Comparison of various shear connectors for improved structural performance in CFS concrete composite slabs

被引:11
作者
Dar, M. Adil [1 ]
Subramanian, N. [2 ]
Dar, A. R. [3 ]
Ghowsi, Ahmad Fayeq [1 ]
Sidiqui, Faizan [3 ]
Fayaz, Sana [3 ]
Mir, M. Shoaib [3 ]
机构
[1] Indian Inst Technol Delhi, Dept Civil Engn, New Delhi, India
[2] Consulting Engineer, Baltimore, MD USA
[3] Natl Inst Technol Srinagar, Dept Civil Engn, Srinagar, Jammu & Kashmir, India
关键词
Slabs; Composite member; Shear connectors; Strength; Ductility; Stiffness; Cracks; End slip; FORMED STEEL BEAMS; COLUMNS; BEHAVIOR;
D O I
10.1016/j.engstruct.2020.111008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Composite sections comprising of wisely selected materials has gained popularity in the construction industry, as it may result in utilizing the advantages of two different materials thus resulting in efficient sections, which will not only reduce the dead loads but also provide economical solutions. Cold-formed steel (CFS) concrete composites have been used extensively in building construction, as the inherent weakness of local buckling in the CFS sections under compressive loading is taken care of by the concrete, which has significant compressive strength. This study presents an experimental investigation performed on full-scale simply supported CFS concrete composite slabs under four-point monotonic loading, with an aim to evaluate the effectiveness of the different shear connectors being adopted. The shear connectors were so adopted that they could provide the least possible interaction (for representing the no-interaction condition), partial-interaction and full-interaction between the steel deck sheet and the concrete slab. The performance of the various shear connectors was assessed in terms of strength, stiffness and ductility ratio. Cracking as well as end slippage were also studied. The test results were compared with a conventional RC slab, in terms of structural performance as well as cost and strength-to-weight ratio. The flexural test strengths were compared with the design strength quantified using the Euro Code. The degree of shear interaction was also investigated. It was found that the CFS concrete composite slabs not only performed better structurally but economically as well, in addition to providing significant strength-to-weight ratio, when compared to a conventional RC slab.
引用
收藏
页数:15
相关论文
共 32 条
[1]   Comparative study on longitudinal shear resistance of light weight concrete composite slabs with profiled sheets [J].
Aarthi, K. ;
Jeyshankaran, E. ;
Aranganathan, N. .
ENGINEERING STRUCTURES, 2019, 200
[2]  
Abbas HS, 2015, GRADEVINAR, V67, P225
[3]   Bending and Shear Experimental Tests and Numerical Analysis of Composite Slabs Made Up of Lightweight Concrete [J].
Alvarez Rabanal, F. P. ;
Guerrero-Munoz, J. ;
Alonso-Martinez, M. ;
Martinez-Martinez, J. E. .
JOURNAL OF ENGINEERING, 2016, 2016
[4]  
[Anonymous], 1994, Eurocode-4
[5]   Push-out tests on three innovative shear connectors for composite cold-formed steel concrete beams [J].
Bamaga, S. O. ;
Tahir, M. M. ;
Tan, C. S. ;
Shek, P. N. ;
Aghlara, R. .
CONSTRUCTION AND BUILDING MATERIALS, 2019, 223 :288-298
[6]   Structural Behaviour of Cold-Formed Steel of Double C-Lipped Channel Sections Integrated with Concrete Slabs as Composite Beams [J].
Bamaga, S. O. ;
Tahir, M. M. ;
Ngian, S. P. ;
Mohamad, S. ;
Sulaiman, A. ;
Aghlara, R. .
LATIN AMERICAN JOURNAL OF SOLIDS AND STRUCTURES, 2019, 16 (05)
[7]   Axial compression behavior of laced cold-formed steel built-up columns with unstiffened angle sections [J].
Dar, M. Adil ;
Sahoo, Dipti Ranjan ;
Jain, Arvind K. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 162
[8]   Structural efficiency of various strengthening schemes for cold-formed steel beams: Effect of global imperfections [J].
Dar, M. Adil ;
Subramanian, N. ;
Dar, A. R. ;
Majid, Muheeb ;
Haseeb, Mohd ;
Tahoor, Mugees .
STEEL AND COMPOSITE STRUCTURES, 2019, 30 (04) :393-403
[9]   Behaviour of laced built-up cold-formed steel columns: Experimental investigation and numerical validation [J].
Dar, M. Adil ;
Sahoo, Dipti Ranjan ;
Pulikkal, Sunil ;
Jain, Arvind K. .
THIN-WALLED STRUCTURES, 2018, 132 :398-409
[10]  
Gholamhoseini Alireza, 2018, International Journal of Advanced Structural Engineering, V10, P85, DOI 10.1007/s40091-018-0183-3