The locus of fixation and the foveal cone mosaic

被引:137
作者
Putnam, NM
Hofer, HJ
Doble, N
Chen, L
Carroll, J
Williams, DR [1 ]
机构
[1] Univ Rochester, Ctr Visual Sci, Rochester, NY 14627 USA
[2] Univ Rochester, Inst Opt, Rochester, NY 14627 USA
关键词
physiological optics; eye movements; fixation; adaptive optics; cone density; fovea;
D O I
10.1167/5.7.3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
High-resolution retinal imaging with adaptive optics was used to record the position of a light stimulus on the cone mosaic with an error at least five times smaller than the diameter of the smallest foveal cones. We discuss the factors that limit the accuracy with which absolute retinal position can be determined. In five subjects, the standard deviation of fixation positions measured in discrete trials ranged from 2.1 to 6.3 arcmin, with an average of 3.4 arcmin ( about 17 mu m), in agreement with previous studies ( R. W. Ditchburn, 1973; R. M. Steinman, G. M. Haddad, A. A. Skavenski, & D. Wyman, 1973). The center of fixation, based on the mean retinal position for each of three subjects, was displaced from the location of highest foveal cone density by an average of about 10 arcmin ( about 50 mu m), indicating that cone density alone does not drive the location on the retina selected for fixation. This method can be used in psychophysical studies or medical applications requiring submicron registration of stimuli with respect to the retina or in delivering light to retinal features as small as single cells.
引用
收藏
页码:632 / 639
页数:8
相关论文
共 45 条
[1]  
[Anonymous], VISUAL PSYCHOPHYSICS
[2]   SIMULTANEOUS MEASUREMENT OF 2-POINT-SPREAD FUNCTIONS AT DIFFERENT LOCATIONS ACROSS THE HUMAN FOVEA [J].
ARTAL, P ;
NAVARRO, R .
APPLIED OPTICS, 1992, 31 (19) :3646-3656
[3]   EYE MOVEMENTS DURING FIXATION [J].
BARLOW, HB .
JOURNAL OF PHYSIOLOGY-LONDON, 1952, 116 (03) :290-306
[4]   A FUNCTIONAL TEST OF FOVEAL FIXATION BASED UPON DIFFERENTIAL CONE DIRECTIONAL SENSITIVITY [J].
BEDELL, HE .
VISION RESEARCH, 1980, 20 (06) :557-560
[5]  
CARPENTER RHS, 1991, VISION VISUAL FUNCTI, V8, P1
[6]   THE RELATIVE NUMBERS OF LONG-WAVELENGTH-SENSITIVE TO MIDDLE-WAVELENGTH-SENSITIVE CONES IN THE HUMAN FOVEA CENTRALIS [J].
CICERONE, CM ;
NERGER, JL .
VISION RESEARCH, 1989, 29 (01) :115-128
[7]  
CLEMMESEN V, 1944, ACTA PHYSIOL SCA S27, V9, P115
[8]   NEW TECHNIQUE FOR THE MEASUREMENT OF SMALL EYE MOVEMENTS [J].
CORNSWEET, TN .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1958, 48 (11) :808-811
[9]   ACCURATE 2-DIMENSIONAL EYE TRACKER USING FIRST AND FOURTH PURKINJE IMAGES [J].
CORNSWEET, TN ;
CRANE, HD .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1973, 63 (08) :921-928
[10]   ACCURATE 3-DIMENSIONAL EYETRACKER [J].
CRANE, HD ;
STEELE, CM .
APPLIED OPTICS, 1978, 17 (05) :691-705