Metal artefact reduction for patients with metallic dental fillings in helical neck computed tomography: comparison of adaptive iterative dose reduction 3D (AIDR 3D), forward-projected model-based iterative reconstruction solution (FIRST) and AIDR 3D with single-energy metal artefact reduction (SEMAR)

被引:32
作者
Yasaka, Koichiro [1 ]
Kamiya, Kouhei [1 ]
Irie, Ryusuke [1 ]
Maeda, Eriko [1 ]
Sato, Jiro [1 ]
Ohtomo, Kuni [1 ]
机构
[1] Univ Tokyo, Grad Sch Med, Dept Radiol, Tokyo, Japan
关键词
neck; CT; pharynx; metal; artefact; SQUAMOUS-CELL-CARCINOMA; ORAL-CAVITY; CT SCANS; ALGORITHM; DIAGNOSIS; HARDWARE; MRI;
D O I
10.1259/dmfr.20160114
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To compare the differences in metal artefact degree and the depiction of structures in helical neck CT, in patients with metallic dental fillings, among adaptive iterative dose reduction three dimensional (AIDR 3D), forward-projected model-based iterative reconstruction solution (FIRST) and AIDR 3D with single-energy metal artefact reduction (SEMAR-A). Methods: In this retrospective clinical study, 22 patients (males, 13; females, 9; mean age, 64.6 +/- 12.6 years) with metallic dental fillings who underwent contrast-enhanced helical CT involving the oropharyngeal region were included. Neck axial images were reconstructed with AIDR 3D, FIRST and SEMAR-A. Metal artefact degree and depiction of structures (the apex and root of the tongue, parapharyngeal space, superior portion of the internal jugular chain and parotid gland) were evaluated on a four-point scale by two radiologists. Placing regions of interest, standard deviations of the oral cavity and nuchal muscle (at the slice where no metal exists) were measured and metal artefact indices were calculated (the square root of the difference of the squares of them). Results: In SEMAR-A, metal artefact was significantly reduced and depictions of all structures were significantly improved compared with those in FIRST and AIDR 3D (p <= 0.001, sign test). Metal artefact index for the oral cavity in AIDR 3D/FIRST/SEMAR-A was 572.0/477.7/88.4, and significant differences were seen between each reconstruction algorithm (p < 0.0001, Wilcoxon signed-rank test). Conclusions: SEMAR-A could provide images with lesser metal artefact and better depiction of structures than AIDR 3D and FIRST.
引用
收藏
页数:7
相关论文
共 21 条
[1]   Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation [J].
Bamberg, Fabian ;
Dierks, Alexander ;
Nikolaou, Konstantin ;
Reiser, Maximilian F. ;
Becker, Christoph R. ;
Johnson, Thorsten R. C. .
EUROPEAN RADIOLOGY, 2011, 21 (07) :1424-1429
[2]   Artifacts in CT: Recognition and avoidance [J].
Barrett, JF ;
Keat, N .
RADIOGRAPHICS, 2004, 24 (06) :1679-1691
[3]   COMPUTED-TOMOGRAPHY (CT) AND MAGNETIC-RESONANCE-IMAGING (MRI) IN T-STAGE EVALUATION OF ORAL AND OROPHARYNGEAL CARCINOMAS [J].
BOOTZ, F ;
LENZ, M ;
SKALEJ, M ;
BONGERS, H .
CLINICAL OTOLARYNGOLOGY, 1992, 17 (05) :421-429
[4]   Model-Based Iterative Reconstruction (MBIR) for the Reduction of Metal Artifacts on CT [J].
Boudabbous, Sana ;
Arditi, Daniel ;
Paulin, Emilie ;
Syrogiannopoulou, Aphrodite ;
Becker, Christoph ;
Montet, Xavier .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (02) :380-385
[5]  
Chang YB, 2012, IEEE NUCL SCI CONF R, P3426
[6]   Peering through the glare: using dual-energy CT to overcome the problem of metal artefacts in bone radiology [J].
Coupal, Tyler M. ;
Mallinson, Paul I. ;
McLaughlin, Patrick ;
Nicolaou, Savvas ;
Munk, Peter L. ;
Ouellette, Hugue .
SKELETAL RADIOLOGY, 2014, 43 (05) :567-575
[7]   Analysis of metal artifact reduction tools for dental hardware in CT scans of the oral cavity: kVp, iterative reconstruction, dual-energy CT, metal artifact reduction software: does it make a difference? [J].
De Crop, An ;
Casselman, Jan ;
Van Hoof, Tom ;
Dierens, Melissa ;
Vereecke, Elke ;
Bossu, Nicolas ;
Pamplona, Jaime ;
D'Herde, Katharina ;
Thierens, Hubert ;
Bacher, Klaus .
NEURORADIOLOGY, 2015, 57 (08) :841-849
[8]   Metal artifact reduction using virtual monochromatic images for patients with pedicle screws implants on CT [J].
Dong, Yue ;
Shi, Ai Jun ;
Wu, Jian Lin ;
Wang, Ru Xin ;
Sun, Li Fei ;
Liu, Ai Lian ;
Liu, Yi Jun .
EUROPEAN SPINE JOURNAL, 2016, 25 (06) :1754-1763
[9]   A newly-developed metal artifact reduction algorithm improves the visibility of oral cavity lesions on 320-MDCT volume scans [J].
Funama, Yoshinori ;
Taguchi, Katsuyuki ;
Utsunomiya, Daisuke ;
Oda, Seitaro ;
Hirata, Kenichiro ;
Yuki, Hideaki ;
Kidoh, Masafumi ;
Hatemura, Masahiro ;
Yamashita, Yasuyuki .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (01) :66-71
[10]   Pseudoprogression of Glioblastoma after Chemo- and Radiation Therapy: Diagnosis by Using Dynamic Susceptibility-weighted Contrast-enhanced Perfusion MR Imaging with Ferumoxytol versus Gadoteridol and Correlation with Survival [J].
Gahramanov, Seymur ;
Muldoon, Leslie L. ;
Varallyay, Csanad G. ;
Li, Xin ;
Kraemer, Dale F. ;
Fu, Rongwei ;
Hamilton, Bronwyn E. ;
Rooney, William D. ;
Neuwelt, Edward A. .
RADIOLOGY, 2013, 266 (03) :842-852