A bent Laue-Laue monochromator for a synchrotron-based monochromatic x-ray computed tomography system

被引:0
作者
Ren, BR [1 ]
机构
[1] Brookhaven Natl Lab, Dept Med, Upton, NY 11973 USA
关键词
BIOMEDICAL RADIOGRAPHY; COMPUTERIZED TOMOGRAPHY; LAUE METHOD; MONOCHROMATORS; NSLS; SILICON; SYNCHROTRON RADIATION; X-RAY DIFFRACTION;
D O I
10.1118/1.598466
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A bent Laue–Laue monochromator for wide, fan-shaped synchrotron x-ray beams was designed and constructed for the program Multiple Energy Computed Tomography (MECT) at the National Synchrotron Light Source (NSLS). MECT uses monochromatic x-ray beams from the NSLS's X17B beamline for CT with improved image contrast-to-noise ratio, image quantification, and the efficacy for dual-energy imaging. The new monochromator uses two Czochralski-grown Si〈111〉 crystals, which are 0.7 and 1.4 mm thick, respectively, and are cut with thick ribs on their upper and lower ends. The crystals are bent cylindrically, using 4-rod benders employing two fixed and two movable rods. The bent-crystal method was needed to solve the difficulties we had with the flat Laue–Laue monochromator previously used in MECT; these included: (a) insufficient beam intensity, (b) excessive beam-intensity fluctuations, and (c) instability of the beam's horizontal profile shape. Compared with flat Laue–Laue monochromator, the bent Laue–Laue device tested at 42 keV and 108 keV showed ∼10-fold increase in the beam flux, ∼5-fold improvement of beam-profile stability, ∼10-fold suppression of beam harmonic contamination at the bending radius of 15 m, and a smaller energy bandwidth at certain bending radii. The new monochromator should reduce MECT's image noise and artifacts, bringing its performance close to that of the ideal CT. © 1998, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2483 / 2483
页数:1
相关论文
共 50 条
[31]   Synchrotron-based X-ray tomographic microscopy for visualization of three-dimensional collagen matrices [J].
Pabst, A. M. ;
Wagner, W. ;
Kasaj, A. ;
Gebhardt, S. ;
Ackermann, M. ;
Astolfo, A. ;
Marone, F. ;
Haberthuer, D. ;
Enzmann, F. ;
Konerding, Moritz A. .
CLINICAL ORAL INVESTIGATIONS, 2015, 19 (02) :561-564
[32]   Plastic Deformation of Insb Micro-Pillars: A comparative Study Between Spatially Resolved Laue and Monochromatic X-Ray Micro-Diffraction Maps [J].
Sadat, Tarik ;
Verezhak, Mariana ;
Godard, Pierre ;
Renault, Pierre Olivier ;
Van Petegem, Steven ;
Jacques, Vincent ;
Diaz, Ana ;
Grolimund, Daniel ;
Thilly, Ludovic .
RESIDUAL STRESSES 2018, ECRS-10, 2018, 6 :21-26
[33]   Flattening filter for Gaussian-shaped monochromatic X-ray beams: an application to breast computed tomography [J].
Donato, Sandro ;
Arfelli, Fulvia ;
Brombal, Luca ;
Longo, Renata ;
Pinto, Andrea ;
Rigon, Luigi ;
Dreossi, Diego .
JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 :503-506
[34]   Synchrotron-based X-ray tomographic microscopy for visualization of three-dimensional collagen matrices [J].
A. M. Pabst ;
W. Wagner ;
A. Kasaj ;
S. Gebhardt ;
M. Ackermann ;
A. Astolfo ;
F. Marone ;
D. Haberthür ;
F. Enzmann ;
Moritz A. Konerding .
Clinical Oral Investigations, 2015, 19 :561-564
[35]   New types of X-ray computed tomography (CT) with synchrotron radiation: Fluorescent X-ray CT and phase-contrast X-ray CT using interferometer [J].
Takeda, T ;
Momose, A ;
Yu, QW ;
Yuasa, T ;
Dilmanian, FA ;
Akatsuka, T ;
Itai, Y .
CELLULAR AND MOLECULAR BIOLOGY, 2000, 46 (06) :1077-1088
[36]   Minimal detectability of contrast materials in fluorescent x-ray computed tomography using synchrotron radiation [J].
Yu, Q ;
Takeda, T ;
Yuasa, T ;
Hasegawa, Y ;
Zeniya, T ;
Hyodo, K ;
Itai, Y ;
Akatsuka, T .
IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, :230-231
[37]   X-ray computed tomography system using a multipixel photon counter [J].
Sato, Eiichi ;
Matsukiyo, Hiroshi ;
Osawa, Akihiro ;
Enomoto, Toshiyuki ;
Watanabe, Manabu ;
Nagao, Jiro ;
Abderyim, Purkhet ;
Nomiya, Seiichiro ;
Hitomi, Keitaro ;
Ogawa, Akira ;
Sato, Shigehiro .
HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS X, 2008, 7079
[38]   Digital Rock Physics Results from Phase-Contrast Synchrotron-Based X-ray Microtomography [J].
Visconti, Luca ;
Radaelli, Francesco ;
Ortenzi, Andrea ;
Della Torre, Augusto ;
Ierardi, Cristian ;
Di Lillo, Francesca ;
Mancini, Lucia .
SELECTED STUDIES IN GEOPHYSICS, TECTONICS AND PETROLEUM GEOSCIENCES, CAJG-3 2020, 2024, :95-98
[39]   Analyses of the mouthpart kinematics in Periplaneta americana (Blattodea, Blattidae) using synchrotron-based X-ray cineradiography [J].
Schmitt, Christian ;
Rack, Alexander ;
Betz, Oliver .
JOURNAL OF EXPERIMENTAL BIOLOGY, 2014, 217 (17) :3095-3107
[40]   Investigation of chemical composition of belemnite rostra by synchrotron-based X-ray microfluorescence and diffraction and electron microprobe [J].
Florek, M ;
Youn, HS ;
Ro, CU ;
Wierzbowski, H ;
Osán, J ;
Kazimierczak, W ;
Kuczumow, A .
JOURNAL OF ALLOYS AND COMPOUNDS, 2004, 362 (1-2) :99-106