Clinical experience with a novel subcutaneous implantable defibrillator system in a single center

被引:70
作者
Abkenari, Lara Dabiri [2 ]
Theuns, Dominic A. M. J. [2 ]
Valk, Suzanne D. A. [2 ]
Van Belle, Yves [2 ]
de Groot, Natasja M. [2 ]
Haitsma, David [2 ]
Muskens-Heemskerk, Agnes [2 ]
Szili-Torok, Tamas [2 ]
Jordaens, Luc [1 ]
机构
[1] Erasmus MC, Dept Electrophys, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus MC, Dept Cardiol, NL-3000 CA Rotterdam, Netherlands
关键词
Defibrillator; Sudden cardiac death; Ventricular fibrillation; Ventricular tachycardia; Arrhythmias; CARDIOVERTER-DEFIBRILLATOR; DUAL-CHAMBER; PREVENTION;
D O I
10.1007/s00392-011-0303-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Implantable cardioverter-defibrillators (ICDs) reduce mortality in both primary and secondary prevention, but are associated with substantial short- and long-term morbidity. A totally subcutaneous ICD (S-ICD) system has been developed. We report the initial clinical experience of the first 31 patients implanted at our hospital. All patients had an ICD indication according to the ACC/AHA/ESC guidelines. The first 11 patients were part of the reported CE trial. The implantation was performed without fluoroscopy. The device was implanted subcutaneously in the anterior axillary line, with a parasternal lead tunneled from the xiphoid to the manubrial-sternal junction. Ventricular fibrillation (VF) was induced to assess detection accuracy and defibrillation efficacy using 65 J shocks. Post-implant, 52 sustained episodes of VF were induced. Sensitivity was 100% and induced conversion efficacy was 100% (with standard polarity in 29 patients). Mean time to therapy was 13.9 +/- A 2.5 s (range 11-21.6 s). Late procedure-related complications were observed in 2 of the first 11 implantations (lead migration). During follow-up, spontaneous ventricular arrhythmias occurred in four patients, with accurate detection of all episodes. Inappropriate therapy was observed in five patients. Recurrences were prevented with reprogramming. The S-ICD system can be implanted without the use of fluoroscopy by using anatomical landmarks only. Episodes of VF were accurately detected using subcutaneous signals, and all induced and clinical episodes were successfully converted. The S-ICD system is a viable alternative to conventional ICD systems for selected patients.
引用
收藏
页码:737 / 744
页数:8
相关论文
共 15 条
[1]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[2]   An Entirely Subcutaneous Implantable Cardioverter-Defibrillator [J].
Bardy, Gust H. ;
Smith, Warren M. ;
Hood, Margaret A. ;
Crozier, Ian G. ;
Melton, Iain C. ;
Jordaens, Luc ;
Theuns, Dominic ;
Park, Robert E. ;
Wright, David J. ;
Connelly, Derek T. ;
Fynn, Simon P. ;
Murgatroyd, Francis D. ;
Sperzel, Johannes ;
Neuzner, Joerg ;
Spitzer, Stefan G. ;
Ardashev, Andrey V. ;
Oduro, Amo ;
Boersma, Lucas ;
Maass, Alexander H. ;
Van Gelder, Isabelle C. ;
Wilde, Arthur A. ;
van Dessel, Pascal F. ;
Knops, Reinoud E. ;
Barr, Craig S. ;
Lupo, Pierpaolo ;
Cappato, Riccardo ;
Grace, Andrew A. .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (01) :36-44
[3]   Inappropriate implantable cardioverter-defibrillator shocks due to temporary epicardial pacing [J].
Gelissen, Marloes ;
Debie, Luuk ;
van Opstal, Jurren .
EUROPACE, 2010, 12 (11) :1648-1648
[4]   Antitachycardia pacing for spontaneous rapid ventricular tachycardia in patients with prophylactic cardioverter-defibrillator therapy [J].
Grimm, Wolfram ;
Plachta, Eveline ;
Maisch, Bernhard .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (07) :759-764
[5]  
Hauser RG, 2006, HEART RHYTHM, V3, P640, DOI 10.1016/j.hrthm.2006.02.011
[6]   Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of > 10 years [J].
Kleemann, Thomas ;
Becker, Torsten ;
Doenges, Klaus ;
Vater, Margit ;
Senges, Jochen ;
Schneider, Steffen ;
Saggau, Werner ;
Weisse, Udo ;
Seidl, Karlheinz .
CIRCULATION, 2007, 115 (19) :2474-2480
[7]   Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia [J].
Moss, AJ ;
Hall, WJ ;
Cannom, DS ;
Daubert, JP ;
Higgins, SL ;
Klein, H ;
Levine, JH ;
Saksena, S ;
Waldo, AL ;
Wilber, D ;
Brown, MW ;
Heo, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 335 (26) :1933-1940
[8]   Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction [J].
Moss, AJ ;
Zareba, W ;
Hall, WJ ;
Klein, H ;
Wilber, DJ ;
Cannom, DS ;
Daubert, JP ;
Higgins, SL ;
Brown, MW ;
Andrews, ML .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (12) :877-883
[9]   A randomized comparison of atrial and dual-chamber pacing in 177 consecutive patients with sick sinus syndrome - Echocardiographic and clinical outcome [J].
Nielsen, JC ;
Kristensen, L ;
Andersen, HR ;
Mortensen, PT ;
Pedersen, OL ;
Pedersen, AK .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (04) :614-623
[10]   Infection after ICD implantation: operating room versus cardiac catheterisation laboratory [J].
Remmelts, H. H. F. ;
Meine, M. ;
Loh, P. ;
Hauer, R. N. W. ;
Doevendans, P. A. ;
van Herwerden, L. A. ;
Hopmans, T. E. M. ;
Ellerbroek, P. M. .
NETHERLANDS HEART JOURNAL, 2009, 17 (03) :95-100