A model for integrating passive and low energy airflow components into low rise buildings

被引:26
作者
Alemu, Alemu T. [1 ]
Saman, Wasim [1 ]
Belusko, Martin [1 ]
机构
[1] Univ S Australia, Sch Adv Mfg & Mech Engn, Barbara Hardy Inst, Adelaide, SA 5001, Australia
关键词
Integrated multi-zone ventilation model; Solar chimney; Wind-induced earth-air tunnel; Natural ventilation; Passive cooling; SOLAR CHIMNEY; NATURAL VENTILATION; HEAT-EXCHANGERS; PERFORMANCE; PREDICT;
D O I
10.1016/j.enbuild.2012.02.002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Integrating passive systems such as cross and stack ventilation, a solar chimney, a wind tower or an earth-air tunnel into a building envelope has the potential to significantly reduce the ventilation and air-conditioning demand on buildings. However the application of combination of these features in low rise contemporary buildings is limited. Among the major reasons, is the lack of simple building modelling techniques preventing effective integrated passive systems. Existing coupled multi-zone airflow and thermal modelling software such as COMIS-TRNSYS, CONTAM-TRNSYS or TRNFLOW do not include the passive airflow components which require simultaneous prediction of temperature and airflow rate in the components such as solar chimneys and wind-induced earth-air tunnels. This paper develops an integrated model incorporating these passive airflow components into a coupled multi-zone ventilation and building thermal model. The model is validated against COMIS-TRNSYS software for a lightweight building with large openings. The prediction of each passive airflow component is validated with available published analytical and experimental findings. The solar chimney model is able to predict reverse flow and accurately predicts the air temperature in the chimney. The earth air tunnel (EAT) considers the transient heating up effect of the soil during operation and predicts the outlet air temperature. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:148 / 157
页数:10
相关论文
共 34 条
[1]   Solar chimneys: simulation and experiment [J].
Afonso, C ;
Oliveira, A .
ENERGY AND BUILDINGS, 2000, 32 (01) :71-79
[2]  
ALLARD F., 1998, Natural ventilation in buildings: a design handbook
[3]  
[Anonymous], 8 INT IBPSA C EINDH
[4]  
[Anonymous], 1996, Numerical methods for unconstrained optimization and nonlinear equations
[5]  
[Anonymous], 2001, HDB FUNDAMENTALS
[6]  
[Anonymous], 16 AIVC C PALM SPRIN
[7]   Experimental investigation of new designs of wind towers [J].
Bahadori, M. N. ;
Mazidi, M. ;
Dehghani, A. R. .
RENEWABLE ENERGY, 2008, 33 (10) :2273-2281
[8]   SOLAR CHIMNEY FOR ENHANCED STACK VENTILATION [J].
BANSAL, NK ;
MATHUR, R ;
BHANDARI, MS .
BUILDING AND ENVIRONMENT, 1993, 28 (03) :373-377
[9]   An analytical and numerical study of solar chimney use for room natural ventilation [J].
Bassiouny, Ramadan ;
Koura, Nader S. A. .
ENERGY AND BUILDINGS, 2008, 40 (05) :865-873
[10]   Effect of solar chimney inclination angle on space flow pattern and ventilation rate [J].
Bassiouny, Ramadan ;
Korah, Nader S. A. .
ENERGY AND BUILDINGS, 2009, 41 (02) :190-196