Limit Carrying Capacity Calculation of Two-Way Slabs with Three Simply Supported Edges and One Clamped Edge under Fire

被引:1
|
作者
Zhu, Sanfan [1 ,2 ]
Dong, Yuli [1 ]
Ye, Sengui [1 ]
Zhang, Dashan [1 ]
Duan, Jintao [1 ]
机构
[1] Huaqiao Univ, Coll Civil Engn, Xiamen 361021, Peoples R China
[2] JianYan Test Grp Co Ltd, Xiamen 361004, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 03期
基金
中国国家自然科学基金;
关键词
two-way slab; three simply supported edges and one clamped edge; full-scale test; fire performance; limit bearing capacity; plate balance method; energy method; REINFORCED-CONCRETE SLABS; MODELING MEMBRANE ACTION; COMPOSITE BUILDINGS; FLOOR SLABS; BEHAVIOR; INPLANE; AMBIENT;
D O I
10.3390/app12031561
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Fire-resistance experiments were conducted on two full-scale two-way reinforced concrete slabs with three simply supported edges and one clamped edge. This paper presents the design of the furnace, specimens and clamped-end device, the test plan, and the measuring contents and methods. The cracking and failure characteristics of the tested two-way reinforced concrete slabs were introduced. The temperature field distribution of the concrete and steel in the direction of the section thickness, out-of-plane deflections, in-plane deflections, and angle of the slab edges of the two-way concrete slab under fire conditions were analyzed. Cracks form on the slab surface, which is shaped similar to the bottom of a shallow bowl, with two transverse cracks in the mid-area of the medially clamped side and intensively annular diagonal cracks on the corner side. There were several main transverse cracks in the central area of the slab surface. The results indicate that there was a significant decrease in frequency under fire conditions. Relations between the frequency and the central vertical deflection of the two slabs were analyzed by the regression method. This research generates valuable test data that can be used to validate the numerical models developed by fellow researchers in the field of structural fire engineering. Based on the plate balance method and energy method, calculation formula of the limit carrying capacity calculation formula of reinforced concrete two-way slabs with four different boundaries under fire are given, which are simply supported on three sides and clamped on one side. The influence of membrane effect under large deflection is considered in the formula, and the calculated results are in good agreement with the experimental results.
引用
收藏
页数:28
相关论文
共 12 条
  • [1] Limit Load Carrying Capacity of Two-Way Slabs with Two Edges Clamped and Two Edges Simply Supported in Fire
    Dong, Yu-li
    Zhu, Chong-ji
    JOURNAL OF STRUCTURAL ENGINEERING, 2011, 137 (10) : 1182 - 1192
  • [2] An energy method for calculation the load-carrying capacity of two-way slabs with two edges simply supported and two edges clamped in fire
    Zhu C.-J.
    Dong Y.-L.
    Zhu, Chong-Ji (zhuchongji@163.com), 2018, Tsinghua University (35): : 67 - 78and99
  • [3] Numerical analysis of simply supported two-way reinforced concrete slabs under fire
    Wang, Wenjun
    Jiang, Binhui
    Ding, Fa-xing
    Yu, Zhiwu
    COMPUTERS AND CONCRETE, 2023, 31 (06) : 469 - 484
  • [4] New analytical method for determining the load-carrying capacity of two-way simply supported concrete slabs
    Wang, Yong
    Zhang, Yajun
    Huang, Zhaohui
    Bisby, Luke A.
    ADVANCES IN STRUCTURAL ENGINEERING, 2018, 21 (11) : 1733 - 1748
  • [5] Calculation of ultimate bearing capacity of four kinds of two-way slabs with different boundaries under fire
    Zhu S.-F.
    Dong Y.-L.
    Zhang D.-S.
    Duan J.-T.
    Gongcheng Lixue/Engineering Mechanics, 2022, 39 (03): : 104 - 114
  • [6] Behaviour of full-scale two-way simply supported concrete slabs in fire
    Zhang, Da-shan
    Dong, Yu-li
    Fang, Yuan-yuan
    MAGAZINE OF CONCRETE RESEARCH, 2014, 66 (16) : 836 - 844
  • [7] Fire Test on Two-way Simply Supported Concrete Slab
    Yang, Zhinian
    Dong, Yuli
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING II, PTS 1-4, 2013, 405-408 : 2380 - +
  • [8] New Failure Criterion to Determine the Load Carrying Capacity of Two-Way Reinforced Concrete Slabs
    Wang, Yong
    Dong, Yu-Li
    Yuan, Guang-Lin
    Zou, Chao-Ying
    ADVANCES IN STRUCTURAL ENGINEERING, 2015, 18 (02) : 221 - 235
  • [9] Numerical analysis of simply supported one-way reinforced concrete slabs under fire condition
    Ding, Fa-xing
    Wang, Wenjun
    Jiang, Binhui
    Wang, Liping
    Liu, Xuemei
    COMPUTERS AND CONCRETE, 2021, 27 (04) : 355 - 367
  • [10] Edge-clamped two-way slabs containing low-ductility steel
    Sakka, Zafer
    Gilbert, R. Ian
    STRUCTURAL ENGINEERING AND MECHANICS, 2021, 78 (06) : 731 - 737