Differentiation Between Normal and Cancerous Cells at the Single Cell Level Using 3-D Electrode Electrical Impedance Spectroscopy

被引:24
作者
Kang, Giseok [1 ]
Yoo, Sung Keun
Kim, Hyoung-Ihl
Lee, Jong-Hyun [1 ,2 ]
机构
[1] Gwangju Inst Sci & Technol GIST, Grad Program Med Syst Engn GMSE, Sch Informat & Mechatron, Kwangju 500712, South Korea
[2] Gwangju Inst Sci & Technol GIST, Dept Nanobio Mat & Elect, Kwangju 500712, South Korea
基金
新加坡国家研究基金会;
关键词
Early-stage human breast cancer cell (MCF-7); microdevice for electrical impedance spectroscopy (mu EIS); microfluidic tunnel; normal human breast cell (MCF-10A); three-dimensional interdigitated electrodes (3-D IDE); LINES;
D O I
10.1109/JSEN.2011.2167227
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A novel microdevice for electrical impedance spectroscopy EIS is presented to differentiate between normal and cancerous cells at the single cell level with a high sensitivity. The device utilizes amicrofluidic tunnel structure, whose height is smaller than the cell diameters, to squeeze the target cells. Thus, the tight contact between the cells and electrodes allows the device to measure the intrinsic electrical properties of the cells with a higher sensitivity than through noncontact methods. Three-dimensional interdigitated electrodes (3-D IDE) are also employed to confine most of the electric field into the cell membrane, which contains the meaningful electrical properties. Consequently, the variance of the measured values could be reduced because the position of target cells is almost the same in every cell assay. The device well distinguishes normal human breast cells (MCF-10A) from early-stage human breast cancer cells (MCF-7) by means of electrical impedances at 500 kHz; the average differences of the real part and phase angle between the target cells are 44.4 Omega and 1.41 degrees, respectively. The proposed device also shows a high repeatability for the deionized (DI) water test conducted before and after each cell assay; the variances of the real part and phase angle of electrical impedance at 500 kHz are as small as 9.07 Omega and 0.27 degrees, respectively.
引用
收藏
页码:1084 / 1089
页数:6
相关论文
共 17 条
  • [1] An JM, 2008, INT CONF NANO MICRO, P965
  • [3] Chromogenic in situ hybridisation (CISH) should be an accepted method in the routine diagnostic evaluation of HER2 status in breast cancer
    Di Palma, S.
    Collins, N.
    Faulkes, C.
    Ping, B.
    Ferns, G.
    Haagsma, B.
    Layer, G.
    Kissin, M. W.
    Cook, M. G.
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 2007, 60 (09) : 1067 - 1068
  • [4] MICROMOTION OF MAMMALIAN-CELLS MEASURED ELECTRICALLY
    GIAEVER, I
    KEESE, CR
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1991, 88 (17) : 7896 - 7900
  • [5] Quantification of the heterogeneity in breast cancer cell lines using whole-cell impedance spectroscopy
    Han, Arum
    Yang, Lily
    Frazier, A. Bruno
    [J]. CLINICAL CANCER RESEARCH, 2007, 13 (01) : 139 - 143
  • [6] Jemal A, 2009, CA-CANCER J CLIN, V59, P225, DOI [10.3322/caac.20006, 10.3322/caac.21387]
  • [7] Impedance Measurement of Normal and Cancerous Human Breast Cells Using a Microfluidic Tunnel
    Kang, Giseok
    Lee, Sung-Kil
    Yoo, Sung Keun
    Yang, Sung
    Lee, Jong-Hyun
    [J]. 2010 IEEE SENSORS, 2010, : 2109 - 2112
  • [8] Biomechanical analysis of cancerous and normal cells based on bulge generation in a microfluidic device
    Kim, Yu Chang
    Park, Sang-Jin
    Park, Je-Kyun
    [J]. ANALYST, 2008, 133 (10) : 1432 - 1439
  • [9] Single cell dielectric spectroscopy
    Morgan, Hywel
    Sun, Tao
    Holmes, David
    Gawad, Shady
    Green, Nicolas G.
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2007, 40 (01) : 61 - 70
  • [10] Glass-based microfluidic device fabricated by parylene wafer-to-wafer bonding for impedance spectroscopy
    Poenar, Daniel P.
    Iliescu, Ciprian
    Carp, Mihaela
    Pang, Ah Ju
    Leck, Kwong Joo
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2007, 139 (1-2) : 162 - 171