Simultaneous quantification of methylated purines in DNA by isotope dilution LC-MS/MS coupled with automated solid-phase extraction

被引:23
|
作者
Hu, Chiung-Wen [2 ,3 ]
Chen, Chih-Ming [1 ]
Ho, Hsin Hui [1 ]
Chao, Mu-Rong [1 ]
机构
[1] Chung Shan Med Univ, Dept Occupat Safety & Hlth, Taichung 402, Taiwan
[2] Chung Shan Med Univ, Dept Publ Hlth, Taichung 402, Taiwan
[3] Chung Shan Med Univ Hosp, Dept Family & Community Med, Taichung 402, Taiwan
关键词
Online solid-phase extraction; LC-MS/MS; Methylated DNA; Methyl methanesulfonate; PERFORMANCE LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; LIVER DNA; ADDUCTS; O-6-METHYLGUANINE; 7-METHYLGUANINE; N7-METHYLGUANINE; QUANTITATION; ALKYLATION; EXPOSURE;
D O I
10.1007/s00216-011-5559-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Since methylation at the N-7 and O-6 positions of guanine and the N-3 position of adenine in DNA are the predominant reaction sites, N (7)-methylguanine (N (7)-MeG), O (6)-methylguanine (O (6)-MeG), and N (3)-methyladenine (N (3)-MeA) have been suggested as good biomarkers for assessing exposure to methylating agents. Here, we report the development of a sensitive and selective assay based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) to simultaneously measure N (7)-MeG, O (6)-MeG, and N (3)-MeA in DNA hydrolysates. With the use of isotope internal standards (N-15(5)-N (7)-MeG, d (3)-O (6)-MeG, and d (3)-N (3)-MeA) and online solid-phase extraction, DNA hydrolysates can be directly analyzed within 12 min without prior sample purification. The limits of detection were 0.02, 0.002, and 0.01 ng/mL on-column (6.1, 0.6, and 3.4 fmol) for N (7)-MeG, O (6)-MeG, and N (3)-MeA, respectively. Inter- and intraday imprecision (CV) were 3.6-9.6% and 2.7-13.6%, respectively. Mean recoveries were 96-109%. This method was then applied to quantitate the amounts of methylated purines in calf thymus DNA treated with methyl methanesulfonate (MMS). The levels of N (7)-MeG, O (6)-MeG, and N (3)-MeA in calf thymus DNA increase with MMS concentration and incubation time. The ratio of relative yields of N (7)-MeG, O (6)-MeG, and N (3)-MeA in MMS-treated DNA was found to be 1.00:0.0032:0.119, respectively. This LC-MS/MS assay provides the sensitivity and high throughput required to evaluate the extent of methylated lesions in DNA induced by methylating agents.
引用
收藏
页码:1199 / 1208
页数:10
相关论文
共 50 条
  • [1] Simultaneous quantification of methylated purines in DNA by isotope dilution LC-MS/MS coupled with automated solid-phase extraction
    Chiung-Wen Hu
    Chih-Ming Chen
    Hsin Hui Ho
    Mu-Rong Chao
    Analytical and Bioanalytical Chemistry, 2012, 402 : 1199 - 1208
  • [2] Determination of urinary malondialdehyde by isotope dilution LC-MS/MS with automated solid-phase extraction: A cautionary note on derivatization optimization
    Chen, Jian-Lian
    Huang, Yu-Jie
    Pan, Chih-Hong
    Hu, Chiung-Wen
    Chao, Mu-Rong
    FREE RADICAL BIOLOGY AND MEDICINE, 2011, 51 (09) : 1823 - 1829
  • [3] Quantitative determination of urinary N3-methyladenine by isotope-dilution LC-MS/MS with automated solid-phase extraction
    Hu, Chiung-Wen
    Lin, Bo-Huei
    Chao, Mu-Rong
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2011, 304 (2-3) : 68 - 73
  • [4] Extraction and quantification of phytoestrogens in foods using automated solid-phase extraction and LC/MS/MS
    Kuhnle, Gunter G. C.
    Dell'Aquila, Caterina
    Low, Yen-Ling
    Kussmaul, Michaela
    Bingham, Sheila A.
    ANALYTICAL CHEMISTRY, 2007, 79 (23) : 9234 - 9239
  • [5] Quantification of limonin in human urine using solid-phase extraction by LC-MS/MS
    Liu, Shijia
    Zhang, Jun
    Zhou, Ling
    Yu, Boyang
    Li, Changyin
    Liu, Zixiu
    Ju, Wenzheng
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 907 : 163 - 167
  • [6] Development and validation of protocols for solid-phase extraction coupled to LC and LC-MS
    Ooms, JAB
    Van Gils, GJM
    Duinkerken, AR
    Halmingh, O
    AMERICAN LABORATORY, 2000, 32 (18) : 52 - +
  • [7] Simultaneous Screening and Quantification of 29 Drugs of Abuse in Oral Fluid by Solid-Phase Extraction and Ultraperformance LC-MS/MS
    Badawi, Nora
    Simonsen, Kirsten Wiese
    Steentoft, Anni
    Bernhoft, Inger Marie
    Linnet, Kristian
    CLINICAL CHEMISTRY, 2009, 55 (11) : 2004 - 2018
  • [9] Automated method to determine pharmaceutical compounds in wastewater using on-line solid-phase extraction coupled to LC-MS/MS
    Marasco Junior, Cesar Augusto
    da Silva, Bianca Ferreira
    Lamarca, Rafaela Silva
    Feitosa de Lima Gomes, Paulo Clairmont
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (20) : 5147 - 5160
  • [10] Automated method to determine pharmaceutical compounds in wastewater using on-line solid-phase extraction coupled to LC-MS/MS
    César Augusto Marasco Júnior
    Bianca Ferreira da Silva
    Rafaela Silva Lamarca
    Paulo Clairmont Feitosa de Lima Gomes
    Analytical and Bioanalytical Chemistry, 2021, 413 : 5147 - 5160