Evaluating Internal Resonances in Power Transformers by Using Instrumental Variable Vector Fitting

被引:0
作者
Rodrigues, Lucas F. M. [1 ]
Schumacher, Ricardo [1 ]
Oliveira, Gustavo H. C. [1 ]
Rocha, Angelica C. O. [2 ]
Santo, Diogo J. D. E. [3 ]
机构
[1] Univ Fed Parana, Elect Engn Dept, Curitiba, PR, Brazil
[2] COPPEX, Belo Horizonte, MG, Brazil
[3] ESBR Energia Sustentavel Brasil, Porto Vellio, RO, Brazil
来源
2019 IEEE MILAN POWERTECH | 2019年
关键词
Black-Box Modeling; Vector Fitting; Instrumental Variables; Power Transformers; Electromagnetic Transients Simulation; RATIONAL APPROXIMATION;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Procedures for modeling potential/ power transformers and reactors in order to support electromagnetic transients analysis have been addressed by many recent researchers. Among all methods for obtaining black-box models, the Frequency Domain Vector Fitting (FD-VF) or, simply VF, has several successful application reports in electrical power systems. This article is two purpose: first to describe a procedure that combines instrumental variables to the VF method, called the Instrumental Variable VF (IV-VF). The main advantage of the IV-VF is the fact that if the iterative procedure converged, an optimal local solution is obtained. Also to present a case study based on actual single-phase transformer measurements (Benchmark JWG A2/C4.52 for Power Transformers) and a GIS installation, where IV-VF is used for evaluating internal resonances in power transformers due to high frequency transients. The knowledge of external and internal winding response to these transients contribute to insulation design and reliability in field operation.
引用
收藏
页数:6
相关论文
共 18 条
[11]   Measurements for validation of manufacturer's white-box transformer models [J].
Gustavsen, Bjorn ;
Portillo, Alvaro ;
Ronchi, Rodrigo ;
Mjelve, Asgeir .
SPECIAL ISSUE OF THE 4TH INTERNATIONAL COLLOQUIUM -TRANSFORMER RESEARCH AND ASSET MANAGEMENT, 2017, 202 :240-250
[12]  
Hori M., 2007, IEEE PES GEN M
[13]   Modeling guidelines for fast front transients [J].
Imece, AF ;
Durbak, DW ;
Elahi, H ;
Kolluri, S ;
Lux, A ;
Mader, D ;
McDermott, TE ;
Morched, A ;
Mousa, AM ;
Natarajan, R ;
Rugeles, L ;
Tarasiewicz, E .
IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (01) :493-506
[14]   Analysing a power transformer's internal response to system transients using a hybrid modelling methodology [J].
Mitchell, Steven D. ;
Oliveira, Gustavo H. C. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 69 :67-75
[15]  
Schumacher R., 2019, ELECT POWER ENERGY S, V104
[16]  
Schumacher R., 2018, SYSTEM SIGNAL PROCES, V37
[17]   Transformer Failure Due to Circuit-Breaker-Induced Switching Transients [J].
Shipp, David D. ;
Dionise, Thomas J. ;
Lorch, Visuth ;
MacFarlane, Bill G. .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2011, 47 (02) :707-718
[18]   Experimental Research on Very-Fast Transient Overvoltage in 1100-kV Gas-Insulated Switchgear [J].
Shu, Yinbiao ;
Chen, Weijiang ;
Li, Zhibing ;
Dai, Min ;
Li, Chengrong ;
Liu, Weidong ;
Yan, Xianglian .
IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (01) :458-466