3D Monte Carlo dosimetry of intraoperative electron radiation therapy (IOERT)

被引:11
|
作者
Alhamada, Husein [1 ,2 ]
Simon, Stephane [1 ,2 ]
Philippson, Catherine [2 ]
Vandekerkhove, Christophe [2 ]
Jourani, Younes [2 ]
Pauly, Nicolas [1 ]
VanGestel, Dirk [2 ]
Reynaert, Nick [1 ,2 ]
机构
[1] Univ Libre Bruxelles, Ecole Polytech, Nucl Metrol, Brussels, Belgium
[2] Inst Jules Bordet, Radiotherapy Dept, Brussels, Belgium
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2019年 / 57卷
关键词
DOSE CALCULATIONS; RADIOTHERAPY; IORT; DISTRIBUTIONS; APPLICATOR; PHOTON;
D O I
10.1016/j.ejmp.2018.12.037
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This paper studies the feasibility of using Monte Carlo (MC) for treatment planning of intraoperative electron radiation therapy (IOERT) procedure to get 3D dose by using patient's CT images. Methods: The IOERT treatment planning was performed using the following successive steps: I) The Mobetron 1000 degrees machine was modelled with the EGSnrc MC codes. II) The MC model was validated with measurements of percentage depth doses and profiles for three energies (12, 9, 6) MeV. III) CT images were imported as DICOM files. IV) Contouring of the planning target volume (PTV) and the organs at risk was done by the radiation oncologist. V) The medical physicist with the radiation oncologist, had chosen the same parameters of IOERT procedures like energy, applicator (type, size) and using or not bolus. VI) Finally, dose calculation and analysis of 3D maps was carried out. Results: The tuning process of the MC model provides good results, as the maximum value of the root mean square deviation (RMSD) was less than 3% between the MC simulated PDDs and the measured PDDs. The contouring and dose analysis review were easy to conduct for the classical treatment planning system. The radiation oncologist had many tools for dose analysis such as DVH and color wash for all the slides. Summation of the 3D dose of IOERT with other radiotherapy plans is possible and helpful for total dose estimation. Archiving and documentation is as good as treatment planning system (TPS). Conclusions: The method displayed in this paper provides a step forward for IOERT Dosimetry and allows to obtain accurate dosimetry of treated volumes.
引用
收藏
页码:207 / 214
页数:8
相关论文
共 50 条
  • [41] Intra-Operative Electron Radiation Therapy (IOERT) Anticipated Boost in Breast Cancer Treatment: An Italian Multicenter Experience
    Ciabattoni, Antonella
    Gregucci, Fabiana
    Llange, Karen
    Alessandro, Marina
    Corazzi, Francesca
    Ivaldi, Giovanni B.
    Zuccoli, Paola
    Stefanelli, Antonio
    Cristaudo, Agostino
    Fusco, Vincenzo
    Lapadula, Loredana
    Fiorentino, Alba
    Di Cristino, Daniela
    Salerno, Francesca
    Lioce, Marco
    Krengli, Marco
    Vidali, Cristiana
    CANCERS, 2022, 14 (02)
  • [42] Monte Carlo assessment of low energy electron range in liquid water and dosimetry effects
    Seniwal, Baljeet
    Mendes, Bruno M.
    Malano, Francisco
    Perez, Pedro
    Valente, Mauro
    Fonseca, Telma C. F.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 80 : 363 - 372
  • [43] Monte Carlo modelling of acute and late effects in radiation therapy
    Hugtenburg, Richard P.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (07) : 1113 - 1117
  • [44] Minibeam radiation therapy for the management of osteosarcomas: A Monte Carlo study
    Martinez-Rovira, I.
    Prezado, Y.
    MEDICAL PHYSICS, 2014, 41 (06)
  • [45] 3D printer generated thorax phantom with mobile tumor for radiation dosimetry
    Mayer, Rulon
    Liacouras, Peter
    Thomas, Andrew
    Kang, Minglei
    Lin, Liyong
    Simone, Charles B., II
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (07)
  • [46] Monte Carlo as quality control tool of stereotactic body radiation therapy treatment plans
    Alhamada, Husein
    Simon, Stephane
    Gulyban, Akos
    Gastelblum, Pauline
    Pauly, Nicolas
    VanGestel, Dirk
    Reynaert, Nick
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 84 : 205 - 213
  • [47] Monte Carlo calculation of monitor unit for electron arc therapy
    Chow, James C. L.
    Jiang, Runqing
    MEDICAL PHYSICS, 2010, 37 (04) : 1571 - 1578
  • [48] Monte Carlo flattening filter design to high energy intraoperative electron beam homogenization
    Oliver, S.
    Vijande, J.
    Tejedor-Aguilar, N.
    Miro, R.
    Rovira-Escutia, Juan J.
    Ballester, F.
    Juste, B.
    Carmona, V.
    Felici, G.
    Verdu, G.
    Sanchis, E.
    Conde, A.
    Perez-Calatayud, J.
    RADIATION PHYSICS AND CHEMISTRY, 2023, 212
  • [49] Ultrasound-guided intraoperative electron beam radiation therapy: A phantom study
    Ma, Pan
    Li, Minghui
    Chen, Xinyuan
    Tian, Yuan
    Niu, Chuanmeng
    Feng, Qinfu
    Dai, Jianrong
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 78 : 1 - 7
  • [50] Monte Carlo simulation for internal radiation dosimetry based on the high resolution Visible Chinese Human
    Liu Yang
    Xie Tianwu
    Liu Qian
    NUCLEAR SCIENCE AND TECHNIQUES, 2011, 22 (03) : 165 - 173