The purpose of this study was to use quantitative computed tomography (CT) to estimate liver volume in dogs with a portosystemic shunt and to compare the liver volume in normal dogs to dogs with a shunt. Twenty-one dogs with a portosystemic shunt underwent contrast-enhanced abdominal CT for shunt characterization and preoperative planning. Six dogs without clinical signs relating to liver disease were used as a control group. In addition, liver volume was compared before and 2-4 months after surgical shunt attenuation in three dogs. All studies followed established clinical imaging protocols. Liver margins were defined on each image using an operator-defined region of interest and hepatic volume renderings were produced from which the liver volume was quantitatively estimated. There was a statistically significant association between liver volume and body weight in control and shunt dogs (r = 0.909 and 0.899, respectively, P < 0.01). Liver volume normalized to body weight was 15.5 +/- 5.2 cm(3)/kg in affected dogs and 24.5 +/- 5.6 cm(3)/kg in control dogs. Based on postligation CT studies in three affected dogs, liver volume increased by 43%, 51%, and 62%. Hepatic volume estimation may be a clinically useful parameter in the initial and postsurgical evaluation of dogs with portosystemic shunts.
引用
收藏
页码:409 / 413
页数:5
相关论文
共 20 条
[1]  
[Anonymous], 1993, MILLERS ANATOMY DOG
[2]   ULTRASONOGRAPHIC ASSESSMENT OF LIVER SIZE IN THE DOG [J].
BARR, F .
JOURNAL OF SMALL ANIMAL PRACTICE, 1992, 33 (08) :359-364
[3]   VOLUME DETERMINATIONS USING COMPUTED-TOMOGRAPHY [J].
BREIMAN, RS ;
BECK, JW ;
KOROBKIN, M ;
GLENNY, R ;
AKWARI, OE ;
HEASTON, DK ;
MOORE, AV ;
RAM, PC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 138 (02) :329-333
[4]  
BURK RL, 2003, SMALL ANIMAL RADIOLO, P249
[5]  
Center S. A., 1996, Strombeck's small animal gastroenterology, by W. G. Guilford et al., P802
[6]   Normal organ volume assessment from abdominal CT [J].
Geraghty, EM ;
Boone, JM ;
McGahan, JP ;
Jain, K .
ABDOMINAL IMAGING, 2004, 29 (04) :482-490
[7]   QUANTITATIVE ULTRASONIC ASSESSMENT OF LIVER SIZE IN THE DOG [J].
GODSHALK, CP ;
BADERTSCHER, RR ;
RIPPY, MK ;
GHENT, AW .
VETERINARY RADIOLOGY, 1988, 29 (04) :162-167
[8]   MEASUREMENT OF LIVER AND SPLEEN VOLUME BY COMPUTED-TOMOGRAPHY - ASSESSMENT OF REPRODUCIBILITY AND CHANGES FOUND FOLLOWING A SELECTIVE DISTAL SPLENORENAL SHUNT [J].
HENDERSON, JM ;
HEYMSFIELD, SB ;
HOROWITZ, J ;
KUTNER, MH .
RADIOLOGY, 1981, 141 (02) :525-527
[9]   ACCURATE MEASUREMENT OF LIVER, KIDNEY, AND SPLEEN VOLUME AND MASS BY COMPUTERIZED AXIAL-TOMOGRAPHY [J].
HEYMSFIELD, SB ;
FULENWIDER, T ;
NORDLINGER, B ;
BARLOW, R ;
SONES, P ;
KUTNER, M .
ANNALS OF INTERNAL MEDICINE, 1979, 90 (02) :185-187
[10]   Liver volume measurement by spiral CT - An in vitro study [J].
Kayaalp, C ;
Arda, K ;
Oto, A ;
Oran, M .
CLINICAL IMAGING, 2002, 26 (02) :122-124