Determination Of L-carnitine in food supplement formulations using ion-pair chromatography with indirect conductimetric detection

被引:23
作者
Kakou, A [1 ]
Megoulas, NC [1 ]
Koupparis, MA [1 ]
机构
[1] Univ Athens, Dept Chem, Analyt Chem Lab, GR-15771 Athens, Greece
关键词
L-carnitine; levocamitine; ion-pair chromatography; food supplement; indirect conductimetric detection;
D O I
10.1016/j.chroma.2005.02.021
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel method for the determination Of L-carnitine in food supplement formulations was developed and validated, using ion-pair chromatography with indirect conductimetric detection. The chromatographic method was based on a non-polar (C-18) column and an aqueous octanesulfonate (0.64 mM) eluent, acidified with trifluoroacetic acid (5.2 mM). The retention time was 5.4 min and the asymmetry factor 0.65. A linear calibration curve from 10 to 1000 mu g/ml (r = 0.99998), with a detection limit of 2.7 mu g/ml (25 RI injection volume), a repeatability %RSD of 0.8 (40 mu g/ml, it = 5) and reproducibility %RSD of 2.6 were achieved. The proposed method was applied for the determination of carnitine in oral solutions and capsules. No interference from excipients was found and the only pretreatment step required was the appropriate dilution with the mobile phase. Recovery from spiked samples was ranged from 97.7 to 99.7 % with a precision (%RSD, it = 3) of 0.01-2.1 %. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:209 / 215
页数:7
相关论文
共 25 条
[1]   CONVERSION OF BUTYROBETAINE TO CARNITINE IN RAT INVIVO [J].
BOHMER, T .
BIOCHIMICA ET BIOPHYSICA ACTA, 1974, 343 (03) :551-557
[2]   PHARMACOKINETIC CONSIDERATIONS FOR THE THERAPEUTIC USE OF CARNITINE IN HEMODIALYSIS-PATIENTS [J].
BRASS, EP .
CLINICAL THERAPEUTICS, 1995, 17 (02) :176-185
[3]  
BREMER J, 1962, J BIOL CHEM, V237, P3628
[4]  
CARTER AL, 1995, J CHILD NEUROL, V10, pS2
[5]   A D-carnitine dehydrogenase electrode for the assessment of enantiomeric purity of L-carnitine preparations [J].
Chen, ZQ ;
Warsinke, A ;
Gajovic, N ;
Grosse, S ;
Hu, J ;
Kleber, HP ;
Scheller, FW .
ANALYTICAL LETTERS, 2000, 33 (06) :1079-1089
[6]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND CAPILLARY ELECTROPHORESIS OF L-CARNITINE AND D-CARNITINE BY PRECOLUMN DIASTEREOMERIC DERIVATIZATION [J].
DEWITT, P ;
DEIAS, R ;
MUCK, S ;
GALLETTI, B ;
MELONI, D ;
CELLETTI, P ;
MARZO, A .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1994, 657 (01) :67-73
[7]   Enzymic flow injection determination of free L-carnitine in infant formulae [J].
Ferreira, IMPLVO ;
Macedo, MN ;
Ferreira, MA .
ANALYST, 1997, 122 (12) :1539-1541
[8]  
HADDAD PR, 1990, ION CHROMATOGRAPHY P, P124
[9]   CARNITINE SYNTHESIS IN RAT TISSUE-SLICES [J].
HAIGLER, HT ;
BROQUIST, HP .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1974, 56 (03) :676-681
[10]   Improved high-performance liquid chromatographic method for analysis of L-carnitine in pharmaceutical formulations [J].
He, GX ;
Dahl, T .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 23 (2-3) :315-321