Thermoluminescent dosimeters (TLDs-100) calibration for dose verification in photon and proton radiation therapy

被引:8
|
作者
D'Avino, V. [1 ]
Caruso, M. [2 ]
Arrichiello, C. [3 ]
Ametrano, G. [3 ]
La Verde, G. [1 ,4 ,5 ]
Muto, P. [3 ]
Scifoni, E. [6 ]
Tommasino, F. [6 ,7 ]
Pugliese, M. [1 ,4 ]
机构
[1] Natl Inst Nucl Phys, Sect Naples, Naples, Italy
[2] Univ Naples Federico II, Dept Elect Engn & Informat Technol, Naples, Italy
[3] Fdn G Pascale, IRCCS, Radiotherapy Unit, Ist Nazl Tumori, Naples, Italy
[4] Univ Naples Federico II, Dept Phys E Pancini, Naples, Italy
[5] Univ Naples Federico II, Dept Pharm, Naples, Italy
[6] Ist Nazl Fis Nucl, Trento Inst Fdn Phys & Applicat, TIFPA INFN, Trento, Italy
[7] Univ Trento, Dept Phys, Via Sommar 14, Trento, Italy
来源
NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS | 2020年 / 43卷 / 06期
关键词
DEPENDENCE; TOXICITY; DAMAGE;
D O I
10.1393/ncc/i2020-20142-0
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Thermoluminescent dosimeters (TLDs) are practical, accurate, and precise tools for point dosimetry in medical physics applications. TLDs are nowadays extensively used to measure dose in conformal radiation therapy in order to guarantee the safety of the treatment. Several national and international organizations recommend checking the effective dose delivered to an individual patient by means of in vivo dosimetry. Modern radiotherapy techniques employing both photon and ion beams exhibit excellent target conformation throught high steep-dose gradients between tumour and adjacent organs and tissues. In this context, catching potential dose errors and uncertainties in treatment delivering is the first step to ensure the optimization of the treatment plan. This study shows the results of the characterization of TLDs-100 at two Italian facilities devoted to advanced radiation treatments with photon and proton therapy. The individual sensitivity factor was determined, and the calibration curves were carried out in the dose range 0-20 Gy. By the analysis of the dose response curves, the linear region was identified under the dose level of 10 Gy. Characterization of the TLDs-100 has enabled their use for in vivo dosimetry especially in the dose range corresponding to the linear region of the dose response curves.
引用
收藏
页数:11
相关论文
共 24 条
  • [1] Preliminary investigation of performance of thermoluminescent dosimeters for dose verification in brachytherapy
    D'Avino, V.
    Scarica, M.
    Ametrano, G.
    La Verde, G.
    Manti, L.
    Muto, P.
    Pugliese, M.
    Arrichiello, C.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2020, 43 (06):
  • [2] Proton versus photon radiation therapy: A clinical review
    Chen, Zhe
    Dominello, Michael M. M.
    Joiner, Michael C. C.
    Burmeister, Jay W. W.
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [3] Dose response and stability of water equivalent PRESAGE® dosimeters for synchrotron radiation therapy dosimetry
    Gagliardi, Frank M.
    Franich, Rick D.
    Geso, Moshi
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (23)
  • [4] Morbidity dynamics in proton-photon or photon radiation therapy for locally advanced prostate cancer
    Khmelevsky, Evgeny V.
    Kancheli, Irina N.
    Khoroshkov, Vladimir S.
    Kaprin, Andrey D.
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2018, 23 (01) : 21 - 27
  • [5] The Biological Basis for Enhanced Effects of Proton Radiation Therapy Relative to Photon Radiation Therapy for Head and Neck Squamous Cell Carcinoma
    Wang, Li
    Fossati, Piero
    Paganetti, Harald
    Ma, Li
    Gillison, Maura
    Myers, Jeffrey N.
    Hug, Eugen
    Frank, Steven J.
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2021, 8 (01) : 3 - 13
  • [6] Zinc-Doped Iron Oxide Nanoparticles as a Proton-Activatable Agent for Dose Range Verification in Proton Therapy
    Ibanez-Moragues, Marta
    Fernandez-Barahona, Irene
    Santacruz, Rocio
    Oteo, Marta
    Lujan-Rodriguez, Victor M.
    Munoz-Hernando, Maria
    Magro, Natalia
    Lagares, Juan I.
    Romero, Eduardo
    Espana, Samuel
    Espinosa-Rodriguez, Andrea
    Garcia-Diez, Miguel
    Martinez-Nouvilas, Victor
    Sanchez-Tembleque, Victor
    Udias, Jose Manuel
    Valladolid-Onecha, Victor
    Martin-Rey, Miguel a.
    Almeida-Cordon, Edilia I.
    Vinals i Onses, Silvia
    Perez, Jose Manuel
    Fraile, Luis Mario
    Herranz, Fernando
    Morcillo, Miguel Angel
    MOLECULES, 2023, 28 (19):
  • [7] Spatial Dose Patterns Associated With Radiation Pneumonitis in a Randomized Trial Comparing Intensity-Modulated Photon Therapy With Passive Scattering Proton Therapy for Locally Advanced Non-Small Cell Lung Cancer
    Palma, Giuseppe
    Monti, Serena
    Xu, Ting
    Scifoni, Emanuele
    Yang, Pei
    Hahn, Stephen M.
    Durante, Marco
    Mohan, Radhe
    Liao, Zhongxing
    Cella, Laura
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 104 (05): : 1124 - 1132
  • [8] Advanced radiation therapy technologies in the treatment of rectal and anal cancer: Intensity-modulated photon therapy and proton therapy
    Meyer, Jeffrey
    Czito, Brian
    Yin, Fang-Fang
    Willett, Christopher
    CLINICAL COLORECTAL CANCER, 2007, 6 (05) : 348 - 356
  • [9] Dose compensation based on biological effectiveness due to interruption time for photon radiation therapy
    Kawahara, Daisuke
    Nakano, Hisashi
    Saito, Akito
    Ozawa, Shuichi
    Nagata, Yasushi
    BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1111)
  • [10] Technical note: High-dose and ultra-high dose rate (UHDR) evaluation of Al2O3:C optically stimulated luminescent dosimeter nanoDots and powdered LiF:Mg,Ti thermoluminescent dosimeters for radiation therapy applications
    Liu, Kevin
    Velasquez, Brett
    Schuler, Emil
    MEDICAL PHYSICS, 2024, 51 (03) : 2311 - 2319