Fabrication of reduced graphene oxide-bimetallic PdAu nanocomposites for the electrochemical determination of ascorbic acid, dopamine, uric acid and rutin

被引:77
作者
Zou, Cui'e [1 ]
Zhong, Jiatai [1 ]
Li, Shin [1 ]
Wang, Huiwen [2 ]
Wang, Jin [1 ]
Yan, Bo [1 ]
Du, Yukou [1 ,3 ]
机构
[1] Soochow Univ, Coll Chem Chem Engn & Mat Sci, Suzhou 215123, Peoples R China
[2] Yancheng Teachers Univ, Sch Chem & Environm Engn, Yancheng City 224002, Jiangsu, Peoples R China
[3] Tokyo Univ Sci Yamaguchi, Sanyoonoda, Yamaguchi 7560884, Japan
基金
中国国家自然科学基金;
关键词
PdAu bimetallic nanocomposite; Electrochemical determination; Ascorbic acid; Dopamine; Uric acid; Rutin; GLASSY-CARBON ELECTRODE; HYDROGEN-PEROXIDE; FACILE SYNTHESIS; VITAMIN-C; SENSOR; NANOPARTICLES; METAANALYSIS; NANOSPHERES; DISEASE;
D O I
10.1016/j.jelechem.2017.10.020
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, an easy and green method was employed to successfully develop PdAu/graphene (RGO) nano composites, and PdAu/RGO/GCE was applied for the electrochemically detection of ascorbic acid (AA), dopamine (DA), uric acid (UA) and rutin. The electrochemical methods, such as cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were used to evaluate the electrochemical performances toward AA, UA, DA and rutin on the PdAu/RGO/GCE. Good linearships were observed for all the four molecules in the ranges of 12.5-700 mu M, 1.25-73.75 mu M, 2.5-66.25 mu M and 0.025-5.625 mu M, with the detection limits of 12.5 mu M, 0.75 mu M, 2.5 mu M and 0.025 mu M, respectively. Finally, the modified electrode has fairly good performance during the employment of real sample analysis to determine the content of AA, DA, UA and rutin. These results all indicate that the RGO modified bimetallic nanomaterials are supposed to be a promising material in the electrochemical determination of small biological molecules.
引用
收藏
页码:110 / 119
页数:10
相关论文
共 43 条
[1]  
Arguello J., 2008, BIOSENSORS, V24, P632
[2]   Systematic review and meta-analysis of randomised controlled trials testing the effects of vitamin C supplementation on blood lipids [J].
Ashor, Ammar W. ;
Siervo, Mario ;
van der Velde, Femke ;
Willis, Naomi D. ;
Mathers, John C. .
CLINICAL NUTRITION, 2016, 35 (03) :626-637
[3]   Effect of vitamin C on endothelial function in health and disease: A systematic review and meta-analysis of randomised controlled trials [J].
Ashor, Ammar W. ;
Lara, Jose ;
Mathers, John C. ;
Siervo, Mario .
ATHEROSCLEROSIS, 2014, 235 (01) :9-20
[4]   Uric acid levels in subjects with bipolar disorder: A comparative meta-analysis [J].
Bartoli, Francesco ;
Crocamo, Cristina ;
Mazza, Mario Gennaro ;
Clerici, Massimo ;
Carra, Giuseppe .
JOURNAL OF PSYCHIATRIC RESEARCH, 2016, 81 :133-139
[5]   Electrochemical sensors and biosensors based on less aggregated graphene [J].
Bo, Xiangjie ;
Zhou, Ming ;
Guo, Liping .
BIOSENSORS & BIOELECTRONICS, 2017, 89 :167-186
[6]   Ultrasensitive and simultaneous detection of hydroquinone, catechol and resorcinol based on the electrochemical co-reduction prepared Au-Pd nanoflower/reduced graphene oxide nanocomposite [J].
Chen, Yuan ;
Liu, Xiaoying ;
Zhang, Si ;
Yang, Liuqing ;
Liu, Meiling ;
Zhang, Youyu ;
Yao, Shouzhuo .
ELECTROCHIMICA ACTA, 2017, 231 :677-685
[7]   A review on plant-based rutin extraction methods and its pharmacological activities [J].
Chua, Lee Suan .
JOURNAL OF ETHNOPHARMACOLOGY, 2013, 150 (03) :805-817
[8]   Electrochemical sensor for epinephrine based on a glassy carbon electrode modified with graphene/gold nanocomposites [J].
Cui, Fei ;
Zhang, Xiaoli .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 669 :35-41
[9]  
Du J., 2012, TALANTA, V99, P984
[10]   Simultaneous determination of uric acid and dopamine using a carbon fiber electrode modified by layer-by-layer assembly of graphene and gold nanoparticles [J].
Du, Jiao ;
Yue, Ruirui ;
Ren, Fangfang ;
Yao, Zhangquan ;
Jiang, Fengxing ;
Yang, Ping ;
Du, Yukou .
GOLD BULLETIN, 2013, 46 (03) :137-144