摘要
We developed a new algorithm that fits optical coherence tomography (OCT) signals as a function of depth to a general theoretical OCT model which takes into account multiple scattering effects. With use of this algorithm, it was possible to extract both the scattering coefficient and anisotropy factor from a particular region of interest in an OCT image. The extraction algorithm was evaluated against measurements from an integrating sphere on a set of tissue phantoms and yielded valid results. Finally, a preliminary ex vivo OCT investigation on human aortic specimen indicated that the algorithm may contribute importantly to differentiation between normal and atherosclerotic arteries. We conclude that this algorithm may facilitate tissue characterization by OCT. (C) 2004 Optical Society of America.
引用
收藏
页码:249 / 259
页数:11
相关论文
共 24 条
  • [1] Bohren C., 1983, ABSORPTION SCATTERIN
  • [2] Evaluation of intracoronary stenting by intravascular optical coherence tomography
    Bouma, BE
    Tearney, GJ
    Yabushita, H
    Shishkov, M
    Kauffman, CR
    Gauthier, DD
    MacNeill, BD
    Houser, SL
    Aretz, HT
    Halpern, EF
    Jang, IK
    [J]. HEART, 2003, 89 (03) : 317 - 320
  • [3] Cheng C. C., 2000, PHYS REV A, V62, P1
  • [4] Noninvasive monitoring of glucose concentration with optical coherence tomography
    Esenaliev, RO
    Larin, KV
    Larina, IV
    Motamedi, M
    [J]. OPTICS LETTERS, 2001, 26 (13) : 992 - 994
  • [5] Clinical imaging of the high-risk or vulnerable atherosclerotic plaque
    Fayad, ZA
    Fuster, V
    [J]. CIRCULATION RESEARCH, 2001, 89 (04) : 305 - 316
  • [6] OPTICAL COHERENCE TOMOGRAPHY
    HUANG, D
    SWANSON, EA
    LIN, CP
    SCHUMAN, JS
    STINSON, WG
    CHANG, W
    HEE, MR
    FLOTTE, T
    GREGORY, K
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. SCIENCE, 1991, 254 (5035) : 1178 - 1181
  • [7] Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: Comparison with intravascular ultrasound
    Jang, IK
    Bouma, BE
    Kang, DH
    Park, SJ
    Park, SW
    Seung, KB
    Choi, KB
    Shishkov, M
    Schlendorf, K
    Pomerantsev, E
    Houser, SL
    Aretz, HT
    Tearney, GJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (04) : 604 - 609
  • [8] PHOTODYNAMIC THERAPY WITH ENDOGENOUS PROTOPORPHYRIN .9. BASIC PRINCIPLES AND PRESENT CLINICAL-EXPERIENCE
    KENNEDY, JC
    POTTIER, RH
    PROSS, DC
    [J]. JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 1990, 6 (1-2) : 143 - 148
  • [9] Assessing blood vessel abnormality via extracting scattering properties from OCT images
    Levitz, D
    Anderser, CB
    Frosz, MH
    Thrane, L
    Hansen, PR
    Jogensen, TM
    Anderson, PE
    [J]. OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE TECHNIQUES, 2003, 5140 : 12 - 19
  • [10] PROPAGATION OF A FINITE OPTICAL BEAM IN AN INHOMOGENEOUS MEDIUM
    LUTOMIRS.RF
    YURA, HT
    [J]. APPLIED OPTICS, 1971, 10 (07): : 1652 - &