3D Monte Carlo dosimetry of intraoperative electron radiation therapy (IOERT)

被引:11
|
作者
Alhamada, Husein [1 ,2 ]
Simon, Stephane [1 ,2 ]
Philippson, Catherine [2 ]
Vandekerkhove, Christophe [2 ]
Jourani, Younes [2 ]
Pauly, Nicolas [1 ]
VanGestel, Dirk [2 ]
Reynaert, Nick [1 ,2 ]
机构
[1] Univ Libre Bruxelles, Ecole Polytech, Nucl Metrol, Brussels, Belgium
[2] Inst Jules Bordet, Radiotherapy Dept, Brussels, Belgium
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2019年 / 57卷
关键词
DOSE CALCULATIONS; RADIOTHERAPY; IORT; DISTRIBUTIONS; APPLICATOR; PHOTON;
D O I
10.1016/j.ejmp.2018.12.037
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This paper studies the feasibility of using Monte Carlo (MC) for treatment planning of intraoperative electron radiation therapy (IOERT) procedure to get 3D dose by using patient's CT images. Methods: The IOERT treatment planning was performed using the following successive steps: I) The Mobetron 1000 degrees machine was modelled with the EGSnrc MC codes. II) The MC model was validated with measurements of percentage depth doses and profiles for three energies (12, 9, 6) MeV. III) CT images were imported as DICOM files. IV) Contouring of the planning target volume (PTV) and the organs at risk was done by the radiation oncologist. V) The medical physicist with the radiation oncologist, had chosen the same parameters of IOERT procedures like energy, applicator (type, size) and using or not bolus. VI) Finally, dose calculation and analysis of 3D maps was carried out. Results: The tuning process of the MC model provides good results, as the maximum value of the root mean square deviation (RMSD) was less than 3% between the MC simulated PDDs and the measured PDDs. The contouring and dose analysis review were easy to conduct for the classical treatment planning system. The radiation oncologist had many tools for dose analysis such as DVH and color wash for all the slides. Summation of the 3D dose of IOERT with other radiotherapy plans is possible and helpful for total dose estimation. Archiving and documentation is as good as treatment planning system (TPS). Conclusions: The method displayed in this paper provides a step forward for IOERT Dosimetry and allows to obtain accurate dosimetry of treated volumes.
引用
收藏
页码:207 / 214
页数:8
相关论文
共 50 条
  • [21] Commissioning a CT-compatible LDR tandem and ovoid applicator using Monte Carlo calculation and 3D dosimetry
    Adamson, Justus
    Newton, Joseph
    Yang, Yun
    Steffey, Beverly
    Cai, Jing
    Adamovics, John
    Oldham, Mark
    Chino, Junzo
    Craciunescu, Oana
    MEDICAL PHYSICS, 2012, 39 (07) : 4515 - 4523
  • [22] Monte Carlo Generators for Studies of the 3D Structure of the Nucleon
    Avakian, Harut
    4TH INTERNATIONAL WORKSHOP ON TRANSVERSE POLARISATION PHENOMENA IN HARD PROCESSES (TRANSVERSITY 2014), 2015, 85
  • [23] Application of a linear interpolation algorithm in radiation therapy dosimetry for 3D dose point acquisition
    Guo, Yixiao
    Li, Bo
    Li, Yazhou
    Du, Wen
    Feng, Weigui
    Feng, Shifang
    Miao, Guoying
    SCIENTIFIC REPORTS, 2023, 13 (01):
  • [24] A novel approach in electron beam radiation therapy of lips carcinoma: A Monte Carlo study
    Shokrani, Parvaneh
    Baradaran-Ghahfarokhi, Milad
    Zadeh, Maryam Khorami
    MEDICAL PHYSICS, 2013, 40 (04)
  • [25] Evaluation of a 3D diamond detector for medical radiation dosimetry
    Kanxheri, K.
    Servoli, L.
    Oh, A.
    Sanchez, F. Munoz
    Forcolin, G. T.
    Murphy, S. A.
    Aitkenhead, A.
    Moore, C. J.
    Morozzi, A.
    Passeri, D.
    Bellini, M.
    Corsi, C.
    Lagomarsino, S.
    Sciortino, S.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [26] 3D dosimetry of High Intensity Therapeutic Electron Beams
    Lamanna, E.
    Fiorillo, A. S.
    Trapasso, A.
    Vena, R.
    Berdondini, A.
    Bettuzzi, M.
    Brancaccio, R.
    Casali, F.
    Morigi, M. P.
    Brancaccio, R.
    Casali, F.
    Morigi, M. P.
    Bilokon, H.
    Barca, G.
    Castrovillari, F.
    Slaka, Y. F. T.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 1033 - +
  • [27] Linear Boltzmann equation solver for voxel-level dosimetry in radiopharmaceutical therapy: Comparison with Monte Carlo and kernel convolution
    Kayal, Gunjan
    Van, Benjamin
    Andl, George
    Tu, Cheng
    Wareing, Todd
    Wilderman, Scott
    Mikell, Justin
    Dewaraja, Yuni K.
    MEDICAL PHYSICS, 2024, 51 (08) : 5604 - 5617
  • [28] Calculation of electron and isotopes dose point kernels with FLUKA Monte Carlo code for dosimetry in nuclear medicine therapy
    Botta, F.
    Mairani, A.
    Battistoni, G.
    Cremonesi, M.
    Di Dia, A.
    Fasso, A.
    Ferrari, A.
    Ferrari, M.
    Paganelli, G.
    Pedroli, G.
    Valente, M.
    MEDICAL PHYSICS, 2011, 38 (07) : 3944 - 3954
  • [29] DOSIMETRY OF A SMALL AIR CAVITY FOR CLINICAL ELECTRON BEAMS: A MONTE CARLO STUDY
    Chow, James C. L.
    Grigorov, Grigor N.
    MEDICAL DOSIMETRY, 2010, 35 (02) : 92 - 100
  • [30] Considerations and limitations of fast Monte Carlo electron transport in radiation therapy based on precalculated data
    Jabbari, Keyvan
    Keall, Paul
    Seuntjens, Jan
    MEDICAL PHYSICS, 2009, 36 (02) : 530 - 540