Quantitative comparison of the bolus and steady-state methods for measurement of cerebral perfusion and oxygen metabolism:: Positron emission tomography study using 15O-gas and water

被引:57
作者
Okazawa, H
Yamauchi, H
Sugimoto, K
Takahashi, M
Toyoda, H
Kishibe, Y
Shio, H
机构
[1] Shiga Med Ctr, Res Inst, PET Unit, Moriyama, Shiga 5248524, Japan
[2] Kyoto Univ, Grad Sch Med, Dept Nucl Med & Diagnost Imaging, Kyoto, Japan
关键词
cerebral metabolic rate of oxygen; cerebral blood volume; positron emission tomography; weighted integral method; steady-state method;
D O I
10.1097/00004647-200107000-00004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate a new simplified bolus method for measurement of cerebral perfusion and metabolism, the parametric images with that method were compared with those obtained from the conventional steady-state method with O-15-gas. The new method also provided images of arterial blood volume (V,), which is a different parameter from cerebral blood volume (CBV) obtained using a (CO)-O-15 technique. Seven healthy volunteers and 10 patients with occlusive cerebrovascular diseases underwent positron emission tomography (PET) scans with both methods. Three-weighted integration was applied to calculate regional cerebral blood flow (rCBF) and regional cerebral metabolic rate of oxygen (rCMRO(2)) in the bolus method. Global and regional CBF and CMRO2 in volunteers were compared between the two methods and used as control data. Regional values in patients also were evaluated to observe differences between the bilateral hemispheres. Both rCBF and rCMRO(2) were linearly well correlated between the two methods, although global difference in CMRO2 was significant. The difference in each parametric image except for V, was significant between the bilateral hemispheres in patients. The bolus method can simplify oxygen metabolism studies and yield parametric images comparable with those with the steady state method, and can allow for evaluation of V, simultaneously. Increase in CBV without a change in V, suggested the increase might mainly be caused by venous dilatation in the ischemic regions.
引用
收藏
页码:793 / 803
页数:11
相关论文
共 35 条
[1]   STRATEGY FOR THE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW USING SHORT-LIVED TRACERS AND EMISSION TOMOGRAPHY [J].
ALPERT, NM ;
ERIKSSON, L ;
CHANG, JY ;
BERGSTROM, M ;
LITTON, JE ;
CORREIA, JA ;
BOHM, C ;
ACKERMAN, RH ;
TAVERAS, JM .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1984, 4 (01) :28-34
[2]   REVERSAL OF FOCAL MISERY-PERFUSION SYNDROME BY EXTRA-INTRACRANIAL ARTERIAL BYPASS IN HEMODYNAMIC CEREBRAL-ISCHEMIA - A CASE-STUDY WITH O-15 POSITRON EMISSION TOMOGRAPHY [J].
BARON, JC ;
BOUSSER, MG ;
REY, A ;
GUILLARD, A ;
COMAR, D ;
CASTAIGNE, P .
STROKE, 1981, 12 (04) :454-459
[3]   AUTOMATIC 3D INTERSUBJECT REGISTRATION OF MR VOLUMETRIC DATA IN STANDARDIZED TALAIRACH SPACE [J].
COLLINS, DL ;
NEELIN, P ;
PETERS, TM ;
EVANS, AC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (02) :192-205
[4]  
DEGRADO TR, 1994, J NUCL MED, V35, P1398
[5]  
Dhawan Vijay, 1998, Clin Positron Imaging, V1, P135, DOI 10.1016/S1095-0397(98)00009-0
[6]   STIMULUS RATE DEPENDENCE OF REGIONAL CEREBRAL BLOOD-FLOW IN HUMAN STRIATE CORTEX, DEMONSTRATED BY POSITRON EMISSION TOMOGRAPHY [J].
FOX, PT ;
RAICHLE, ME .
JOURNAL OF NEUROPHYSIOLOGY, 1984, 51 (05) :1109-1120
[7]   QUANTITATIVE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW AND OXYGEN-METABOLISM IN MAN USING O-15 AND POSITRON EMISSION TOMOGRAPHY - THEORY, PROCEDURE, AND NORMAL VALUES [J].
FRACKOWIAK, RSJ ;
LENZI, GL ;
JONES, T ;
HEATHER, JD .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1980, 4 (06) :727-736
[8]   THE RELATIONSHIP BETWEEN GLOBAL AND LOCAL CHANGES IN PET SCANS [J].
FRISTON, KJ ;
FRITH, CD ;
LIDDLE, PF ;
DOLAN, RJ ;
LAMMERTSMA, AA ;
FRACKOWIAK, RSJ .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1990, 10 (04) :458-466
[9]   COMPARING FUNCTIONAL (PET) IMAGES - THE ASSESSMENT OF SIGNIFICANT CHANGE [J].
FRISTON, KJ ;
FRITH, CD ;
LIDDLE, PF ;
FRACKOWIAK, RSJ .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1991, 11 (04) :690-699
[10]  
GIBBS JM, 1984, LANCET, V1, P310