Subcostal real-time three-dimensional echocardiography of interatrial communications: reconstruction of an oval fossa defect, a superior sinus venosus defect with partially anomalous pulmonary venous drainage, an infero-posterior oval fossa defect, and a coronary sinus defect

被引:1
作者
Bilska, Karolina M. G. [1 ]
Kehrens, Claudia M. J. [1 ]
Riley, Gillian [1 ]
Anderson, Robert H. [2 ]
Marek, Jan [1 ]
机构
[1] Great Ormond St Hosp Sick Children, Dept Cardiol, London WC1N 3JH, England
[2] UCL, Inst Child Hlth, London WC1E 6BT, England
关键词
Atrial communications; real-time three-dimensional echocardiography; atrial septal defect; ATRIAL SEPTAL-DEFECT; EUSTACHIAN VALVE; IN-VITRO; CLOSURE;
D O I
10.1017/S1047951111001107
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Real-time three-dimensional echocardiography can surpass simple cross-sectional echocardiography in providing precise details of cardiac lesions. For the purpose of optimising treatment, we describe our findings with real-time three-dimensional echocardiography when interrogating different types of communications permitting interatrial shunting. A three-dimensional reconstruction of defects within the oval fossa enabled reliable identification of location, size, and integrity of surrounding rims. In the superior sinus venosus defect associated with partially anomalous pulmonary venous drainage, three-dimensional reconstruction helped to provide a better understanding of the relationship between the interatrial communication, the orifice of the superior caval vein, and the connections of the right upper pulmonary vein. In the defect opening infero-posteriorly within the oval fossa, three-dimensional reconstruction helped to avoid the risk of potentially inappropriate closure of the defect by suturing the hyperplastic Eustachian valve to the atrial wall, which could have diverted the inferior caval venous return into the left atrium, or obstructed the caval venous orifice. In the coronary sinus defect, three-dimensional echocardiography provided a 'face to face' view of the entire coronary sinus roof, showing a circular defect communicating with the cavity of the left atrium. Acquisition of the full-volume data sets took less than 2 minutes for the patients having defects within the oval fossa, and no more than 3 minutes for the patients with the sinus venosus and coronary sinus defects. Post-processing for the defects in the oval fossa took from 5 to 8 minutes, and from 12 to 16 minutes for the more complicated defects. Conclusion: Cross-sectional two-dimensional echocardiography can establish correct diagnosis in all types of atrial communications; however, real-time three-dimensional reconstruction provides additional value to the surgeon and interventionist for better understanding of spatial intracardiac morphology.
引用
收藏
页码:145 / 151
页数:7
相关论文
共 15 条
  • [1] Unroofed coronary sinus with persistent left superior vena cava assessed by 3D echocardiography
    Acar, Philippe
    Arran, Stepan
    Paranon, Soizic
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2008, 25 (06): : 666 - 667
  • [2] Acute inferior cardiac inflow obstruction resulting from inadvertent surgical closure of a prominent eustachian valve mistaken for an atrial septal defect
    Becker, A
    Buss, M
    Sebening, W
    Meisner, H
    Döhlemann, C
    [J]. PEDIATRIC CARDIOLOGY, 1999, 20 (02) : 155 - 157
  • [3] Beerman LB, 2002, PAEDIAT CARDIOLOGY, P902
  • [4] Real time three-dimensional transthoracic echocardiography for guiding Amplatzer septal occluder device deployment in patients with atrial septal defect
    Chen, Fong L.
    Hsiung, Ming C.
    Hsieh, Kai S.
    Li, Yi C.
    Chou, Ming C.
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2006, 23 (09): : 763 - 770
  • [5] Real time three-dimensional echocardiography in assessing ventricular septal defects: An echocardiographic-surgical correlative study
    Chen, Fong Lin
    Hsiung, Ming Chon
    Nanda, Navin
    Hsieh, Kai Sheng
    Chou, Ming Chih
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2006, 23 (07): : 562 - 568
  • [6] Transesophageal real-time three-dimensional echocardiography - Methods and initial in vitro and human in vivo studies
    Handke, Michael
    Heinrichs, Gudrun
    Moser, Urs
    Hirt, Felix
    Margadant, Felix
    Gattiker, Felix
    Bode, Christoph
    Geibel, Annette
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (10) : 2070 - 2076
  • [7] Morgan GJ, 2008, EUR J ECHOCARDIOGR
  • [8] CYANOSIS IN ATRIAL SEPTAL-DEFECT DUE TO PERSISTENT EUSTACHIAN VALVE
    MORISHITA, Y
    YAMASHITA, M
    YAMADA, K
    ARIKAWA, K
    TAIRA, A
    [J]. ANNALS OF THORACIC SURGERY, 1985, 40 (06) : 614 - 616
  • [9] Real-time subcostal 3-dimensional echocardiography for guided percutaneous atrial septal defect closure
    Roman, KS
    Nii, M
    Golding, F
    Benson, LN
    Smallhorn, JF
    [J]. CIRCULATION, 2004, 109 (24) : E320 - E321
  • [10] Laceration of atrial septum during balloon sizing of atrial septal defect
    Sivasankaran, S.
    Harikrishnan, S.
    Narayanan, Namboodiri
    Jaganmohan, Tharakan
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2007, 8 (02): : 89 - 90