EFFECT OF CHANNEL PRESSURE DIFFERENCE IN HEAT TRANSFER ENHANCEMENT IN MICRO-CHANNEL WITH SYNTHETIC JET

被引:0
作者
Lee, A. [1 ]
Reizes, J. A. [1 ]
Timchenko, V. [1 ]
Yeoh, G. H. [1 ,2 ]
机构
[1] Univ New South Wales, Sch Mech & Mfg Engn, Sydney, NSW 2052, Australia
[2] ANSTO, Menai, NSW 2234, Australia
来源
PROCEEDINGS OF CHT-12 - ICHMT INTERNATIONAL SYMPOSIUM ON ADVANCES IN COMPUTATIONAL HEAT TRANSFER | 2012年
关键词
MICRO-CHANNELS; FLOW;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A three-dimensional computational model has been developed to investigate the cooling of a microchip by micro-channels in which water is flowing and in which a synthetic jet generator has been installed at the mid-point of the channels. The synthetic jet operates at a fixed frequency and amplitude of the diaphragms while the pressure difference between the ends of the channels is varied. For a microchip with a constant thermal load, when the synthetic jet is not operating, because the flow rate in the channels increases as the pressure difference is raised, as would be expected, the maximum temperature in the wafer is reduced as the pressure difference is increased. As the result in this steady flow, the maximum temperature in the silicon wafer with a thermal load of 1 MWm(-2) is decreased by 11.3 K when the channel pressure difference is raised from 500 Pa to 1500 Pa. It is shown that when the synthetic jet is activated at a constant frequency and amplitude, the flow patterns in the channels are quite different at the two pressure differences. As a consequence, whilst the maximum temperature in the silicon wafer is lowered in each case below that prevailing when the flow is steady, after the 40th cycle of membrane oscillation the reductions in the maximum temperature in the silicon wafer are 9 K and 7.5 K below those in steady flow for with channel pressure differences of 500 Pa and 1500 Pa respectively. It follows that the reduction in temperature caused by a synthetic jet is lessened if the pressure difference between the ends of the channels is significantly increased. Therefore, the channel pressure difference and the synthetic jet parameters are equally important in determining the optimal operating condition.
引用
收藏
页码:897 / 915
页数:19
相关论文
共 8 条
[1]   Heat transfer enhancement in microchannels with cross-flow synthetic jets [J].
Chandratilleke, T. T. ;
Jagannatha, D. ;
Narayanaswamy, R. .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2010, 49 (03) :504-513
[2]   Micron-level actuators for thermal management of microelectronic devices [J].
Erbas, N. ;
Baysal, O. .
HEAT TRANSFER ENGINEERING, 2009, 30 (1-2) :138-147
[3]   Three-dimensional modelling of fluid flow and heat transfer in micro-channels with synthetic jet [J].
Lee, A. ;
Timchenko, V. ;
Yeoh, G. H. ;
Reizes, J. A. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (1-3) :198-213
[4]   Numerical Computation and Investigation of the Characteristics of Microscale Synthetic Jets [J].
Lee, Ann ;
Yeoh, Guan H. ;
Timchenko, Victoria ;
Reizes, John .
MODELLING AND SIMULATION IN ENGINEERING, 2011, 2011
[5]   EFFECT OF OPERATING FREQUENCY ON HEAT TRANSFER IN A MICROCHANNEL WITH SYNTHETIC JET [J].
Li, D. ;
Timchenko, V. ;
Reizes, J. A. ;
Leonardi, E. .
COMPUTATIONAL THERMAL SCIENCES, 2009, 1 (04) :361-383
[6]  
RHIE CM, 1983, AIAA J, V21, P1525, DOI 10.2514/3.8284
[8]   An evaluation of synthetic jets for heat transfer enhancement in air cooled micro-channels [J].
Timchenko, Victoria ;
Reizes, John ;
Leonardi, Eddie .
INTERNATIONAL JOURNAL OF NUMERICAL METHODS FOR HEAT & FLUID FLOW, 2007, 17 (03) :263-283