Solid-phase microextraction (SPME) analysis of short-chain aliphatic amines (C-3-C-6) in aqueous solutions was investigated using pentafluorobenzaldehyde (PFBAY) as on-fiber derivatization reagent. A standard gas generating vial agent was used for on-fiber loading of the derivatization agent so as to avoid the need for its regeneration at each derivatization cycle. Several parameters such as loading time, reaction temperature, and reaction/extraction time were optimized for headspace and direct sampling in aqueous solutions. Three different coating chemistries were tested and their performances compared in order to achieve the best compromise between sensitivity and analysis throughput. The newly developed PDMS/DVB/PDMS coating showed superior performance in terms of extraction efficiency while the capability to prevent on-fiber degradation of the derivatizing products. The optimized method was used for quantitation of short-chain aliphatic amines in aqueous samples and provided detection limits in the low ppb range for all the amines tested with accuracy values between 79 and 120%. The method was applied towards the analysis of environmental water samples and the accuracy of the results was evaluated by different calibration approaches. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:22 / 28
页数:7
相关论文
共 32 条
  • [21] Chemical Derivatization Processes Applied to Amine Determination in Samples of Different Matrix Composition
    Plotka-Wasylka, Justyna M.
    Morrison, Calum
    Biziuk, Marek
    Namiesnik, Jacek
    [J]. CHEMICAL REVIEWS, 2015, 115 (11) : 4693 - 4718
  • [22] Shirey RE, 2012, HANDBOOK OF SOLID PHASE MICROEXTRACTION, P99, DOI 10.1016/B978-0-12-416017-0.00004-8
  • [23] Optimization of Fiber Coating Structure Enables Direct Immersion Solid Phase Microextraction and High-Throughput Determination of Complex Samples
    Silva, Erica A. Souza
    Pawliszyn, Janusz
    [J]. ANALYTICAL CHEMISTRY, 2012, 84 (16) : 6933 - 6938
  • [24] Determination of aliphatic amines by gas chromatography-mass spectrometry after in-syringe derivatization with pentafluorobenzoyl chloride
    Singh, Deepesh Kumar
    Sanghi, Sunil Kumar
    Gowri, Sorna
    Chandra, Navin
    Sanghi, Shail Bala
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (33) : 5683 - 5687
  • [25] Methodical evaluation and improvement of matrix compatible PDMS-overcoated coating for direct immersion solid phase microextraction gas chromatography (DI-SPME-GC)-based applications
    Souza-Silva, Erica A.
    Gionfriddo, Emanuela
    Shirey, Robert
    Sidisky, Len
    Pawliszyn, Janusz
    [J]. ANALYTICA CHIMICA ACTA, 2016, 920 : 54 - 62
  • [26] Direct Immersion Solid-Phase Microextraction with Matrix-Compatible Fiber Coating for Multiresidue Pesticide Analysis of Grapes by Gas Chromatography-Time-of-Flight Mass Spectrometry (DI-SPME-GC-ToFMS)
    Souza-Silva, Erica A.
    Pawliszyn, Janusz
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2015, 63 (18) : 4464 - 4477
  • [27] Fast and robust direct immersion solid phase microextraction coupled with gas chromatography-time-of-flight mass spectrometry method employing a matrix compatible fiber for determination of triazole fungicides in fruits
    Souza-Silva, Erica A.
    Lopez-Avila, Viorica
    Pawliszyn, Janusz
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2013, 1313 : 139 - 146
  • [28] Trends in quality in the analytical laboratory. II. Analytical method validation and quality assurance
    Taverniers, I
    De Loose, M
    Van Bockstaele, E
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2004, 23 (08) : 535 - 552
  • [29] Sensitivity enhancement in the fluorometric determination of aliphatic amines using naphthalene-2,3-dicarboxaldehyde derivatization followed by vortex-assisted liquid-liquid microextraction
    Wang, Chin-Yi
    Tung, Shu-Yin
    Lo, Yu-Shiu
    Huang, Hsien-Lu
    Ko, Chun-Han
    Wu, Chien-Hou
    [J]. TALANTA, 2016, 152 : 475 - 481
  • [30] Equilibrium in-fibre standardisation technique for solid-phase microextraction
    Wang, YX
    O'Reilly, J
    Chen, Y
    Pawliszyn, J
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1072 (01) : 13 - 17