Biomechanical study of prophylactic internal fixation of the radial osteocutaneous donor site using the sheep tibia model

被引:6
作者
Avery, C. M. E. [1 ]
Best, A.
Patterson, P.
Rolton, J.
Ponter, A. R. S.
机构
[1] Univ Hosp Leicester, Dept Maxillofacial Surg, Leicester LE1 5WW, Leics, England
[2] Univ Hosp Leicester, Dept Orthopaed Surg, Leicester LE1 5WW, Leics, England
[3] Univ Leicester, Dept Engn, Leicester LE1 5WW, Leics, England
关键词
free flap; radius; donor site; morbidity; fracture; internal fixation; plate;
D O I
10.1016/j.bjoms.2006.10.010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study investigated the strengthening effect of different types of plate and position after osteotomy of the sheep tibia, which is a model for the radial osteocutaneous donor site. Fifty matched pairs of adult sheep tibias were tested in torsion and four-point bending. Firstly, the weakening effect of an osteotomy was compared with the intact bone. Then pairs of bones with an osteotomy were compared with and without reinforcement with different types of 3.5 mm plate. The plate was placed in either the anterior (over the defect) or posterior (on the intact cortex) position. In torsion the mean strength of the intact bone was 45% greater than after osteotomy (P = 0.02). The reinforced bone was on average 61% stronger than the unreinforced bone (P < 0.001). In bending the mean strength of the intact bone was 188% greater than after osteotomy (P= 0.02). The reinforced bone was on average 184% stronger then the unreinforced bone (P < 0.001). The tibia was able to withstand much greater loads in bending. The dynamic compression plate was the strongest reinforcement in both torsion and bending. The position of the plate did not alter the strengthening effect in torsion but the posterior position resisted greater bending loads (P = 0.01). This may not be relevant in clinical practice as the radius is likely to fracture first as a result of lower torsional forces. (C) 2006 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:441 / 446
页数:6
相关论文
共 25 条
[1]  
AVERY C, 2006, IN PRESS BR J ORAL M
[2]   Osteocutaneous radial forearm free flaps - The necessity of internal fixation of the donor-site defect to prevent pathological fracture [J].
Bowers, KW ;
Edmonds, JL ;
Girod, DA ;
Jayaraman, G ;
Chua, CP ;
Toby, EB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (05) :694-704
[3]   BIOMECHANICS OF TORSIONAL FRACTURES - STRESS CONCENTRATION EFFECT OF A DRILL HOLE [J].
BROOKS, DB ;
BURSTEIN, AH ;
FRANKEL, VH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1970, A 52 (03) :507-&
[4]   EFFECT OF BIOPSY-HOLE SHAPE AND SIZE ON BONE STRENGTH [J].
CLARK, CR ;
MORGAN, C ;
SONSTEGARD, DA ;
MATTHEWS, LS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (02) :213-217
[5]   Fracture of the radial donor site after composite free flap harvest: a ten-year review [J].
Clark, S ;
Greenwood, M ;
Banks, RJ ;
Parker, P .
SURGEON-JOURNAL OF THE ROYAL COLLEGES OF SURGEONS OF EDINBURGH AND IRELAND, 2004, 2 (05) :281-286
[6]  
Frankel V.H., 1965, BIOMECHANICS RELATED, P381
[7]   STRUCTURAL CONSEQUENCES OF TRANSCORTICAL HOLES IN LONG BONES LOADED IN TORSION [J].
HIPP, JA ;
EDGERTON, BC ;
AN, KN ;
HAYES, WC .
JOURNAL OF BIOMECHANICS, 1990, 23 (12) :1261-1268
[8]   Radial forearm osteocutaneous free flap in maxillofacial and oromandibular reconstructions [J].
Kim, JH ;
Rosenthal, EL ;
Ellis, T ;
Wax, MK .
LARYNGOSCOPE, 2005, 115 (09) :1697-1701
[9]  
Li S., 2000, ORTHOPAEDIC BASIC SC, P181
[10]   Radioulnar load-sharing in the forearm - A study in cadavera [J].
Markolf, KL ;
Lamey, D ;
Yang, S ;
Meals, R ;
Hotchkiss, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (06) :879-888