Percutaneous closure of patent foramen ovale

被引:20
作者
Bijl, JM
Ruygrok, PN
Hornung, TS
Wilson, NJ
West, T
机构
[1] Auckland City Hosp, Green Lane Cardiovasc Serv, Auckland 1001, New Zealand
[2] Auckland City Hosp, Paediat & Congenital Cardiol Serv, Auckland 1001, New Zealand
关键词
patent foramen ovale; transcatheter closure; Amplatzer device;
D O I
10.1111/j.1445-5994.2005.00948.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: To review the safety and efficacy of percutaneous closure of patent foramen ovale (PFO) in symptomatic patients without the use of general anaesthesia or echocardiographic guidance. Method: All patients accepted for percutaneous PFO closure by our service from August 2002 to August 2004 were included. Patient demographics and clinical information were obtained from clinical records and by telephone interview. Follow-up outcomes recorded were recurrence of systemic thromboembolism, residual shunt, and change in pattern of migraines. Results: Forty consecutive adult patients, of whom 19 (48%) had an atrial septal aneurysm (ASA), underwent PFO closure using the Amplatzer occluder device with fluoroscopic guidance alone. Their mean age was 45 +/- 10 years (range 23-63 years) and 24 (60%) were male. The indications for closure were ischaemic stroke (n=26), transient ischaemic attack (TIA) (n=8), both stroke and TIA (n=2), refractory hypoxia (n=2), platypnoea-orthodeoxia (n=1) and severe migraine with seizures (n=1). Twenty patients suffered a single neurological event and 16 suffered > 1 event, including six with only radiographic evidence of > 1 event. Mean procedure time was 17.7 +/- 9.6 min and fluoroscopy time was 6.7 +/- 7.3 min. Implanted device sizes were 18 mm (n=1), 25 mm (n=37) and 35 mm (n=2). In 33 patients, the procedure was performed as a day-case. No complications were encountered. No further neurological events occurred in 39 patients at a mean follow-up time of 11 +/- 7 months (3-25 months) nor was a significant shunt detected in the 34 who underwent follow-up echocardiography. Conclusions: Percutaneous closure of PFO with or without ASA, under local anaesthesia and without echocardiographic guidance, is a safe and effective procedure which can be performed as a day-case. This has now become our standard clinical practice.
引用
收藏
页码:706 / 710
页数:5
相关论文
共 27 条
  • [1] Erosion of amplatzer septal occluder device after closure of secundum atrial septal defects: Review of registry of complications and recommendations to minimize future risk
    Amin, Z
    Hijazi, ZM
    Bass, JL
    Cheatham, JP
    Hellenbrand, WE
    Kleinman, CS
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 63 (04) : 496 - 502
  • [2] Does transcatheter closure of patent foramen ovale really "Shut the door?" A prospective study with tanscranial Doppler
    Anzola, GP
    Morandi, E
    Casilli, F
    Onorato, E
    [J]. STROKE, 2004, 35 (09) : 2140 - 2144
  • [3] Stroke recurrence in patients with patent foramen ovale: The Lausanne Study
    Bogousslavsky, J
    Garazi, S
    Jeanrenaud, X
    Aebischer, N
    VanMelle, G
    [J]. NEUROLOGY, 1996, 46 (05) : 1301 - 1305
  • [4] Transcatheter closure of patent foramen ovale (PFO) in patients with paradoxical embolism - Periprocedural safety and mid-term follow-up results of three different device occluder systems
    Braun, M
    Gliech, V
    Boscheri, A
    Schoen, S
    Gahn, G
    Reichmann, H
    Haass, M
    Schraeder, R
    Strasser, RH
    [J]. EUROPEAN HEART JOURNAL, 2004, 25 (05) : 424 - 430
  • [5] Transcatheter closure of interatrial communications for secondary prevention of paradoxical embolism - Single-center experience
    Bruch, L
    Parsi, A
    Grad, MO
    Rux, S
    Burmeister, T
    Krebs, H
    Kleber, FX
    [J]. CIRCULATION, 2002, 105 (24) : 2845 - 2848
  • [6] ATRIAL SEPTAL ANEURYSM AND PATENT FORAMEN OVALE AS RISK-FACTORS FOR CRYPTOGENIC STROKE IN PATIENTS LESS-THAN 55 YEARS OF AGE - A STUDY USING TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    CABANES, L
    MAS, JL
    COHEN, A
    AMARENCO, P
    CABANES, PA
    OUBARY, P
    CHEDRU, F
    GUERIN, F
    BOUSSER, MG
    DERECONDO, J
    [J]. STROKE, 1993, 24 (12) : 1865 - 1873
  • [7] Morphological and functional characteristics of patent foramen ovale and their embolic implications
    De Castro, S
    Cartoni, D
    Fiorelli, M
    Rasura, M
    Anzini, A
    Zanette, EM
    Beccia, M
    Colonnese, C
    Fedele, F
    Fieschi, C
    Pandian, NG
    [J]. STROKE, 2000, 31 (10) : 2407 - 2413
  • [8] PATENT FORAMEN OVALE AS A RISK FACTOR FOR CRYPTOGENIC STROKE
    DITULLIO, M
    SACCO, RL
    GOPAL, A
    MOHR, JP
    HOMMA, S
    [J]. ANNALS OF INTERNAL MEDICINE, 1992, 117 (06) : 461 - 465
  • [9] Cardiac perforation after device closure of atrial septal defects with the Amplatzer septal occluder
    Divekar, A
    Gaamangwe, T
    Shaikh, N
    Raabe, M
    Ducas, J
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (08) : 1213 - 1218
  • [10] THE INCIDENCE OF PATENT FORAMEN OVALE IN 1,000 CONSECUTIVE PATIENTS - A CONTRAST TRANSESOPHAGEAL ECHOCARDIOGRAPHY STUDY
    FISHER, DC
    FISHER, EA
    BUDD, JH
    ROSEN, SE
    GOLDMAN, ME
    [J]. CHEST, 1995, 107 (06) : 1504 - 1509