Optimization of a chemical modifier in the determination of selenium by graphite furnace atomic absorption spectrometry and its application to wheat and wheat hour analysis

被引:4
作者
Alexiu, V
Vladescu, L
机构
[1] Magistra C&C, Constanta 900133, Romania
[2] Univ Bucharest, Bucharest 030018, Romania
关键词
D O I
10.2116/analsci.21.137
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for the determination of total selenium in wheat and wheat flour using graphite furnace atomic absorption spectrometry (GFAAS) with palladium/ascorbic acid as a chemical modifier was studied. The effects of nickel nitrate, palladium/ascorbic acid, and palladium/magnesium nitrate as chemical modifiers on the sensitivity in the determination of selenite, selenate and selenomethionine by GFAAS were compared. The palladium/ascorbic acid modifier was used for the determination of total selenium in Wheat and wheat flour, because the oxidation states of the selenium ion are not important in the determination. The detection limit was estimated to be 1 mug L-1 (calculated as 3sigma of the blank); the calibration curve was linear for the concentration range 5 - 50 mug L-1 and the recovery range was 96.66 - 101.80%. The optimal ashing and atomizing temperatures were 1300degreesC and 2250degreesC, respectively. The proposed method was successfully applied to the determination of total selenium in wheat and wheat flour.
引用
收藏
页码:137 / 141
页数:5
相关论文
共 36 条
[1]   Evidence of low selenium concentrations in UK bread-making wheat grain [J].
Adams, ML ;
Lombi, E ;
Zhao, FJ ;
McGrath, SP .
JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2002, 82 (10) :1160-1165
[2]   CRITICAL-EVALUATION OF SOME WET DIGESTION METHODS FOR THE STRIPPING VOLTAMMETRIC DETERMINATION OF SELENIUM IN BIOLOGICAL-MATERIALS [J].
ADELOJU, SB ;
BOND, AM ;
BRIGGS, MH .
ANALYTICAL CHEMISTRY, 1984, 56 (13) :2397-2401
[3]   DETERMINATION OF SELENIUM BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY UTILIZING A NEW HYDRIDE GENERATION SAMPLE INTRODUCTION SYSTEM [J].
BUCKLEY, WT ;
BUDAC, JJ ;
GODFREY, DV ;
KOENIG, KM .
ANALYTICAL CHEMISTRY, 1992, 64 (07) :724-729
[4]   Hydride generation atomic fluorescence spectrometric determination of ultratraces of selenium and tellurium in cow milk [J].
Cava-Montesinos, P ;
Cervera, ML ;
Pastor, A ;
de la Guardia, M .
ANALYTICA CHIMICA ACTA, 2003, 481 (02) :291-300
[5]  
Dedina J, 1996, SPECTROCHIM ACTA B, V51, P1107
[6]   THE DETERMINATION OF ARSENIC AND SELENIUM IN COAL BY CONTINUOUS-FLOW HYDRIDE-GENERATION ATOMIC-ABSORPTION SPECTROMETRY AND ATOMIC FLUORESCENCE SPECTROMETRY [J].
EBDON, L ;
WILKINSON, JR .
ANALYTICA CHIMICA ACTA, 1987, 194 :177-187
[7]   Comparison of palladium chemical modifiers for the determination of selenium in plasma by Zeeman-effect background corrected electrothermal atomic absorption spectrometry [J].
Gammelgaard, B ;
Jons, O .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (04) :465-470
[8]   SELENIUM IN SOILS AND PLANTS AND ITS IMPORTANCE IN LIVESTOCK AND HUMAN-NUTRITION [J].
GISSELNIELSEN, G ;
GUPTA, UC ;
LAMAND, M ;
WESTERMARCK, T .
ADVANCES IN AGRONOMY, 1984, 37 :397-460
[9]  
IHNAT M, 1974, J ASSOC OFF ANA CHEM, V57, P373
[10]   Determination of cadmium, lead and selenium in Medicago sativa herb by differential pulse stripping voltammetry [J].
Inam, R ;
Somer, G ;
Küçükoglu, B .
ANALYTICAL SCIENCES, 1999, 15 (05) :493-496