Comparative Analysis between Conventional PI and Fuzzy Logic PI Controllers for Indoor Benzene Concentrations

被引:11
作者
Pitalua-Diaz, Nun [1 ]
Herrera-Lopez, Enrique J. [2 ]
Valencia-Palomo, Guillermo [3 ]
Gonzalez-Angeles, Alvaro [4 ]
Rodriguez-Carvajal, Ricardo A. [1 ]
Cazarez-Castro, Nohe R. [5 ]
机构
[1] Univ Sonora, Dept Ingn Ind, Col Ctr Hermosillo 83000, Sonora, Mexico
[2] Ctr Invest & Asistencia Tecnol & Diseno Estado Ja, Biotecnol Ind, Colinas Normal Guadalaja 44270, Jalisco, Mexico
[3] Inst Tecnol Hermosillo, Hermosillo 83170, Sonora, Mexico
[4] Univ Autonoma Baja California, Fac Ingn Campus Mexicali, Mexicali 21280, Baja California, Mexico
[5] Inst Tecnol Tijuana, Dept Ingn Elect & Elect, Tijuana 22414, Baja California, Mexico
关键词
benzene; PI controller; fuzzy logic PI controller; well-mixed room model; hazardous; indoor; AIR-QUALITY CONTROL; EXPOSURE;
D O I
10.3390/su7055398
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Exposure to hazardous concentrations of volatile organic compounds indoors in small workshops could affect the health of workers, resulting in respirative diseases, severe intoxication or even cancer. Controlling the concentration of volatile organic compounds is required to prevent harmful conditions for workers in indoor environments. In this document, PI and fuzzy PI controllers were used to reduce hazardous indoor air benzene concentrations in small workplaces. The workshop is represented by means of a well-mixed room model. From the knowledge obtained from the model, PI and fuzzy PI controllers were designed and their performances were compared. Both controllers were able to maintain the benzene concentration within secure levels for the workers. The fuzzy PI controller performed more efficiently than the PI controller. Both approaches could be expanded to control multiple extractor fans in order to reduce the air pollution in a shorter time. The results from the comparative analysis showed that implementing a fuzzy logic PI controller is promising for assuring indoor air quality in this kind of hazardous work environment.
引用
收藏
页码:5398 / 5412
页数:15
相关论文
共 36 条
[1]   PID control system analysis, design, and technology [J].
Ang, KH ;
Chong, G ;
Li, Y .
IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2005, 13 (04) :559-576
[2]  
ATSDR, 2007, TOX PROF BENZ
[3]   Current understandings and perspectives on non-cancer health effects of benzene: A global concern [J].
Bahadar, Haji ;
Mostafalou, Sara ;
Abdollahi, Mohammad .
TOXICOLOGY AND APPLIED PHARMACOLOGY, 2014, 276 (02) :83-94
[4]  
Brinkman D.W.B., 1990, VOLATILE SOLVENT EVA
[5]   Development of a dual-mode demand control ventilation strategy for indoor air quality control and energy saving [J].
Chao, CYH ;
Hu, JS .
BUILDING AND ENVIRONMENT, 2004, 39 (04) :385-397
[6]   Model Development and Validation of Personal Exposure to Volatile Organic Compound Concentrations [J].
Delgado-Saborit, Juana Mari ;
Aquilina, Noel J. ;
Meddings, Claire ;
Baker, Stephen ;
Harrison, Roy M. .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2009, 117 (10) :1571-1579
[7]  
Dongrui W., 2010, P IEEE INT C GRAN CO, P803
[8]   Evaluation of faults impacts on energy consumption and indoor air quality on an air handling unit [J].
Ginestet, S. ;
Marchio, D. ;
Morisot, O. .
ENERGY AND BUILDINGS, 2008, 40 (01) :51-57
[9]  
International Agency for Research on Cancer (IARC), SUMM EV
[10]   Cancer mortality among workers with benzene exposure [J].
Ireland, B ;
Collins, JJ ;
Buckley, CF ;
Riordan, SG .
EPIDEMIOLOGY, 1997, 8 (03) :318-320