   INDOOR ORGANIC AND INORGANIC POLLUTANTS - IN-SITU FORMATION AND DRY DEPOSITION IN SOUTHEASTERN BRAZIL [J].
ALLEN, AG ;
MIGUEL, AH .
ATMOSPHERIC ENVIRONMENT, 1995, 29 (23) :3519-3526
[3]  
Andelova L, 2010, E PRESERV SCI, V7, P141
[4]  
[Anonymous], 2001, HDB FUNDAMENTALS
[5]  
[Anonymous], 2003, 117992003 ISO
[6]  
Atlas of the Prague environment, 2008, ATLAS PRAGUE ENV
[7]  
*ATSDR, 2004, TOX FAQ SHEET AMM
[8]   The health effects of nonindustrial indoor air pollution [J].
Bernstein, Jonathan A. ;
Alexis, Neil ;
Bacchus, Hyacinth ;
Bernstein, I. Leonard ;
Fritz, Pat ;
Horner, Elliot ;
Li, Ning ;
Mason, Stephany ;
Nel, Andre ;
Oullette, John ;
Reijula, Kari ;
Reponen, Tina ;
Seltzer, James ;
Smith, Alisa ;
Tarlo, Susan M. .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2008, 121 (03) :585-591
[9]   Relationship between outdoor and indoor air quality in eight French schools [J].
Blondeau, P ;
Iordache, V ;
Poupard, O ;
Genin, D ;
Allard, F .
INDOOR AIR, 2005, 15 (01) :2-12
[10]   INDOOR AND OUTDOOR CONCENTRATIONS OF INORGANIC ACIDIC AEROSOLS AND GASES [J].
BRAUER, M ;
KOUTRAKIS, P ;
KEELER, GJ ;
SPENGLER, JD .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1991, 41 (02) :171-181