Contact X-ray microscopy using Asterix

被引:2
|
作者
Conti, A
Batani, D
Botto, C
Masini, A
Bernardinello, A
Bortolotto, F
Moret, M
Poletti, G
Piccoli, S
Cotelli, F
Donin, CLL
Stead, A
Marranca, A
Eidmann, K
Flora, F
Palladino, L
Reale, L
机构
来源
APPLICATIONS OF X RAYS GENERATED FROM LASERS AND OTHER BRIGHT SOURCES | 1997年 / 3157卷
关键词
X-ray microscopy; laser produced plasmas; X-ray spectrometry; plasma diagnostics; photoresist; bioimaging;
D O I
10.1117/12.279419
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The use of a high energy laser source for Soft X-ray Contact Microscopy is discussed. Several different targets were used and their emission spectra compared. The X-ray emission, inside and outside the Water Window, was characterized in detail by means of many diagnostics, including pin hole and streak cameras. Up to 12 samples holders per shot were exposed thanks to the large X-ray flux and the geometry of the interaction chamber. Images of several biological samples were obtained, including Chlamydomonas and Crethidia green algae, fish and boar sperms and Saccharomyces Cerevisiae yeast cells. A 50 nm resolution was reached on the images of boar sperm. Original information concerning the density of inner structures of Crethidia green algae were obtained.
引用
收藏
页码:218 / 230
页数:13
相关论文
共 50 条
  • [1] X-ray microscopy of living multicellular organisms with the Prague Asterix Iodine Laser System
    Desai, T
    Batani, D
    Bernardinello, A
    Poletti, G
    Orsini, F
    Ullschmied, J
    Juha, L
    Skala, J
    Kralikova, B
    Krousky, E
    Pfeifer, M
    Kadlec, C
    Mocek, T
    Präg, A
    Renner, O
    Cotelli, F
    Lamia, CL
    Zullini, A
    LASER AND PARTICLE BEAMS, 2003, 21 (04) : 511 - 516
  • [2] Optimization of a laser-plasma x-ray source for contact x-ray microscopy
    Kondo, H., 1600, American Inst of Physics, Woodbury, NY, United States (75):
  • [3] X-ray microscopy
    Rokhlin, SI
    Kim, JY
    Zoofan, B
    TESTING, RELIABILITY, AND APPLICATION OF MICRO- AND NANO-MATERIAL SYSTEMS, 2003, 5045 : 132 - 146
  • [4] Study of x-ray microscopy using ultraviolet and x-ray double-resonance absorption
    Iketaki, Y
    Watanabe, T
    OPTICAL ENGINEERING, 1996, 35 (08) : 2418 - 2422
  • [5] Ultrastructure of human sperm using X-ray microscopy
    Abraham-Peskir, J
    Chantler, E
    McCann, C
    Medenwaldt, R
    Ernst, E
    MEDICAL SCIENCE RESEARCH, 1998, 26 (10): : 663 - 667
  • [6] The Measurement of MTFs in X-ray Microscopy Using Diffractograms
    Morrison, G. R.
    Charalambous, P. S.
    Gianoncelli, A.
    Kaulich, B.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 273 - 276
  • [7] X-ray microscopy using FELs: possibilities and challenges
    Jacobsen, C
    BIOMEDICAL APPLICATIONS OF FREE-ELECTRON LASERS, 2000, 3925 : 16 - 25
  • [8] X-ray omni microscopy
    Paganin, D
    Gureyev, TE
    Mayo, SC
    Stevenson, AW
    Nesterets, YI
    Wilkins, SW
    JOURNAL OF MICROSCOPY-OXFORD, 2004, 214 : 315 - 327
  • [9] A soft X-ray beamline for transmission X-ray microscopy at ALBA
    Pereiro, E.
    Nicolas, J.
    Ferrer, S.
    Howells, M. R.
    JOURNAL OF SYNCHROTRON RADIATION, 2009, 16 : 505 - 512
  • [10] Glass Monocapillary X-ray Optics And Their Applications In X-ray Microscopy
    Zeng, X.
    Feser, M.
    Huang, E.
    Lyon, A.
    Yun, W.
    X-RAY OPTICS AND MICROANALYSIS, PROCEEDINGS, 2010, 1221 : 41 - 47