Comparison of two methods to assess PAEE during six activities in children

被引:75
作者
Corder, Kirsten [1 ]
Brage, Soren [1 ]
Mattocks, Calum [2 ]
Ness, Andy [2 ]
Riddoch, Chris [2 ,3 ]
Wareham, Nicholas J. [1 ]
Ekelund, Ulf [1 ]
机构
[1] Addenbrookes Hosp, MRC, Epidemiol Unit, Inst Metab Sci, Cambridge CB20QQ, England
[2] Univ Bristol, Bristol, Avon, England
[3] Univ Bath, Bath BA2 7AY, Avon, England
基金
英国医学研究理事会;
关键词
physical activity; energy expenditure; accelerometry; heart rate; ALSPAC;
D O I
10.1249/mss.0b013e318150dff8
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
CORDER, K., S. BRAGE, C. MATTOCKS, A. NESS, C. RIDDOCH, N. J. WAREHAM, and U. EKELUND. Comparison of Two Methods to Assess PAEE during Six Activities in Children. Med. Sci. Sports Exerc., Vol. 39, No. 12, pp. 2180-2188, 2007. Purpose: The purpose of this study was to compare the accuracy of physical activity energy expenditure (PAEE)-prediction models using accelerometry alone (ACC) and accelerometry combined with heart rate monitoring (HR+ACC) to estimate PAEE during six common activities in children (lying, sitting, slow and brisk walking, hop-scotch, running). Three PAEE-prediction models derived using the current data, and five previously published prediction models were cross-validated to estimate PAEE in this sample. Methods: PAEE was assessed using ACC, HR+ACC, and indirect calorimetry during six activities in 145 children (12.4 +/- 0.2 yr). One ACC and two HR+ACC PAEE-prediction models were derived using linear regression on data from the current study. These three new models were cross-validated using a jackknife approach, and a modified Bland-Altman method was used to assess the validity of all eight models. Results: PAEE predictions using the one ACC and two HR+ACC models derived in the current study correlated strongly with measured values (RMSE = 97.3-118.0 J.min(-1).kg(-1)). All five previously published models agreed well overall (RMSE = 115.6-245.3 J.min(-1).kg(-1)), but systematic error was present for most of these, to a greater extent for ACC. Conclusions: ACC and HR+ACC can both be used to predict overall PAEE during these six activities in children; however, systematic error was present in all predictions. Although both ACC and HR+ACC provide accurate predictions of overall PAEE, according to the activities in this study, PAEE-prediction models using HR+ACC may be more accurate and widely applicable than those based on accelerometry alone.
引用
收藏
页码:2180 / 2188
页数:9
相关论文
共 31 条
[1]  
*AM COLL SPORTS ME, 1996, ACSMS GUID EX TEST P
[2]  
[Anonymous], 1996, Development exercise physiology
[3]  
[Anonymous], 2003, Measurement in Physical Education and Exercise Science, DOI DOI 10.1207/S15327841MPEE0702_
[4]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[5]   Validity of four motion sensors in measuring moderate intensity physical activity [J].
Bassett, DR ;
Ainsworth, BE ;
Swartz, AM ;
Strath, SJ ;
O'Brien, WL ;
King, GA .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) :S471-S480
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]   Reexamination of validity and reliability of the CSA monitor in walking and running [J].
Brage, S ;
Wedderkopp, N ;
Franks, PW ;
Andersen, LB ;
Froberg, K .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (08) :1447-1454
[8]   Reliability and validity of the combined heart rate and movement sensor Actiheart [J].
Brage, S ;
Brage, N ;
Franks, PW ;
Ekelund, U ;
Wareham, NJ .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2005, 59 (04) :561-570
[9]   Branched equation modeling of simultaneous accelerometry and heart rate monitoring improves estimate of directly measured physical activity energy expenditure [J].
Brage, S ;
Brage, N ;
Franks, PW ;
Ekelund, U ;
Wong, MY ;
Andersen, LB ;
Froberg, K ;
Wareham, NJ .
JOURNAL OF APPLIED PHYSIOLOGY, 2004, 96 (01) :343-351
[10]   Influence of step frequency on movement intensity predictions with the CSA accelerometer: A field validation study in children [J].
Brage, S ;
Wedderkopp, N ;
Andersen, LB ;
Froberg, K .
PEDIATRIC EXERCISE SCIENCE, 2003, 15 (03) :277-287