Background: Displaced and shortened clavicular shaft fractures can be treated by intramedullary fixation; however, hardware migration and soft tissue irritation at the insertion site have complicated its use. The aim of this study was to determine whether the new Sonoma CRx intramedullary device (Sonoma Orthopedic Products Inc, Santa Rosa, CA, USA) could be used successfully to treat displaced and shortened clavicular shaft fractures and restore the functional capacity of shoulder without the development of secondary complications. Methods: Displaced and shortened clavicular shaft fractures in 47 consecutive patients were treated with the CRx device. Incision size was captured during the surgical procedure. The union rate was evaluated postoperatively. Shoulder function was assessed by Disabilities of the Arm, Shoulder and Hand (DASH) score, the Constant Shoulder Score, and a range of motion score. Patients were assessed after 3 to 6 months (group I), 6 to 9 months (group II), or 9 to 12 months (group III) postoperatively. Results: Union was achieved in all patients at the time of review, without any incidence of hardware migration. Postoperative complications developed in 3 patients, comprising infection in 1 and hardware failure in 2. No differences among the groups were found for the DASH score (P = .33), Constant Shoulder Score (P = .38), and range of motion score (P = .96). The DASH, Constant Shoulder, and range of motion scores were similar to other successful treatment options, such as plating. Conclusion: The Sonoma CRx is a good alternative device to treat displaced and shortened clavicular shaft fractures and restore the functional capacity of the shoulder. Future research should focus on when nailing and plating should be used to treat clavicular shaft fractures most optimally. (C) 2015 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:E1 / E6
页数:6
相关论文
共 24 条
[1]   Reconstruction plate versus minimal invasive retrograde titanium elastic nail fixation for displaced midclavicular fractures [J].
Assobhi J.E.H. .
Journal of Orthopaedics and Traumatology, 2011, 12 (4) :185-192
[2]  
CONSTANT CR, 1987, CLIN ORTHOP RELAT R, P160
[3]  
De Smet L, 2008, ACTA ORTHOP BELG, V74, P575
[4]   Plating versus intramedullary pin or conservative treatment for midshaft fracture of clavicle: a meta-analysis of randomized controlled trials [J].
Duan, Xin ;
Zhong, Gang ;
Cen, Shiqiang ;
Huang, Fuguo ;
Xiang, Zhou .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (06) :1008-1015
[5]   Locked intramedullary fixation vs plating for displaced and shortened mid-shaft clavicle fractures: A randomized clinical trial [J].
Ferran, Nicholas A. ;
Hodgson, Paul ;
Vannet, Nicola ;
Williams, Rhys ;
Evans, Richard O. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (06) :783-789
[6]   Anatomical Reduction for Treatment of Displaced Midshaft Clavicular Fractures: Knowles Pinning Vs Reconstruction Plating [J].
Fu, Te-Hu ;
Tan, Boon-Lee ;
Liu, Hao-Chen ;
Wang, Jun-Wen .
ORTHOPEDICS, 2012, 35 (01) :E23-E30
[7]   Closed treatment of displaced middle-third fractures of the clavicle gives poor results [J].
Hill, JM ;
McGuire, MH ;
Crosby, LA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (04) :537-539
[8]   Plate fixation versus intramedullary fixation for displaced mid-shaft clavicle fractures: a systematic review [J].
Houwert, R. Marijn ;
Wijdicks, Frans-Jasper ;
Bisschop, Charlotte Steins ;
Verleisdonk, Egbert-Jan ;
Kruyt, Moyo .
INTERNATIONAL ORTHOPAEDICS, 2012, 36 (03) :579-585
[9]  
Hudak PL, 1996, AM J IND MED, V29, P602, DOI 10.1002/(SICI)1097-0274(199606)29:6<602::AID-AJIM4>3.0.CO
[10]  
2-L