EVALUATION OF VGC ANALYZER BY COMPARISON WITH GOLD STANDARD ROC SOFTWARE AND ANALYSIS OF SIMULATED VISUAL GRADING DATA

被引:14
作者
Hansson, Jonny [1 ,2 ]
Mansson, Lars Gunnar [2 ,3 ]
Bath, Magnus [2 ,3 ]
机构
[1] Hosp Halland, Dept Biomed Engn, SE-43281 Varberg, Sweden
[2] Univ Gothenburg, Inst Clin Sci, Dept Radiat Phys, Sahlgrenska Acad, SE-41345 Gothenburg, Sweden
[3] Sahlgrens Univ Hosp, Dept Med Phys & Biomed Engn, SE-41345 Gothenburg, Sweden
基金
瑞典研究理事会;
关键词
DORFMAN-BERBAUM-METZ; IMAGE QUALITY; STATISTICAL-ANALYSIS; CHEST RADIOGRAPHY; DOSE REDUCTION; BINORMAL MODEL; MULTIREADER; ACCURACY; READERS;
D O I
10.1093/rpd/ncab066
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The purpose of the present work was to evaluate the use of resampling statistical methods for analysis of visual grading data-implemented in the software VGC Analyzer-by comparing the reanalyzed results from previously performed visual grading studies with the results calculated by gold standard receiver operating characteristic (ROC) methodology, Obuchowski-Rockette (OR)-Dorfman-Berbaum-Metz (DBM) multiple-readers and multiple-case (MRMC) and by analysis of simulated visual grading data where the true distribution was presumed to be known. The reanalysis was performed on two multiple-reader studies with non-paired data and paired data, respectively. The simulation study was performed by simulating a large number of visual grading characteristics (VGC) studies and by analyzing the statistical distribution of null hypothesis (H-0) rejection rate. The comparison with OR-DBM MRMC showed good agreement when analyzing non-paired data for both fixed-reader and random-reader settings for the calculated area under the curve values and the confidence intervals (CIs). For paired data analysis, VGC Analyzer showed significantly lower CIs compared with the ROC software. This effect was also illustrated by the simulation study, where the VGC Analyzer, in general, showed good accuracy for simulated studies with stable statistical basis. For simulated studies with unstable statistics, the accuracy in the H-0 rejection rate decreased. The present study has shown that resampling methodology can be used to accurately perform the statistical analysis of a VGC study, although the resampling technique used makes the method sensitive to small data sets.
引用
收藏
页码:378 / 390
页数:13
相关论文
共 46 条
[1]   Evaluation of an Iterative model-based reconstruction of pediatric abdominal CT with regard to image quality and radiation dose [J].
Aurumskjold, Marie-Louise ;
Soderberg, Marcus ;
Stalhammar, Fredrik ;
von Steyern, Kristina Vult ;
Tingberg, Anders ;
Ydstrom, Kristina .
ACTA RADIOLOGICA, 2018, 59 (06) :740-747
[2]   Visual grading characteristics (VGC) analysis:: a non-parametric rank-invariant statistical method for image quality evaluation [J].
Bath, M. ;
Mansson, L. G. .
BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (951) :169-176
[3]   VGC ANALYZER: A SOFTWARE FOR STATISTICAL ANALYSIS OF FULLY CROSSED MULTIPLE-READER MULTIPLE-CASE VISUAL GRADING CHARACTERISTICS STUDIES [J].
Bath, Magnus ;
Hansson, Jonny .
RADIATION PROTECTION DOSIMETRY, 2016, 169 (1-4) :46-53
[4]   Quantitative image quality evaluation of pelvic computed tomography-based imaging systems: A novel concept in radiotherapy [J].
Behrens, Claus F. ;
Andreasen, Tatiana B. ;
Lindberg, Henriette ;
Buhl, Sune K. ;
Vestergaard, Anne ;
Elstrom, Ulrik V. ;
Sjostrom, David .
ACTA ONCOLOGICA, 2013, 52 (07) :1579-1582
[5]   Linear Mixed-Effects Models and the Analysis of Nonindependent Data: A Unified Framework to Analyze Categorical and Continuous Independent Variables that Vary Within-Subjects and/or Within-Items [J].
Brauer, Markus ;
Curtin, John J. .
PSYCHOLOGICAL METHODS, 2018, 23 (03) :389-411
[6]   Visual Grading Characteristics (VGC) Analysis of Diagnostic Image Quality for High Resolution 3 Tesla MRI Volumetry of the Olfactory Bulb [J].
Burmeister, Hartmut Peter ;
Baltzer, Pascal Andreas Thomas ;
Moeslein, Constanze ;
Bitter, Thomas ;
Gudziol, Hilmar ;
Dietzel, Matthias ;
Guntinas-Lichius, Orlando ;
Kaiser, Werner Alois .
ACADEMIC RADIOLOGY, 2011, 18 (05) :634-639
[7]   Clinical evaluation of a dual-side readout technique computed radiography system in chest radiography of premature neonates [J].
Carlander, A. ;
Hansson, J. ;
Soderberg, J. ;
Steneryd, K. ;
Bath, M. .
ACTA RADIOLOGICA, 2008, 49 (04) :468-474
[8]   The effect of radiation dose reduction on clinical image quality in chest radiography of premature neonates using a dual-side readout technique computed radiography system [J].
Carlander, Anna ;
Hansson, Jonny ;
Soderberg, Jonas ;
Steneryd, Karin ;
Bath, Magnus .
RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) :275-280
[9]   Prediction Accuracy of a Sample-size Estimation Method for ROC Studies [J].
Chakraborty, Dev P. .
ACADEMIC RADIOLOGY, 2010, 17 (05) :628-638
[10]   MULTIREADER, MULTICASE RECEIVER OPERATING CHARACTERISTIC METHODOLOGY - A BOOTSTRAP ANALYSIS [J].
DORFMAN, DD ;
BERBAUM, KS ;
LENTH, RV .
ACADEMIC RADIOLOGY, 1995, 2 (07) :626-633