BackgroundTo evaluate long-term results of eyes with glaucoma drainage device (GDD).MethodsWe retrospectively reviewed medical records of all patients who underwent GDD placement at our institution between 2001 and 2014. A total of 110 eyes of 90 patients were studied. Glaucoma outcome was assessed by postoperative intraocular pressure (IOP), number of medications, and need for further glaucoma surgery. Surgical procedures before and during the study period, and their complications were evaluated.ResultsThe mean follow-up was 78.344.0months. The mean preoperative intraocular pressure was 30.8 +/- 6.9mmHg with 3.5 +/- 1.1 glaucoma medications. At last postoperative follow-up, the mean IOP decreased to 14.3 +/- 5.4mmHg with 1.6 +/- 1.5 glaucoma medications. GDD implantation successfully controlled glaucoma in 86, 85, 81, 78, 79, 76 and 73% of eyes at 1, 2, 3, 4, 5, 7 and 10years, respectively. At last follow-up IOP was successfully controlled in 67% of eyes. Clinical complications occurred in 56.4% of eyes during the follow-up period.Conclusions p id=Par4 A glaucoma drainage device can successfully control intractable glaucoma even after a very long period of time.
引用
收藏
页数:7
相关论文
共 17 条
[11]   Utilization of various glaucoma surgeries and procedures in medicare beneficiaries from 1995 to 2004 [J].
Ramulu, Pradeep Y. ;
Corcoran, Kevin J. ;
Corcoran, Suzanne L. ;
Robin, Alan L. .
OPHTHALMOLOGY, 2007, 114 (12) :2265-2270
[12]   Retrospective Review of Pars Plana Versus Anterior Chamber Placement of Baerveldt Glaucoma Drainage Device [J].
Rososinski, Anthony ;
Wechsler, David ;
Grigg, John .
JOURNAL OF GLAUCOMA, 2015, 24 (02) :95-99
[13]   Glaucoma drainage implants: a critical comparison of types [J].
Schwartz, Kenneth S. ;
Lee, Richard K. ;
Gedde, Steven J. .
CURRENT OPINION IN OPHTHALMOLOGY, 2006, 17 (02) :181-189
[14]   Pars plana tube insertion of glaucoma drainage implants and penetrating keratoplasty in patients with coexisting glaucoma and corneal disease [J].
Sidoti, PA ;
Mosny, AY ;
Ritterband, DC ;
Seedor, JA .
OPHTHALMOLOGY, 2001, 108 (06) :1050-1058
[15]   Long-term outcomes of Ahmed glaucoma valve implantation in refractory glaucomas [J].
Souza, Carlos ;
Tran, Duc H. ;
Loman, Jane ;
Law, Simon K. ;
Coleman, Anne L. ;
Caprioli, Joseph .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (06) :893-900
[16]   The Ahmed shunt versus the Baerveldt shunt for refractory glaucoma II - Longer-term outcomes from a single surgeon [J].
Tsai, JC ;
Johnson, CC ;
Kammer, JA ;
Dietrich, MS .
OPHTHALMOLOGY, 2006, 113 (06) :913-917
[17]   Experience with the use of Baerveldt and Ahmed glaucoma drainage implants in an Asian population [J].
Wang, JC ;
See, JLS ;
Chew, PTK .
OPHTHALMOLOGY, 2004, 111 (07) :1383-1388