An alternative solution to improve sensitivity of resonant microcantilever chemical sensors:: comparison between using high-order modes and reducing dimensions

被引:95
作者
Lochon, F [1 ]
Dufour, I [1 ]
Rebière, D [1 ]
机构
[1] Univ Bordeaux 1, ENSEIRB, CNRS, UMR 5818, F-33405 Talence, France
关键词
microcantilever; sensitivity; high-order mode; quality factor;
D O I
10.1016/j.snb.2004.11.086
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
By measuring shifts in the resonant frequency of a silicon microcantilever coated with a sensitive layer, it is possible to obtain a competitive chemical microsensor. In fact, the sensitivity of such a microsensor is improved when used in high resonant frequency device. Usually, to increase the resonant frequency, smaller microcantilevers are used. The limitation on increasing the natural frequency by reducing the microstructure size is often due to the limitation of the deflection measurement principle. Furthermore, it could also be difficult to obtain reproducible sensitive coatings on very small surfaces. In order to achieve high sensitivities corresponding to high frequencies without decreasing the microstructure size, high-order flexural modes can be considered. In this paper, it is demonstrated that the theoretical performance of the resonant microcantilever chemical sensor is essentially due to the resonant frequency value and not due to the mode order. The advantages of increasing the resonant frequency by using high-order modes is also confirmed experimentally. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:979 / 985
页数:7
相关论文
共 12 条
[1]   A chemical sensor based on a microfabricated cantilever array with simultaneous resonance-frequency and bending readout [J].
Battiston, FM ;
Ramseyer, JP ;
Lang, HP ;
Baller, MK ;
Gerber, C ;
Gimzewski, JK ;
Meyer, E ;
Güntherodt, HJ .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 77 (1-2) :122-131
[2]   Selectivity of chemical sensors based on micro-cantilevers coated with thin polymer films [J].
Betts, TA ;
Tipple, CA ;
Sepaniak, MJ ;
Datskos, PG .
ANALYTICA CHIMICA ACTA, 2000, 422 (01) :89-99
[3]  
Blevin R. D., 1978, FORMULAS NATURAL FRE, P108
[4]   Detection of heavy metal ions using protein-functionalized microcantilever sensors [J].
Cherian, S ;
Gupta, RK ;
Mullin, BC ;
Thundat, T .
BIOSENSORS & BIOELECTRONICS, 2003, 19 (05) :411-416
[5]   Experimental validation of theoretical models for the frequency response of atomic force microscope cantilever beams immersed in fluids [J].
Chon, JWM ;
Mulvaney, P ;
Sader, JE .
JOURNAL OF APPLIED PHYSICS, 2000, 87 (08) :3978-3988
[6]  
Gaspar J, 2003, MATER RES SOC SYMP P, V762, P151
[7]   An analytical model for support loss in micromachined beam resonators with in-plane flexural vibrations [J].
Hao, ZL ;
Erbil, A ;
Ayazi, F .
SENSORS AND ACTUATORS A-PHYSICAL, 2003, 109 (1-2) :156-164
[8]  
JI HF, 2001, SENSOR ACTUAT B-CHEM, V72, P393
[9]   Complementary metal oxide semiconductor cantilever arrays on a single chip: Mass-sensitive detection of volatile organic compounds [J].
Lange, D ;
Hagleitner, C ;
Hierlemann, A ;
Brand, O ;
Baltes, H .
ANALYTICAL CHEMISTRY, 2002, 74 (13) :3084-3095
[10]  
*MEMS, MEMS NAN CLEAR