Five-year follow-up of primary Optetrak Posterior Stabilized total knee arthroplasties in osteoarthritis

被引:14
作者
Robinson, RP
机构
[1] Virginia Mason Med Ctr, Sect Orthopaed, Dept Surg, Seattle, WA 98101 USA
[2] Univ Washington, Seattle, WA 98195 USA
关键词
total knee arthroplasty; optetrak; obesity;
D O I
10.1016/j.arth.2005.04.028
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A series of 66 primary Optetrak Posterior Stabilized total knees with modular tibial components were followed prospectively for a minimum of 5 years in patients with osteoarthritis. Fifty-one percent of the patients were obese based on body mass index greater than 30. There was a statistically significant negative correlation between body mass index and both Hospital for Special Surgery and Knee Society scores. Despite reduced ratings due to obesity, 90% of the patients were rated good or excellent. Patellofemoral design changes nearly eliminated patellofemoral crepitation and soft tissue entrapment. Design changes did not compromise implant survival. Predicted implant survival at 93 months using reoperation for any reason as an end point was 97%.
引用
收藏
页码:927 / 931
页数:5
相关论文
共 50 条
[31]   The EUROP total knee prosthesis: A ten-year follow-up study of a posterior cruciate-retaining design [J].
Mouttet, A. ;
Louis, M. -L. ;
Sourdet, V. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2011, 97 (06) :639-647
[32]   Five-year results of the Innex total knee arthroplasty system [J].
Urs K. Munzinger ;
Nicola A. Maffiuletti ;
Thomas Guggi ;
Mario Bizzini ;
Stefan Preiss ;
Tomas Drobny .
International Orthopaedics, 2010, 34 :1159-1165
[33]   10-Year Follow-Up of the NexGen CR Total Knee Prosthesis [J].
Hack, J. ;
Mai, S. ;
Siebert, W. .
ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2015, 153 (05) :508-515
[34]   Optimal patellar alignment with minimally invasive approaches in total knee arthroplasty after a minimum five year follow-up [J].
Ai-Bing Huang ;
Hai-Jun Wang ;
Jia-Kuo Yu ;
Bo Yang ;
Dong Ma ;
Ji-Ying Zhang .
International Orthopaedics, 2016, 40 :487-492
[35]   Kinematic analysis of kneeling in cruciate-retaining and posterior-stabilized total knee arthroplasties [J].
Hamai, Satoshi ;
Miura, Hiromasa ;
Higaki, Hidehiko ;
Matsuda, Shuichi ;
Shimoto, Takeshi ;
Sasaki, Kousuke ;
Yoshizumi, Masaaki ;
Okazaki, Ken ;
Tsukamoto, Nobuaki ;
Iwamoto, Yukihide .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2008, 26 (04) :435-442
[36]   Optimal patellar alignment with minimally invasive approaches in total knee arthroplasty after a minimum five year follow-up [J].
Huang, Ai-Bing ;
Wang, Hai-Jun ;
Yu, Jia-Kuo ;
Yang, Bo ;
Ma, Dong ;
Zhang, Ji-Ying .
INTERNATIONAL ORTHOPAEDICS, 2016, 40 (03) :487-492
[37]   Minimally invasive surgery (MIS) for total knee replacement; medium term results with minimum five year follow-up [J].
Unwin, Olivia ;
Hassaballa, Mohammed ;
Murray, James ;
Harries, William ;
Porteous, Andrew .
KNEE, 2017, 24 (02) :454-459
[38]   A Randomized Controlled Trial of Kinematically and Mechanically Aligned Total Knee Arthroplasties: Long-Term Follow-Up [J].
Dossett, H. Gene ;
Arthur, Jaymeson R. ;
Makovicka, Justin L. ;
Mara, Kristin C. ;
Bingham, Joshua S. ;
Clarke, Henry D. ;
Spangehl, Mark J. .
JOURNAL OF ARTHROPLASTY, 2023, 38 (06) :S209-S214
[39]   Comparison of Contact Kinematics in Posterior-Stabilized and Cruciate-Retaining Total Knee Arthroplasty at Long-Term Follow-Up [J].
Broberg, Jordan S. ;
Ndoja, Silvio ;
MacDonald, Steven J. ;
Lanting, Brent A. ;
Teeter, Matthew G. .
JOURNAL OF ARTHROPLASTY, 2020, 35 (01) :272-277
[40]   Mid-term clinical outcomes of a posterior stabilized total knee prosthesis for Japanese patients: A minimum follow-up of 5 years [J].
Nakagawa, Yusuke ;
Koga, Hideyuki ;
Nakamura, Tomomasa ;
Horie, Masafumi ;
Katagiri, Hiroki ;
Ozeki, Nobutake ;
Ohara, Toshiyuki ;
Sekiya, Ichiro ;
Muneta, Takeshi ;
Watanabe, Toshifumi .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2023, 28 (06) :1325-1330