Design and characterisation of a pulsed neutron interrogation facility

被引:13
作者
Favalli, A. [1 ]
Pedersen, B. [1 ]
机构
[1] Commiss European Communities, Joint Res Ctr, Inst Protect & Secur Citizen, I-21020 Ispra, Italy
关键词
D O I
10.1093/rpd/ncm016
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The Joint Research Centre recently obtained a license to operate a new experimental device intended for research in the field of nuclear safeguards. The research projects currently being planned for the new device includes mass determination of fissile materials in matrices and detection of contraband non-nuclear materials. The device incorporates a commercial pulsed neutron generator and a large graphite mantle surrounding the sample cavity. In this configuration, a relatively high thermal neutron flux with a long lifetime is achieved inside the sample cavity. By pulsing the neutron generator, a sample may be interrogated by a pure thermal neutron flux during repeated time periods. The paper reports on the design of the new device and the pulsed fast and thermal neutron source. The thermal neutron flux caused by the neutron generator and the graphite structure has been characterised by foil activation, fission chamber and 3 He proportional counter measurements.
引用
收藏
页码:74 / 77
页数:4
相关论文
共 6 条
[1]  
BREISMEISTER J, 1993, LA12625M LANL
[2]   Gamma ray spectroscopy features for detection of small explosives [J].
Gozani, T ;
Elsalim, M ;
Ingle, M ;
Phillips, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2) :482-485
[3]   Nondestructive fissile material assay by induced fission neutron correlation [J].
Hage, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 551 (2-3) :396-419
[4]  
HUNT JB, 1999, CERTIFICATE CLAIBRAT
[5]  
*INT AT EN AG, 1970, TECHN REP SER INT AT, V107
[6]   Measurement and Monte Carlo modelling of the JRC241 Am-Li(α,n) source spectrum [J].
Tagziria, H ;
Wiegel, B ;
Klein, H ;
Knauf, K ;
Wittstock, J ;
Zimbal, A .
RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) :129-134