Parametric study of the particulate fouling characteristics of vortex generators in a heat exchanger

被引:22
|
作者
Han, Zhimin [1 ]
Xu, Zhiming [1 ]
Qu, Hongwei [1 ]
机构
[1] Northeast Elect Power Univ, Sch Energy & Power Engn, Jilin, Jilin, Peoples R China
基金
中国国家自然科学基金;
关键词
Vortex generators; Heat exchanger; Fouling characteristics; Numerical simulation; PARTICLE DEPOSITION; RECTANGULAR CHANNEL; TRANSFER ENHANCEMENT; TUBE; FLOW; MODEL; SIMULATION; PREDICTION; TURBULENCE; OIL;
D O I
10.1016/j.applthermaleng.2019.114735
中图分类号
O414.1 [热力学];
学科分类号
摘要
The geometric parameters and flow characteristics of vortex generators have attracted much attention in recent years. For this study, an improved Eulerian method was used to study the fouling characteristics of magnesium oxide nanoparticles in a heat exchanger channel with rectangular wing vortex generators. The fouling characteristics of the channel with and without vortex generators were studied using numerical simulations, with the inlet velocity, magnesium oxide concentration, inlet temperature, and water-bath temperature at 0.5 m/s, 400 mg/L, 298 K, and 318 K, respectively. The simulation results for the rectangular heat channel with and without vortex generators were verified experimentally. Finally, the effects of the vortex generators' height, length, and spacing on particulate fouling characteristics were evaluated. In comparing the rectangular channel's fouling characteristics with and without vortex generators, the fouling resistance decreases by 19% for the channel with rectangular vortex generators, and it has the significant advantage of fouling inhibition. Furthermore, the fouling resistance decreases with the increase in the height and length of vortex generators. Conversely, the fouling resistance increases with increased spacing between the vortex generators.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Effect of Structure on the Circular Vortex Generators in CaSO4 Fouling Characteristics and Comprehensive Heat Transfer Characteristics
    Han Z.
    Liu Z.
    Wang J.
    Zhang Y.
    Xu Z.
    Xu, Zhiming (xuzm@mail.nedu.edu.cn), 1600, Chinese Society for Electrical Engineering (37): : 2920 - 2926
  • [42] Heat transfer enhancement in the novel wavy shaped heat exchanger channel with cylindrical vortex generators
    Brodnianska, Zuzana
    Kotsmid, Stanislav
    APPLIED THERMAL ENGINEERING, 2023, 220
  • [43] Parametric study of particle distribution in tube bundle heat exchanger
    Qi, Guopeng
    Jiang, Feng
    POWDER TECHNOLOGY, 2015, 271 : 210 - 220
  • [44] Numerical study on a slit fin-and-tube heat exchanger with longitudinal vortex generators
    Li, Jiong
    Wang, Shuangfeng
    Chen, Jinfang
    Lei, Yong-Gang
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (9-10) : 1743 - 1751
  • [45] Numerical study on formation characteristics of particle-crystal mixed fouling in the heat exchanger tube
    Wang, Yanjin
    Peng, Xiao
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 157
  • [47] Three-dimensional numerical study on fin-and-oval-tube heat exchanger with longitudinal vortex generators
    Chu, P.
    He, Y. L.
    Lei, Y. G.
    Tian, L. T.
    Li, R.
    APPLIED THERMAL ENGINEERING, 2009, 29 (5-6) : 859 - 876
  • [48] CFD analysis of fin tube heat exchanger with a pair of delta winglet vortex generators
    Hwang, Seong Won
    Kim, Dong Hwan
    Min, June Kee
    Jeong, Ji Hwan
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2012, 26 (09) : 2949 - 2958
  • [49] Numerical investigation of a finned-tube heat exchanger with novel longitudinal vortex generators
    Wang, Wenjin
    Bao, Yang
    Wang, Youqing
    APPLIED THERMAL ENGINEERING, 2015, 86 : 27 - 34
  • [50] Numerical Study on Particulate Fouling Characteristics of Flue with a Particulate Fouling Model Considering Deposition and Removal Mechanisms
    Liu, Peng
    Liu, Wei
    Gong, Kexin
    Han, Chengjun
    Zhang, Hong
    Sui, Zhucheng
    Hu, Renguo
    ENERGIES, 2022, 15 (22)