Methodology for the design of diagnostic windows for Tore Supra

被引:5
作者
Missirlian, M [1 ]
Lipa, M [1 ]
Portafaix, C [1 ]
Gil, C [1 ]
Rey, G [1 ]
机构
[1] CEN Cadarache, EURATOM Assoc, DSM, DRFC,SIPP, F-13108 St Paul Les Durance, France
关键词
window-ferrule assemblies; thermo-mechanical analysis; Tore Supra;
D O I
10.1016/S0920-3796(03)00375-2
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The next generation of fusion experiments will operate for much longer pulse lengths within a context of high power density, introducing several new requirements for diagnostics compared with existing experiments. In this context, the upgrade of Tore Supra (CIEL Project) foresees high power and high radiating plasma scenario during very long pulse operation. This long plasma operation imposes the improvement of diagnostic systems and the design of thermally resistant in-vessel components with reliable window assemblies. Hence, the specific requirements and the methodology adopted to design Tore Supra/CIEL (TS) high thermal loaded diagnostic windows are summarised in this paper. Thermal and mechanical analyses are reported for different window materials and assembling methods. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:911 / 917
页数:7
相关论文
共 2 条
[1]   Development and testing of diagnostic windows for Tore Supra/CIEL and ITER [J].
Lipa, M ;
Portafaix, C ;
Pluyette, E ;
Walker, C ;
Lochet, N .
FUSION ENGINEERING AND DESIGN, 2002, 61-62 :801-806
[2]  
WEIBULL W, 1951, J APPL MECH-T ASME, V18, P293