The corrosion/wear mechanisms of Ti-6Al-4V alloy for different scratching rates

被引:49
作者
Komotori, Jun
Hisamori, Noriyuki
Ohmori, Yosuke
机构
[1] Keio Univ, Dept Mech Engn, Kouhoku Ku, Kanagawa 2238522, Japan
[2] Sophia Univ, Dept Mech Engn, Chiyodaku Ku, Tokyo, Japan
[3] Keio Univ, Sch Integrated Engn, Kouhoku Ku, Kanagawa, Japan
关键词
titanium alloys; corrosion; wear; scratching rate; corrosion wear damaged mechanism;
D O I
10.1016/j.wear.2006.11.025
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Titanium and its alloys are currently in use as implant materials for orthopaedic surgery. These materials possess outstanding corrosion resistance due to a dense and passive oxide film on the surface. When these alloys are implanted in a living body, removal of surface material takes place because of mechanical wear and corrosion. Simultaneous chemical and mechanical effects also limit long-term use of such materials. The aim of the present study is to clarify the damage accumulation mechanism of Ti-6Al-4V alloys under the simultaneous reaction of corrosion and wear. For this purpose, we developed a new tribocorrosion system and then evaluated corrosion wear characteristics of the alloys with special attention focused on the effects of scratching rate on repassivation behavior. Two types of corrosion wear tests were carried out: one was the free corrosion potential measurement and the other was the potentiostatic polarization test both with simultaneous application of wear damage. In corrosion wear environment, a transition of wear type from abrasive to adhesive was observed with increase of the scratching rates. Higher scratching rate prevented regeneration of passive films on worn surfaces, resulting in generation of relatively large corrosion pits and a change in the wear mechanism. These results suggested that the scratching rate was an important factor affecting the damage accumulation process. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:412 / 418
页数:7
相关论文
共 37 条
[1]   METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS [J].
AGINS, HJ ;
ALCOCK, NW ;
BANSAL, M ;
SALVATI, EA ;
WILSON, PD ;
PELLICCI, PM ;
BULLOUGH, PG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :347-356
[2]   Influence of surface self-modification in Ringer's solution on the passive behavior of titanium [J].
Alkhateeb, E ;
Virtanen, S .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2005, 75A (04) :934-940
[3]   Electrochemical effects on the fretting corrosion behaviour of Ti6Al4V in 0.9% sodium chloride solution [J].
Barril, S ;
Mischler, S ;
Landolt, D .
WEAR, 2005, 259 (1-6) :282-291
[4]   Influence of fretting regimes on the tribocorrosion behaviour of Ti6Al4V in 0.9wt.% sodium chloride solution [J].
Barril, S ;
Mischler, S ;
Landolt, D .
WEAR, 2004, 256 (9-10) :963-972
[5]   A tribo-electrochemical apparatus for in vitro investigation of fretting-corrosion of metallic implant materials [J].
Barril, S ;
Debaud, N ;
Mischler, S ;
Landolt, D .
WEAR, 2002, 252 (9-10) :744-754
[6]   EXPERIMENTAL LONG-TERM STUDY OF TITANIUM IONS ELUTED FROM PURE TITANIUM MINIPLATES [J].
BESSHO, K ;
FUJIMURA, K ;
IIZUKA, T .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (07) :901-904
[7]  
Bianco PD, 1996, J BIOMED MATER RES, V31, P227
[8]   Titanium serum and urine levels in rabbits with a titanium implant in the absence of wear [J].
Bianco, PD ;
Ducheyne, P ;
Cuckler, JM .
BIOMATERIALS, 1996, 17 (20) :1937-1942
[9]   Systemic titanium levels in rabbits with a titanium implant in the absence of wear [J].
Bianco, PD ;
Ducheyne, P ;
Cuckler, JM .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1997, 8 (09) :525-529
[10]   The effect of temperature on the nucleation of corrosion pits on titanium in Ringer's physiological solution [J].