Comparison of Respirable Mass Concentrations Measured by a Personal Dust Monitor and a Personal DataRAM to Gravimetric Measurements

被引:22
作者
Halterman, Andrew [1 ]
Sousan, Sinan [2 ]
Peters, Thomas M. [2 ]
机构
[1] Univ Iowa, Dept Chem & Biochem Engn, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Occupat & Environm Hlth, Iowa City, IA 52242 USA
关键词
density; gravimetric methods; occupational aerosols; PDM3600; PDM3700; pDR-1500; personal DataRAM; Personal Dust Monitor; refractive index;
D O I
10.1093/annweh/wxx083
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
In 2016, the Mine Safety and Health Administration required the use of continuous monitors to measure respirable dust in mines and better protect miner health. The Personal Dust Monitor, PDM3700, has met stringent performance criteria for this purpose. In a laboratory study, respirable mass concentrations measured with the PDM3700 and a photometer (personal DataRam, pDR-1500) were compared to those measured gravimetrically for five aerosols of varying refractive index and density (diesel exhaust fume, welding fume, coal dust, Arizona road dust (ARD), and salt [NaCl] aerosol) at target concentrations of 0.38, 0.75, and 1.5 mg m(-3). For all aerosols except coal dust, strong, near-one-to-one, linear relationships were observed between mass concentrations measured with the PDM3700 and gravimetrically (diesel fume, slope = 0.99, R-2 = 0.99; ARD, slope = 0.98, R-2 = 0.99; and NaCl, slope = 0.95, R-2 = 0.99).The slope deviated substantially from unity for coal dust (slope = 0.55; R-2 = 0.99). Linear relationships were also observed between mass concentrations measured with the pDR-1500 and gravimetrically, but one-to-one behavior was not exhibited (diesel fume, slope = 0.23, R-2 = 0.76; coal dust, slope = 0.54, R-2 = 0.99; ARD, slope = 0.61, R-2 = 0.99; NaCl, slope = 1.14, R-2 = 0.98). Unlike the pDR-1500, mass concentrations measured with the PDM3700 appear independent of refractive index and density, suggesting that it could have applications in a variety of occupational settings.
引用
收藏
页码:62 / 71
页数:10
相关论文
共 20 条
[1]  
American Conference of Governmental Industrial Hygienists (ACGIH), 2017, THRESH LIM VAL BIOL
[2]   Dielectric Properties of Diesel and Gasoline by Terahertz Spectroscopy [J].
Arik, Enis ;
Altan, Hakan ;
Esenturk, Okan .
JOURNAL OF INFRARED MILLIMETER AND TERAHERTZ WAVES, 2014, 35 (09) :759-769
[3]  
Baron Paul., 1998, NIOSH Manual of Analytical Methods
[4]  
Cantrell B.K., 1990, NIOSH PUB, P651
[5]  
Clipper, 2017, DIEL CONST VAL CLIPP
[6]   Occupational health hazards in mining: an overview [J].
Donoghue, AM .
OCCUPATIONAL MEDICINE-OXFORD, 2004, 54 (05) :283-289
[7]  
GLINSMANN PW, 1985, AM IND HYG ASSOC J, V46, P391
[8]  
MSHA, 2016, MAJOR PROVISIONS EFF
[9]  
MSHA, 2014, FED REG
[10]  
Noll J, 2013, Min Eng, V65, P42