Laser annealing for high-Q MEMS resonators

被引:15
|
作者
Aubin, KL [1 ]
Zalalutdinov, M [1 ]
Reichenbach, RB [1 ]
Houston, B [1 ]
Zehnder, AT [1 ]
Parpia, JM [1 ]
Craighead, HG [1 ]
机构
[1] Cornell Univ, Dept Appl & Engn Phys, Ithaca, NY 14853 USA
关键词
MEMS integration; resonator; quality factor; surface losses; laser annealing;
D O I
10.1117/12.499109
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
High frequency and high quality factor, Q, (defined as a half-width of the resonant peak) are the key factors that enable applications of microelectromechanical (MEMS) oscillators for supersensitive force detection or as elements for radio frequency signal processing. By shrinking the dimensions of MEMS resonators to the sub-micron range one increases the resonant frequency of the devices. Shrinking the devices, however, also increases the surface-to-volume ratio leading to a significant degradation of the quality factor (to below 5,000) due to the increased contribution of surface-related losses(11). We demonstrate that local annealing performed by focused low-power laser beams can improve the quality factor of MEMS resonators by more than an order of magnitude, which we attribute to the alteration of the surface state. Quality factors over 100,000 were achieved after laser annealing 3.1 MHz disc-type oscillators (radius R=10 micrometers, thickness h=0.25 micrometer) compared with a Q=6,000 for the as-fabricated device. The mushroom-type design of our resonator (a single-crystal silicon disc supported by a thin silicon dioxide pillar at the center) provides low heat loss. The combined power of a red HeNe laser (P-red=4mW) and a blue Ar+ ion laser (P-blue =5mW) focused on the periphery of the mushroom provides enough energy for surface modification. The post-treatment quality factor, exceeding 100,000 for MHz-range resonators, boosts the performance of MEMS to be comparable to that of lower frequency single-crystal quartz devices. The local nature of laser annealing, safe for surrounding electronics, is a crucial element for integration of MEMS resonators into an integrated circuit environment.
引用
收藏
页码:531 / 535
页数:5
相关论文
共 50 条
  • [31] Silica Glass for High-Q Mechanical Resonators
    Lunin, B. S.
    Lopatin, V. M.
    INORGANIC MATERIALS, 2020, 56 (03) : 292 - 296
  • [32] High-Q suspended optical resonators in 3C-SiC obtained by thermal annealing
    Powell, Keith
    Shams-Ansari, Amirhassan
    Desai, Smit
    Austin, Mitchell
    Deng, Jiangdong
    Sinclair, Neil
    Loncar, Marko
    Yi, Xiaoke
    2020 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2020,
  • [33] High-Q MEMS for wireless integrated circuits
    Lubecke, VM
    Barber, BP
    Fetter, LA
    TELSIKS 2001, VOL 1 & 2, PROCEEDINGS, 2001, : 203 - 209
  • [34] Power Handling Capability of High-Q Evanescent-mode RF MEMS Resonators with Flexible Diaphragm
    Liu, Xiaoguang
    Katehi, Linda P. B.
    Chappell, William J.
    Peroulis, Dimitrios
    APMC: 2009 ASIA PACIFIC MICROWAVE CONFERENCE, VOLS 1-5, 2009, : 194 - +
  • [35] Application of Pulsed Digital Oscillators in 'reverse mode' to eliminate undesired vibrations in high-Q MEMS resonators
    Dominguez, Manuel
    Pons, Joan
    Ricart, Jordi
    2007 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-11, 2007, : 925 - 928
  • [36] A CENTRALLY-ANCHORED HIGH-Q TUNABLE PIEZOELECTRIC MEMS RESONATORS FOR WIDE TEMPERATURE RANGE RTC
    Long, Yaoyao
    Liu, Zhenming
    Wehner, Charlotte
    Ayazi, Farrokh
    2023 IEEE INTERNATIONAL SYMPOSIUM ON INERTIAL SENSORS AND SYSTEMS, INERTIAL, 2023,
  • [37] Permanent Tuning of high-Q Silicon Microring Resonators by Fs Laser Surface Modification
    Bachman, D.
    Chen, Z.
    Fedosejevs, R.
    Tsui, Y. Y.
    Van, V.
    2013 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2013,
  • [38] High-Q Supercavity Modes in Subwavelength Dielectric Resonators
    Rybin, Mikhail V.
    Koshelev, Kirill L.
    Sadrieva, Zarina F.
    Samusev, Kirill B.
    Bogdanov, Andrey A.
    Limonov, Mikhail F.
    Kivshar, Yuri S.
    PHYSICAL REVIEW LETTERS, 2017, 119 (24)
  • [39] DECAY TIME MEASUREMENT FOR HIGH-Q ULTRASONIC RESONATORS
    EGGERS, F
    RICHMANN, KH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1976, 47 (03): : 378 - 379
  • [40] HIGH-Q ULTRASONIC LIQUID RESONATORS WITH CONCAVE TRANSDUCERS
    EGGERS, F
    FUNCK, T
    RICHMANN, KH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1976, 47 (03): : 361 - 367