3-D US frame positioning using speckle decorrelation and image registration

被引:18
作者
Chang, RF
Wu, WJ
Chen, DR
Chen, WM
Shu, W
Lee, JH
Jeng, LB
机构
[1] China Med Coll & Hosp, Dept Gen Surg, Taichung, Taiwan
[2] Natl Chung Cheng Univ, Dept Comp Sci & Informat Engn, Chiayi, Taiwan
关键词
speckle decorrelation; image registration; frame positioning; 3-D ultrasound;
D O I
10.1016/S0301-5629(03)00036-X
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this paper, a new positioning system is proposed for the 3-D ultrasound (US). This system combines the image registration technique and speckle decorrelation algorithm to accurately position sequential ultrasonic images without any additional positioning hardware. The speckle decorrelation algorithm estimates the relative distance of two neighboring frames and the image registration technique gets the range of the whole 3-D ultrasonic data set and makes slight modification on each frame's position. The image registration technique is based on the reference image, which is perpendicular to the 3-D ultrasonic data set. This reference image intersects each frame of the 3-D ultrasonic data set in a line. For each frame, the intersectional line is first found and then the location in the reference image can be used to estimate the position of this frame. This system uses the data set of consecutive 2-D freehand-scanned US B-mode images to construct the 3-D US volume data, and it can be integrated into the 3-D US volume rendering system. (E-mail: dichen88@ms13.hinet.net) (C) 2003 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:801 / 812
页数:12
相关论文
共 18 条
[11]   PREPROCESSING AND VOLUME RENDERING OF 3D ULTRASONIC DATA [J].
SAKAS, G ;
SCHREYER, LA ;
GRIMM, M .
IEEE COMPUTER GRAPHICS AND APPLICATIONS, 1995, 15 (04) :47-54
[12]   Image guidance of breast cancer surgery using 3-D ultrasound images and augmented reality visualization [J].
Sato, Y ;
Nakamoto, M ;
Tamaki, Y ;
Sasama, T ;
Sakita, I ;
Nakajima, Y ;
Monden, M ;
Tamura, S .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :681-693
[13]   Optimum scan spacing for three-dimensional ultrasound by speckle statistics [J].
Smith, WL ;
Fenster, A .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (04) :551-562
[14]  
Studholme C, 1996, Med Image Anal, V1, P163, DOI 10.1016/S1361-8415(96)80011-9
[15]   REGISTRATION OF 3D OBJECTS AND SURFACES [J].
TOENNIES, KD ;
UDUPA, JK ;
HERMAN, GT ;
WORNOM, IL ;
BUCHMAN, SR .
IEEE COMPUTER GRAPHICS AND APPLICATIONS, 1990, 10 (03) :52-62
[16]   Automated three-dimensional US frame positioning computed from elevational speckle decorrelation [J].
Tuthill, TA ;
Krücker, JF ;
Fowlkes, JB ;
Carson, PL .
RADIOLOGY, 1998, 209 (02) :575-582
[17]   Three-dimensional surface reconstruction using optical flow for medical imaging [J].
Weng, N ;
Yang, YH ;
Pierson, R .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (05) :630-641
[18]  
ZUBAL G, 1991, ANN INT C IEEE ENG M, P293