Evolution of thrombolytic therapy in patients with HeartWare ventricular assist device thrombosis: a single-institutional experience

被引:0
作者
Fox, Henrik [1 ,2 ]
Gyoten, Takayuki [1 ]
Rojas, Sebastian, V [1 ,2 ]
Lauenroth, Volker [1 ]
Guenther, Sabina [1 ]
Schramm, Rene [1 ,2 ]
Gummert, Jan F. [1 ,2 ]
Morshuis, Michiel [1 ,2 ]
机构
[1] Ruhr Univ Bochum, Herz & Diabeteszentrum NRW, Clin Thorac & Cardiovasc Surg, Bad Oeynhausen, Germany
[2] Ruhr Univ Bochum, Heart Failure Dept, Herz & Diabeteszentrum NRW, Bad Oeynhausen, Germany
关键词
Left ventricular assist devices; Thrombolysis; Pump thrombosis; Tissue plasminogen activator; Surgical pump exchange; HeartWare; PUMP THROMBOSIS; MANAGEMENT;
D O I
10.1093/icvts/ivac054
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: Pump thrombosis remains a major challenge in heart failure patients with left ventricular HeartWare assist device. Current International Society for Heart and Lung Transplantation recommendations favour surgical pump exchange over lysis because safety and efficacy of lysis has been controversially reported. This study summarizes our experience on our HeartWare thrombosis prevention strategy as well as thrombolysis through implementation of our institutional standardized HeartWare assist protocol. METHODS: Outcomes of all HeartWare thrombosis patients admitted between 2010 and 2020 were analysed. Thrombolysis therapy using tissue plasminogen activator was used as the first-line therapy in this study and thrombolysis therapy efficacy was defined as freedom from stroke, bleeding, recurrent HeartWare assist device thrombosis or surgical device exchange within 30 days after lysis application. RESULTS: A total of 507 patients have been included in this study and 66 patients (13%) collectively developed a first HeartWare-thrombosis after a median of 12 months (8-22 months) after HeartWare implantation. Forty patients were treated with unstandardized lysis, of whom 7 patients had thrombolysis associated complications, such as incomplete thrombus resolution requiring surgical pump exchange in 4 patients, but also intracranial haemorrhage occurring in 3 patients. Three patients died in the non-protocol group. Eight device thrombosis patients were treated according to our protocol, showing no lysis-associated complication. CONCLUSIONS: Despite current recommendations, preferring surgical HeartWare pump exchange in thrombosis, thrombolysis therapy for first HeartWare thrombosis can be safe and effective in a standardized protocol setting, including anticoagulation adjustment and intensified blood pressure control management.
引用
收藏
页数:9
相关论文
共 15 条
[1]   First-in-human high-density epicardial mapping and ablation through a left anterior minitnora-cotomy in an LVAD patient presenting in electrical storm: a case report [J].
El Hamriti, Mustapha ;
Fox, Henrik ;
Sommer, Philipp ;
Rojas, Sebastian, V .
EUROPEAN HEART JOURNAL-CASE REPORTS, 2021, 5 (06)
[2]   Permanent Implantable Cardiac Support Systems [J].
Gummert, Jan F. ;
Haverich, Axel ;
Schmitto, Jan D. ;
Potapov, Evgenij ;
Schramm, Rene ;
Falk, Volkmar .
DEUTSCHES ARZTEBLATT INTERNATIONAL, 2019, 116 (50) :843-848
[3]   Identification of characteristics, risk factors, and predictors of recurrent LVAD thrombosis: conditions in HeartWare devices [J].
Gyoten, Takayuki ;
Morshuis, Michiel ;
Rojas, Sebastian V. ;
Deutsch, Marcus-Andre ;
Schramm, Rene ;
Gummert, Jan F. ;
Fox, Henrik .
JOURNAL OF ARTIFICIAL ORGANS, 2021, 24 (02) :173-181
[4]   Patients with ventricular assist device and cerebral entrapment-Supporting skullcap reimplantation [J].
Gyoten, Takayuki ;
Rojas, Sebastian, V ;
Irimie, Anca ;
Schramm, Rene ;
Morshuis, Michiel ;
Gummert, Jan F. ;
Sitzer, Matthias ;
Fox, Henrik .
ARTIFICIAL ORGANS, 2021, 45 (05) :473-478
[5]   Facilitating heart transplantability in an end-stage heart failure patient with brain abscess and infected left ventricle assist device-A unique case report [J].
Ibrahim, Mohamad ;
Arafat, Shawqi ;
Rojas, Sebastian, V ;
Schramm, Rene ;
Gummert, Jan F. ;
Morshuis, Michiel ;
Fox, Henrik .
INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2020, 71 :213-216
[6]   Complications of left ventricular assist devices causing high urgency status on waiting list: impact on outcome after heart transplantation [J].
Immohr, Moritz Benjamin ;
Boeken, Udo ;
Mueller, Franziska ;
Prashovikj, Emir ;
Morshuis, Michiel ;
Boettger, Charlotte ;
Aubin, Hug ;
Gummert, Jan ;
Akhyari, Payam ;
Lichtenberg, Artur ;
Schramm, Rene .
ESC HEART FAILURE, 2021, 8 (02) :1253-1262
[7]   Management of HeartWare left ventricular assist device thrombosis using intracavitary thrombolytics [J].
Kiernan, Michael S. ;
Duc Thinh Pham ;
DeNofrio, David ;
Kapur, Navin K. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 142 (03) :712-714
[8]   American Association for Thoracic Surgery/International Society for Heart and Lung Transplantation guidelines on selected topics in mechanical circulatory support [J].
Kirklin, James K. ;
Pagani, Francis D. ;
Goldstein, Daniel J. ;
John, Ranjit ;
Rogers, Joseph G. ;
Atluri, Pavan ;
Arabia, Francisco A. ;
Cheung, Anson ;
Holman, William ;
Hoopes, Charles ;
Jeevanandam, Valuvan ;
Jorde, Ulrich P. ;
Milano, Carmelo A. ;
Moazami, Nader ;
Naka, Yoshifumi ;
Netuka, Ivan ;
Pamboukian, Salpy, V ;
Pinney, Sean ;
Selzman, Craig H. ;
Silverstry, Scott ;
Slaughter, Mark ;
Stulak, John ;
Teuteberg, Jeff ;
Vierecke, Juliane ;
Schueler, Stephan ;
D'Alessandro, David A. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2020, 39 (03) :187-219
[9]   The vexing problem of thrombosis in long-term mechanical circulatory support [J].
Mehra, Mandeep R. ;
Stewart, Garrick C. ;
Uber, Patricia A. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (01) :1-11
[10]   The Society of Thoracic Surgeons Intermacs 2020 Annual Report [J].
Molina, Ezequiel J. ;
Shah, Palak ;
Kiernan, Michael S. ;
Cornwell, William K., III ;
Copeland, Hannah ;
Takeda, Koji ;
Fernandez, Felix G. ;
Badhwar, Vinay ;
Habib, Robert H. ;
Jacobs, Jeffrey P. ;
Koehl, Devin ;
Kirklin, James K. ;
Pagani, Francis D. ;
Cowger, Jennifer A. .
ANNALS OF THORACIC SURGERY, 2021, 111 (03) :778-792