3D Monte Carlo dosimetry of intraoperative electron radiation therapy (IOERT)

被引:11
|
作者
Alhamada, Husein [1 ,2 ]
Simon, Stephane [1 ,2 ]
Philippson, Catherine [2 ]
Vandekerkhove, Christophe [2 ]
Jourani, Younes [2 ]
Pauly, Nicolas [1 ]
VanGestel, Dirk [2 ]
Reynaert, Nick [1 ,2 ]
机构
[1] Univ Libre Bruxelles, Ecole Polytech, Nucl Metrol, Brussels, Belgium
[2] Inst Jules Bordet, Radiotherapy Dept, Brussels, Belgium
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2019年 / 57卷
关键词
DOSE CALCULATIONS; RADIOTHERAPY; IORT; DISTRIBUTIONS; APPLICATOR; PHOTON;
D O I
10.1016/j.ejmp.2018.12.037
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This paper studies the feasibility of using Monte Carlo (MC) for treatment planning of intraoperative electron radiation therapy (IOERT) procedure to get 3D dose by using patient's CT images. Methods: The IOERT treatment planning was performed using the following successive steps: I) The Mobetron 1000 degrees machine was modelled with the EGSnrc MC codes. II) The MC model was validated with measurements of percentage depth doses and profiles for three energies (12, 9, 6) MeV. III) CT images were imported as DICOM files. IV) Contouring of the planning target volume (PTV) and the organs at risk was done by the radiation oncologist. V) The medical physicist with the radiation oncologist, had chosen the same parameters of IOERT procedures like energy, applicator (type, size) and using or not bolus. VI) Finally, dose calculation and analysis of 3D maps was carried out. Results: The tuning process of the MC model provides good results, as the maximum value of the root mean square deviation (RMSD) was less than 3% between the MC simulated PDDs and the measured PDDs. The contouring and dose analysis review were easy to conduct for the classical treatment planning system. The radiation oncologist had many tools for dose analysis such as DVH and color wash for all the slides. Summation of the 3D dose of IOERT with other radiotherapy plans is possible and helpful for total dose estimation. Archiving and documentation is as good as treatment planning system (TPS). Conclusions: The method displayed in this paper provides a step forward for IOERT Dosimetry and allows to obtain accurate dosimetry of treated volumes.
引用
收藏
页码:207 / 214
页数:8
相关论文
共 50 条
  • [1] Monte Carlo dose calculations of shielding disks with different material combinations in intraoperative electron radiation therapy (IOERT)
    Alhamada, H.
    Simon, S.
    Philippson, C.
    Vandekerkhove, C.
    Jourani, Y.
    Pauly, N.
    Van Gestel, D.
    Reynaert, N.
    CANCER RADIOTHERAPIE, 2020, 24 (02): : 128 - 134
  • [2] In vivo dosimetry using Gafchromic films during pelvic intraoperative electron radiation therapy (IOERT)
    Costa, Filipa
    Sarmento, Sandra
    Gomes, Dora
    Magalhaes, Helena
    Arrais, Rosario
    Moreira, Graciete
    Cruz, Maria Fatima
    Silva, Jose Pedro
    Santos, Lucio
    Sousa, Olga
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1063)
  • [3] Development and verification of an electron Monte Carlo engine for applications in intraoperative radiation therapy
    Rank, Luisa
    Lysakovski, Peter
    Major, Gerald
    Ferrari, Alfredo
    Tessonnier, Thomas
    Debus, Juergen
    Mairani, Andrea
    MEDICAL PHYSICS, 2024, 51 (09) : 6348 - 6364
  • [4] Surface scanning for 3D dose calculation in intraoperative electron radiation therapy
    Garcia-Vazquez, Veronica
    Sese-Lucio, Begona
    Calvo, Felipe A.
    Vaquero, Juan J.
    Desco, Manuel
    Pascau, Javier
    RADIATION ONCOLOGY, 2018, 13
  • [5] Intraoperative electron radiation therapy (IOERT) in patients with locally recurrent renal cell carcinoma
    Habl, Gregor
    Uhl, Matthias
    Hensley, Frank
    Pahernik, Sascha
    Debus, Juergen
    Roeder, Falk
    RADIATION ONCOLOGY, 2013, 8
  • [6] Assessment of intraoperative 3D imaging alternatives for IOERT dose estimation
    Garcia-Vazquez, Veronica
    Marinetto, Eugenio
    Guerra, Pedro
    Valdivieso-Casique, Manlio Fabio
    Angel Calva, Felipe
    Alvarado-Vasquez, Eduardo
    Sole, Claudio Vicente
    Vosburgh, Kirby Gannett
    Desco, Manuel
    Pascau, Javier
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2017, 27 (03): : 218 - 231
  • [7] Feasibility assessment of the interactive use of a Monte Carlo algorithm in treatment planning for intraoperative electron radiation therapy
    Guerra, Pedro
    Udias, Jose M.
    Herranz, Elena
    Antonio Santos-Miranda, Juan
    Herraiz, Joaquin L.
    Valdivieso, Manlio F.
    Rodriguez, Raul
    Calama, Juan A.
    Pascau, Javier
    Calvo, Felipe A.
    Illana, Carlos
    Ledesma-Carbayo, Maria J.
    Santos, Andres
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (23) : 7159 - 7179
  • [8] Implementation of pencil beam redefinition algorithm (PBRA) for intraoperative electron radiation therapy (IOERT) treatment planning
    Tavallaie, Mina
    Tabrizi, Sanaz Hariri
    Heidarloo, Nematollah
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 104 : 32 - 42
  • [9] Intraoperative electron radiation therapy (IOERT) in patients with locally recurrent renal cell carcinoma
    Gregor Habl
    Matthias Uhl
    Frank Hensley
    Sascha Pahernik
    Juergen Debus
    Falk Röder
    Radiation Oncology, 8
  • [10] Dosimetric characterization of a mobile accelerator dedicated for intraoperative radiation therapy: Monte Carlo simulations and experimental validation
    Mastella, Edoardo
    Szilagyi, Klarisa E.
    De Guglielmo, Eleonora
    Fabbri, Sara
    Calderoni, Francesca
    Stefanelli, Antonio
    Di Domenico, Giovanni
    Turra, Alessandro
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 104 : 167 - 173