Assessment of vessel permeability by combining dynamic contrast-enhanced and arterial spin labeling MRI

被引:5
作者
Liu, Ho-Ling [1 ,2 ]
Chang, Ting-Ting [1 ]
Yan, Feng-Xian [1 ,3 ]
Li, Cheng-He [1 ]
Lin, Yu-Shi [1 ]
Wong, Alex M. [4 ,5 ]
机构
[1] Chang Gung Univ, Dept Med Imaging & Radiol Sci, Coll Med, Taoyuan, Taiwan
[2] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[3] Taipei Med Univ, Dept Radiol, Shuang Ho Hosp, New Taipei City, Taiwan
[4] Chang Gung Mem Hosp Keelong, Dept Med Imaging & Intervent, Linkou Med Ctr, Keelung, Taiwan
[5] Chang Gung Univ, Coll Med, Taoyuan, Taiwan
关键词
MRI; permeability; forward volumetric transfer constant (K-trans); dynamic contrast enhanced (DCE); arterial spin labeling (ASL); BRAIN-BARRIER PERMEABILITY; CEREBRAL BLOOD-VOLUME; TRACER KINETICS; QUANTITATIVE MEASUREMENT; T-1-WEIGHTED MRI; PERFUSION; TUMORS; REQUIREMENTS; TISSUE; MODEL;
D O I
10.1002/nbm.3297
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The forward volumetric transfer constant (K-trans), a physiological parameter extracted from dynamic contrast-enhanced (DCE) MRI, is weighted by vessel permeability and tissue blood flow. The permeabilityxsurface area product per unit mass of tissue (PS) in brain tumors was estimated in this study by combining the blood flow obtained through pseudo-continuous arterial spin labeling (PCASL) and K-trans obtained through DCE MRI. An analytical analysis and a numerical simulation were conducted to understand how errors in the flow and K-trans estimates would propagate to the resulting PS. Fourteen pediatric patients with brain tumors were scanned on a clinical 3-T MRI scanner. PCASL perfusion imaging was performed using a three-dimensional (3D) fast-spin-echo readout module to determine blood flow. DCE imaging was performed using a 3D spoiled gradient-echo sequence, and the K-trans map was obtained with the extended Tofts model. The numerical analysis demonstrated that the uncertainty of PS was predominantly dependent on that of K-trans and was relatively insensitive to the flow. The average PS values of the whole tumors ranged from 0.006 to 0.217min(-1), with a mean of 0.050min(-1) among the patients. The mean K-trans value was 18% lower than the PS value, with a maximum discrepancy of 25%. When the parametric maps were compared on a voxel-by-voxel basis, the discrepancies between PS and K-trans appeared to be heterogeneous within the tumors. The PS values could be more than two-fold higher than the K-trans values for voxels with high K-trans levels. This study proposes a method that is easy to implement in clinical practice and has the potential to improve the quantification of the microvascular properties of brain tumors. Copyright (c) 2015 John Wiley & Sons, Ltd.
引用
收藏
页码:642 / 649
页数:8
相关论文
共 40 条
  • [21] Effects of the apparent transverse relaxation time on cerebral blood flow measurements obtained by arterial spin labeling
    Lawrence, KSS
    Wang, J
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (02) : 425 - 433
  • [22] Mills SJ, 2006, AM J NEURORADIOL, V27, P853
  • [23] Modeling of Contrast Agent Kinetics in the Lung Using T1-Weighted Dynamic Contrast-Enhanced MRI
    Naish, Josephine H.
    Kershaw, Lucy E.
    Buckley, David L.
    Jackson, Alan
    Waterton, John C.
    Parker, Geoffrey J. M.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (06) : 1507 - 1514
  • [24] Tumor vascular leakiness and blood volume estimates in oligodendrogliomas using perfusion CT: an analysis of perfusion parameters helping further characterize genetic subtypes as well as differentiate from astroglial tumors
    Narang, Jayant
    Jain, Rajan
    Scarpace, Lisa
    Saksena, Sona
    Schultz, Lonni R.
    Rock, Jack P.
    Rosenblum, Mark
    Patel, Suresh C.
    Mikkelsen, Tom
    [J]. JOURNAL OF NEURO-ONCOLOGY, 2011, 102 (02) : 287 - 293
  • [25] PARKER GJM, 2005, DYNAMIC CONTRAST ENH, P81
  • [26] TRANSPORT OF POTASSIUM-42 FROM BLOOD TO TISSUE IN ISOLATED MAMMALIAN SKELETAL MUSCLES
    RENKIN, EM
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1959, 197 (06): : 1205 - 1210
  • [27] Roberts HC, 2000, AM J NEURORADIOL, V21, P891
  • [28] Physiologic measurements by contrast-enhanced MR imaging: Expectations and limitations
    Roberts, TPL
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (01) : 82 - 90
  • [29] Comparative Evaluation of 3-Dimensional Pseudocontinuous Arterial Spin Labeling With Dynamic Contrast-Enhanced Perfusion Magnetic Resonance Imaging in Grading of Human Glioma
    Roy, Bhaswati
    Awasthi, Rishi
    Bindal, Amit
    Sahoo, Prativa
    Kumar, Rajan
    Behari, Sanjay
    Ojha, Bal K.
    Husain, Nuzhat
    Pandey, Chandra M.
    Rathore, Ram K. S.
    Gupta, Rakesh Kumar
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (03) : 321 - 326
  • [30] A unified impulse response model for DCE-MRI
    Schabel, Matthias C.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (05) : 1632 - 1646