Design of a combined X-ray fluorescence Computed Tomography (CT) and photon-counting CT table-top imaging system

被引:7
作者
Dunning, C. A. S. [1 ]
Bazalova-Carter, M. [1 ]
机构
[1] Univ Victoria, Dept Phys & Astron, 3800 Finnerty Rd, Victoria, BC, Canada
基金
加拿大创新基金会; 加拿大自然科学与工程研究理事会;
关键词
X-ray fluorescence (XRF) systems; Computerized Tomography (CT) and Computed Radiography (CR); Multi-modality systems; CONTRAST AGENTS; XFCT; FEASIBILITY; SENSITIVITY; GADOLINIUM;
D O I
10.1088/1748-0221/15/06/P06031
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper demonstrates the capability of a table-top x-ray imaging system to simultaneously image a small animal phantom loaded with Gd and Au contrast agents with photon-counting computed tomography (PCCT) and x-ray fluorescence CT (XFCT). Our table-top system consisted of a diagnostic x-ray tube, translation and rotation stages, a 330 tm-pitch cadmium zinc telluride (CZT) photon-counting detector with six energy bins, and two CdTe spectrometers which detected fluorescent x-rays in 0.5 keV bins. The energy bin thresholds on the CZT detector matched the contrast agent K-edge energies, enabling K-edge PCCT. A 3 cm-diameter phantom containing vials of 1% and 5% Gd and Au solutions by weight, including a mixed 1% Gd/Au vial, was scanned with 0.5 mm Cu-filtered 120 kVp x-rays at 2 mA. A pencil beam geometry was used with 33 translation and 30 rotation steps to form XFCT and K-edge PCCT images. A cone beam geometry with 180 rotation steps was used to form higher-resolution K-edge PCCT images. Three mice were each injected post-mortem with 0.2 mL of 5% Gd, Au, or mixed Gd/Au solutions in the upper torso and imaged similarly to the phantom. The lowest detectable concentration based on the Rose criterion for Gd and Au phantom data was 0.75% and 3.0% for XFCT, 0.81% and 0.82% for pencil beam K-edge PCCT, and 0.79% and 1.5% for cone beam K-edge PCCT. However, cone beam K-edge PCCT images have a much higher spatial resolution than the pencil beam images. The mixed 1% Gd/Au signal was diminished in the K-edge PCCT phantom images. Preliminary mouse images of Gd and Au among the imaging techniques were similar in image quality as the phantom images. This is the first demonstration of simultaneously-acquired XFCT and PCCT of both Gd and Au in a phantom on a table-top imaging system. On our system, cone beam PCCT is best for imaging Gd, pencil beam PCCT is best for imaging Au, and pencil beam XFCT is better suited toward resolving mixtures of contrast agents.
引用
收藏
页数:22
相关论文
共 45 条
[1]   Optimized Detector Angular Configuration Increases the Sensitivity of X-ray Fluorescence Computed Tomography (XFCT) [J].
Ahmad, Moiz ;
Bazalova-Carter, Magdalena ;
Fahrig, Rebecca ;
Xing, Lei .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (05) :1140-1147
[2]   Order of Magnitude Sensitivity Increase in X-ray Fluorescence Computed Tomography (XFCT) Imaging With an Optimized Spectro-Spatial Detector Configuration: Theory and Simulation [J].
Ahmad, Moiz ;
Bazalova, Magdalena ;
Xiang, Liangzhong ;
Xing, Lei .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (05) :1119-1128
[3]   Gadolinium chelate coated gold nanoparticles as contrast agents for both X-ray computed tomography and magnetic resonance imaging [J].
Alric, Christophe ;
Taleb, Jacqueline ;
Le Duc, Geraldine ;
Mandon, Celine ;
Billotey, Claire ;
Le Meur-Herland, Alice ;
Brochard, Thierry ;
Vocanson, Francis ;
Janier, Marc ;
Perriat, Pascal ;
Roux, Stephane ;
Tillement, Olivier .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (18) :5908-5915
[4]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[5]   Investigation of X-ray Fluorescence Computed Tomography (XFCT) and K-Edge Imaging [J].
Bazalova, Magdalena ;
Kuang, Yu ;
Pratx, Guillem ;
Xing, Lei .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (08) :1620-1627
[6]   Hybrid Spectral Micro-CT: System Design, Implementation, and Preliminary Results [J].
Bennett, James R. ;
Opie, Alex M. T. ;
Xu, Qiong ;
Yu, Hengyong ;
Walsh, Michael ;
Butler, Anthony ;
Butler, Phillip ;
Cao, Guohua ;
Mohs, Aaron ;
Wang, Ge .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (02) :246-253
[7]  
Boone John M, 2004, Mol Imaging, V3, P149, DOI 10.1162/1535350042380326
[8]  
Breitkreutz D.Y., 2020, EXPT DEMONSTRA UNPUB
[9]   Quantification of multiple mixed contrast and tissue compositions using photon-counting spectral computed tomography [J].
Curtis, Tyler E. ;
Roeder, Ryan K. .
JOURNAL OF MEDICAL IMAGING, 2019, 6 (01)
[10]   Investigation of transmission computed tomography (CT) image quality and x-ray dose achievable from an experimental dual-mode benchtop x-ray fluorescence CT and transmission CT system [J].
Deng, Luzhen ;
Yasar, Selcuk ;
Ahmed, Md Foiez ;
Jayarathna, Sandun ;
Feng, Peng ;
Wei, Biao ;
Vedantham, Srinivasan ;
Karellas, Andrew ;
Cho, Sang Hyun .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (03) :431-442