Design of a combined X-ray fluorescence Computed Tomography (CT) and photon-counting CT table-top imaging system

被引:7
|
作者
Dunning, C. A. S. [1 ]
Bazalova-Carter, M. [1 ]
机构
[1] Univ Victoria, Dept Phys & Astron, 3800 Finnerty Rd, Victoria, BC, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大创新基金会;
关键词
X-ray fluorescence (XRF) systems; Computerized Tomography (CT) and Computed Radiography (CR); Multi-modality systems; CONTRAST AGENTS; XFCT; FEASIBILITY; SENSITIVITY; GADOLINIUM;
D O I
10.1088/1748-0221/15/06/P06031
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper demonstrates the capability of a table-top x-ray imaging system to simultaneously image a small animal phantom loaded with Gd and Au contrast agents with photon-counting computed tomography (PCCT) and x-ray fluorescence CT (XFCT). Our table-top system consisted of a diagnostic x-ray tube, translation and rotation stages, a 330 tm-pitch cadmium zinc telluride (CZT) photon-counting detector with six energy bins, and two CdTe spectrometers which detected fluorescent x-rays in 0.5 keV bins. The energy bin thresholds on the CZT detector matched the contrast agent K-edge energies, enabling K-edge PCCT. A 3 cm-diameter phantom containing vials of 1% and 5% Gd and Au solutions by weight, including a mixed 1% Gd/Au vial, was scanned with 0.5 mm Cu-filtered 120 kVp x-rays at 2 mA. A pencil beam geometry was used with 33 translation and 30 rotation steps to form XFCT and K-edge PCCT images. A cone beam geometry with 180 rotation steps was used to form higher-resolution K-edge PCCT images. Three mice were each injected post-mortem with 0.2 mL of 5% Gd, Au, or mixed Gd/Au solutions in the upper torso and imaged similarly to the phantom. The lowest detectable concentration based on the Rose criterion for Gd and Au phantom data was 0.75% and 3.0% for XFCT, 0.81% and 0.82% for pencil beam K-edge PCCT, and 0.79% and 1.5% for cone beam K-edge PCCT. However, cone beam K-edge PCCT images have a much higher spatial resolution than the pencil beam images. The mixed 1% Gd/Au signal was diminished in the K-edge PCCT phantom images. Preliminary mouse images of Gd and Au among the imaging techniques were similar in image quality as the phantom images. This is the first demonstration of simultaneously-acquired XFCT and PCCT of both Gd and Au in a phantom on a table-top imaging system. On our system, cone beam PCCT is best for imaging Gd, pencil beam PCCT is best for imaging Au, and pencil beam XFCT is better suited toward resolving mixtures of contrast agents.
引用
收藏
页数:22
相关论文
共 42 条
  • [1] Optimization of a table-top x-ray fluorescence computed tomography (XFCT) system
    Dunning, C. A. S.
    Bazalova-Carter, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (23)
  • [2] Photon-counting x-ray detectors for CT
    Danielsson, Mats
    Persson, Mats
    Sjolin, Martin
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (03)
  • [3] Simultaneous X-ray fluorescence and K-edge CT imaging with photon-counting detectors
    Li, Liang
    Li, Ruizhe
    Zhang, Siyuan
    Chen, Zhiqiang
    DEVELOPMENTS IN X-RAY TOMOGRAPHY X, 2016, 9967
  • [4] Energy-Resolved Photon-Counting X-Ray Imaging Arrays for Clinical K-Edge CT
    Barber, William C.
    Nygard, Einar
    Wessel, Jan C.
    Malakhov, Nail
    Wawrzyniak, Gregor
    Hartsough, Neal E.
    Gandhi, Thulasi
    Iwanczyk, Jan S.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4441 - 4446
  • [5] Photon-counting computed tomography of lanthanide contrast agents with a high-flux 330-μrn-pitch cadmium zinc telluride detector in a table-top system
    Dunning, Chelsea A. S.
    O'Connell, Jericho
    Robinson, Spencer M.
    Murphy, Kevin J.
    Frencken, Adriaan L.
    van Veggel, Frank C. J. M.
    Iniewski, Kris
    Bazalova-Carter, Magdalena
    JOURNAL OF MEDICAL IMAGING, 2020, 7 (03)
  • [6] Full-field fan-beam x-ray fluorescence computed tomography with a conventional x-ray tube and photon-counting detectors for fast nanoparticle bioimaging
    Li, Liang
    Zhang, Siyuan
    Li, Ruizhe
    Chen, Zhiqiang
    OPTICAL ENGINEERING, 2017, 56 (04)
  • [7] Photon-counting computed tomography of lanthanide contrast agents with a high-flux 330- μ m-pitch cadmium zinc telluride detector in a table-top system
    Dunning C.A.S.
    O'Connell J.
    Robinson S.M.
    Murphy K.J.
    Frencken A.L.
    Van Veggel F.C.J.M.
    Iniewski K.
    Bazalova-Carter M.
    Dunning, Chelsea A. S. (cdunning@uvic.ca), 1600, SPIE (07):
  • [8] Simulation Research of Potential Contrast Agents for X-Ray Fluorescence CT with Photon Counting Detectors
    Yan, Luo
    Feng Peng
    Zhao Ruge
    Zhang Yi
    An Kang
    He Peng
    Yan Shenghao
    Zhao Xiansheng
    FRONTIERS IN PHYSICS, 2021, 9
  • [9] Investigation of transmission computed tomography (CT) image quality and x-ray dose achievable from an experimental dual-mode benchtop x-ray fluorescence CT and transmission CT system
    Deng, Luzhen
    Yasar, Selcuk
    Ahmed, Md Foiez
    Jayarathna, Sandun
    Feng, Peng
    Wei, Biao
    Vedantham, Srinivasan
    Karellas, Andrew
    Cho, Sang Hyun
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (03) : 431 - 442
  • [10] Noise in energy-discriminating photon-counting x-ray imaging detectors
    Tanguay, Jesse
    Kim, Ho Kyung
    Cunningham, Ian A.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622