EVALUATION OF VGC ANALYZER BY COMPARISON WITH GOLD STANDARD ROC SOFTWARE AND ANALYSIS OF SIMULATED VISUAL GRADING DATA
被引:14
作者:
Hansson, Jonny
[1
,2
]
Mansson, Lars Gunnar
[2
,3
]
Bath, Magnus
[2
,3
]
机构:
[1] Hosp Halland, Dept Biomed Engn, SE-43281 Varberg, Sweden
[2] Univ Gothenburg, Inst Clin Sci, Dept Radiat Phys, Sahlgrenska Acad, SE-41345 Gothenburg, Sweden
[3] Sahlgrens Univ Hosp, Dept Med Phys & Biomed Engn, SE-41345 Gothenburg, Sweden
基金:
瑞典研究理事会;
关键词:
DORFMAN-BERBAUM-METZ;
IMAGE QUALITY;
STATISTICAL-ANALYSIS;
CHEST RADIOGRAPHY;
DOSE REDUCTION;
BINORMAL MODEL;
MULTIREADER;
ACCURACY;
READERS;
D O I:
10.1093/rpd/ncab066
中图分类号:
X [环境科学、安全科学];
学科分类号:
08 ;
0830 ;
摘要:
The purpose of the present work was to evaluate the use of resampling statistical methods for analysis of visual grading data-implemented in the software VGC Analyzer-by comparing the reanalyzed results from previously performed visual grading studies with the results calculated by gold standard receiver operating characteristic (ROC) methodology, Obuchowski-Rockette (OR)-Dorfman-Berbaum-Metz (DBM) multiple-readers and multiple-case (MRMC) and by analysis of simulated visual grading data where the true distribution was presumed to be known. The reanalysis was performed on two multiple-reader studies with non-paired data and paired data, respectively. The simulation study was performed by simulating a large number of visual grading characteristics (VGC) studies and by analyzing the statistical distribution of null hypothesis (H-0) rejection rate. The comparison with OR-DBM MRMC showed good agreement when analyzing non-paired data for both fixed-reader and random-reader settings for the calculated area under the curve values and the confidence intervals (CIs). For paired data analysis, VGC Analyzer showed significantly lower CIs compared with the ROC software. This effect was also illustrated by the simulation study, where the VGC Analyzer, in general, showed good accuracy for simulated studies with stable statistical basis. For simulated studies with unstable statistics, the accuracy in the H-0 rejection rate decreased. The present study has shown that resampling methodology can be used to accurately perform the statistical analysis of a VGC study, although the resampling technique used makes the method sensitive to small data sets.
引用
收藏
页码:378 / 390
页数:13
相关论文