In this paper, a new positioning system is proposed for the 3-D ultrasound (US). This system combines the image registration technique and speckle decorrelation algorithm to accurately position sequential ultrasonic images without any additional positioning hardware. The speckle decorrelation algorithm estimates the relative distance of two neighboring frames and the image registration technique gets the range of the whole 3-D ultrasonic data set and makes slight modification on each frame's position. The image registration technique is based on the reference image, which is perpendicular to the 3-D ultrasonic data set. This reference image intersects each frame of the 3-D ultrasonic data set in a line. For each frame, the intersectional line is first found and then the location in the reference image can be used to estimate the position of this frame. This system uses the data set of consecutive 2-D freehand-scanned US B-mode images to construct the 3-D US volume data, and it can be integrated into the 3-D US volume rendering system. (E-mail: dichen88@ms13.hinet.net) (C) 2003 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:801 / 812
页数:12
相关论文
共 18 条
[1]   Three-dimensional freehand ultrasound: Image reconstruction and volume analysis [J].
Barry, CD ;
Allott, CP ;
John, NW ;
Mellor, PM ;
Arundel, PA ;
Thomson, DS ;
Waterton, JC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (08) :1209-1224
[2]  
Chen JF, 1997, INT J IMAG SYST TECH, V8, P38, DOI 10.1002/(SICI)1098-1098(1997)8:1<38::AID-IMA5>3.0.CO
[3]  
2-U
[4]   3D free-form surface registration and object recognition [J].
Chua, CS ;
Jarvis, R .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1996, 17 (01) :77-99
[5]   REGISTRATION OF MR AND CT IMAGES FOR SKULL BASE SURGERY USING POINT-LIKE ANATOMICAL FEATURES [J].
HILL, DLG ;
HAWKES, DJ ;
CROSSMAN, JE ;
GLEESON, MJ ;
COX, TCS ;
BRACEY, EECML ;
STRONG, AJ ;
GRAVES, P .
BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (767) :1030-1035
[6]   BACKSCATTER COEFFICIENT ESTIMATION USING ARRAY TRANSDUCERS [J].
INSANA, MF ;
HALL, TJ ;
COOK, LT .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1994, 41 (05) :714-723
[7]   3-D sonographic volume measurement of the cerebral ventricular system: In vitro validation [J].
Kampmann, W ;
Walka, MM ;
Vogel, M ;
Obladen, M .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (08) :1169-1174
[8]   Three-dimensional ultrasound imaging [J].
Nelson, TR ;
Pretorius, DH .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (09) :1243-1270
[9]   ACCURATE 3-DIMENSIONAL REGISTRATION OF CT, PET, AND OR MR IMAGES OF THE BRAIN [J].
PELIZZARI, CA ;
CHEN, GTY ;
SPELBRING, DR ;
WEICHSELBAUM, RR ;
CHEN, CT .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (01) :20-26
[10]   Automatic registration of 3-D ultrasound images [J].
Rohling, RN ;
Gee, AH ;
Berman, L .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (06) :841-854