Assessment of mitral regurgitant jets by three-dimensional color Doppler

被引:19
作者
De Simone, R
Glombitza, G
Vahl, CF
Albers, J
Meinzer, HP
Hagl, S
机构
[1] Univ Heidelberg, Abt Herzchirurg, Dept Cardiac Surg, D-69120 Heidelberg, Germany
[2] Deutsch Krebsforschungszentrum, Dept Med & Biol Informat, D-6900 Heidelberg, Germany
关键词
D O I
10.1016/S0003-4975(98)01096-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Color Doppler echocardiography is a standard technique for assessing mitral regurgitation before and after mitral valvuloplasty. Mitral valve prolapse produces complex eccentric jet flows that cannot be visualized and measured by two-dimensional color Doppler echocardiography. The aim of this study was to evaluate the clinical impact of three-dimensional color Doppler echocardiography, a new technique developed at our institution for assessing mitral regurgitation. Methods. Forty-five patients with mitral regurgitation underwent intraoperative transesophageal echocardiography and three-dimensional Doppler data acquisition The grade of mitral regurgitation was assessed by angiography. The jet areas were calculated by planimetry from conventional color Doppler; the jet volumes were obtained by three-dimensional Doppler data, Results. New patterns of mitral regurgitant flows were recognized according to the origin, direction, and spatial spreading into the left atrium. Conventional jet areas failed to separate the groups of patients with different degrees of regurgitation, whereas the jet volumes were able to divide patients with different regurgitation grades. No significant correlation was found between jet area and angiographic grading (r = 0.63, p = NS). Jet volumes were significantly correlated to angiography (r = 0.89, p < 0.001). Conclusions. Three-dimensional color Doppler echocardiography revealed new patterns of regurgitant now and allowed a more accurate semiquantitative assessment of complex asymmetrical regurgitant jets. (C) 1999 by The Society of Thoracic Surgeons.
引用
收藏
页码:494 / 499
页数:6
相关论文
共 28 条
[1]  
Belohlavek M, 1994, J Am Soc Echocardiogr, V7, P553
[2]  
Bohs L N, 1995, J Am Soc Echocardiogr, V8, P915, DOI 10.1016/S0894-7317(05)80016-1
[3]   QUANTIFYING VALVULAR REGURGITATION - LIMITATIONS AND INHERENT ASSUMPTIONS OF DOPPLER TECHNIQUES [J].
BOLGER, AF ;
EIGLER, NL ;
MAURER, G .
CIRCULATION, 1988, 78 (05) :1316-1318
[4]  
Buck T, 1996, J Am Soc Echocardiogr, V9, P488, DOI 10.1016/S0894-7317(96)90120-0
[5]   IMPACT OF IMPINGING WALL JET ON COLOR DOPPLER QUANTIFICATION OF MITRAL REGURGITATION [J].
CHEN, CG ;
THOMAS, JD ;
ANCONINA, J ;
HARRIGAN, P ;
MUELLER, L ;
PICARD, MH ;
LEVINE, RA ;
WEYMAN, AE .
CIRCULATION, 1991, 84 (02) :712-720
[6]   LIMITATIONS OF QUALITATIVE ANGIOGRAPHIC GRADING IN AORTIC OR MITRAL REGURGITATION [J].
CROFT, CH ;
LIPSCOMB, K ;
MATHIS, K ;
FIRTH, BG ;
NICOD, P ;
TILTON, G ;
WINNIFORD, MD ;
HILLIS, LD .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (11) :1593-1598
[7]   DYNAMIC 3-DIMENSIONAL ECHOCARDIOGRAPHIC ASSESSMENT OF INTRACARDIAC BLOOD-FLOW JETS [J].
DELABAYS, A ;
SUGENG, L ;
PANDIAN, NG ;
HSU, TL ;
HO, SJ ;
CHEN, CH ;
MARX, G ;
SCHWARTZ, SL ;
CAO, QL .
AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (14) :1053-1058
[8]   Atrioventricular valve insufficiency and atrial geometry after orthotopic heart transplantation [J].
DeSimone, R ;
Lange, R ;
Sack, FU ;
Mehmanesh, H ;
Hagl, S .
ANNALS OF THORACIC SURGERY, 1995, 60 (06) :1686-1693
[9]   INTRAOPERATIVE TRANSESOPHAGEAL ECHOCARDIOGRAPHY FOR THE EVALUATION OF MITRAL, AORTIC AND TRICUSPID-VALVE REPAIR - A TOOL TO OPTIMIZE SURGICAL OUTCOME [J].
DESIMONE, R ;
LANGE, R ;
SAGGAU, W ;
GAMS, E ;
TANZEEM, A ;
HAGL, S .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1992, 6 (12) :665-673
[10]   ADJUSTABLE TRICUSPID-VALVE ANNULOPLASTY ASSISTED BY INTRAOPERATIVE TRANSESOPHAGEAL COLOR DOPPLER ECHOCARDIOGRAPHY [J].
DESIMONE, R ;
LANGE, R ;
TANZEEM, A ;
GAMS, E ;
HAGL, S .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (11) :926-931